Your browser doesn't support javascript.
loading
Three-parameter shear wave inversion in MR elastography of incompressible transverse isotropic media: Application to in vivo lower leg muscles.
Guo, Jing; Hirsch, Sebastian; Scheel, Michael; Braun, Jürgen; Sack, Ingolf.
Afiliação
  • Guo J; Department of Radiology, Charité-Universitätsmedizin Berlin, Campus Charité Mitte, Berlin, Germany.
  • Hirsch S; Department of Radiology, Charité-Universitätsmedizin Berlin, Campus Charité Mitte, Berlin, Germany.
  • Scheel M; Department of Radiology, Charité-Universitätsmedizin Berlin, Campus Charité Mitte, Berlin, Germany.
  • Braun J; Institute of Medical Informatics, Charité-Universitätsmedizin Berlin, Campus Benjamin Franklin, Berlin, Germany.
  • Sack I; Department of Radiology, Charité-Universitätsmedizin Berlin, Campus Charité Mitte, Berlin, Germany.
Magn Reson Med ; 75(4): 1537-45, 2016 Apr.
Article em En | MEDLINE | ID: mdl-25988407
PURPOSE: To develop and demonstrate MR elastography (MRE) for the measurement of three independent viscoelastic constants of skeletal muscle according to the theory of linear elasticity of incompressible materials with transverse isotropy (TI). METHODS: Three-dimensional multifrequency MRE was applied to soleus, gastrocnemius, and tibialis anterior muscles in 10 healthy volunteers. The rotational wave fields were solved for complex-valued viscoelastic parameters µ12, µ13, and E3 corresponding to two shear moduli (within the planes of isotropy and symmetry of TI materials) and Young's modulus (along the principal fiber axis). RESULTS: Anisotropy was represented by the inequality µ12 < µ13 < 1/3E3 considering storage and loss properties of the soleus and gastrocnemius muscles, whereas storage shear moduli of tibialis were indistinguishable. Storage moduli were: 1.06 ± 0.12, 1.33 ± 0.10, 6.92 ± 0.95 kPa (soleus); 0.90 ± 0.11, 1.30 ± 0.15, 8.22 ± 1.37 kPa (gastrocnemius); 1.26 ± 0.16, 1.27 ± 0.11, 9.29 ± 1.42 kPa (tibialis), for µ12, µ13, and E3, respectively. The muscles were different in their µ12 and E3 values, whereas µ13 was less sensitive to the muscle type. Leg differences were observed in the soleus and gastrocnemius muscles. CONCLUSION: Recovery of the full elasticity tensor in incompressible TI materials is feasible by three-dimensional inversion of the time-harmonic shear wave equation. The method is potentially useful for the clinical evaluation of skeletal muscle anisotropy.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Músculo Esquelético / Imageamento Tridimensional / Técnicas de Imagem por Elasticidade / Perna (Membro) Tipo de estudo: Diagnostic_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Magn Reson Med Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Músculo Esquelético / Imageamento Tridimensional / Técnicas de Imagem por Elasticidade / Perna (Membro) Tipo de estudo: Diagnostic_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Magn Reson Med Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Alemanha