Your browser doesn't support javascript.
loading
Percutaneous adjustment method for transversely migrated spinal cord stimulation leads: a technical report.
Jeon, Sang Yoon; Ji, Jae Young; Yoo, Sie Hyeon; Chon, Jin Young; Jung, Sung Hoon; Moon, Ho Sik.
Afiliação
  • Jeon SY; Department of Anesthesiology and Pain Medicine, Cheju Halla General Hospital, Cheju, Korea.
  • Ji JY; Department of Anesthesiology and Pain Medicine, College of Medicine, Soonchunhyang University Cheonan Hospital, Cheonan, Korea.
  • Yoo SH; Department of Anesthesiology and Pain Medicine, College of Medicine, Soonchunhyang University Cheonan Hospital, Cheonan, Korea.
  • Chon JY; Department of Anesthesiology and Pain Medicine, Yeouido St. Mary's Hospital, College of Medicine, The Catholic University of Korea, 10 63-ro, Yeoungdeungpo-gu, Seoul, 150-713, Korea.
  • Jung SH; Department of Anesthesiology and Pain Medicine, Yeouido St. Mary's Hospital, College of Medicine, The Catholic University of Korea, 10 63-ro, Yeoungdeungpo-gu, Seoul, 150-713, Korea.
  • Moon HS; Department of Anesthesiology and Pain Medicine, Yeouido St. Mary's Hospital, College of Medicine, The Catholic University of Korea, 10 63-ro, Yeoungdeungpo-gu, Seoul, 150-713, Korea. mhsjshgma@gmail.com.
J Anesth ; 29(6): 953-6, 2015 Dec.
Article em En | MEDLINE | ID: mdl-26094104
ABSTRACT
Lead migration is the most common complication of spinal cord stimulation (SCS). However, the only corrective method for lead migration is revision surgery, which may cause additional complications. Here, we describe a new technique for adjusting a transversely migrated SCS lead. The medical records of four patients diagnosed with complex regional pain syndrome (n = 3) or failed back surgery syndrome (n = 1) who underwent implantation of percutaneous leads for SCS were retrospectively reviewed. Transverse lead migration was diagnosed radiographically after patients reported recurrence of pain or numbness in treated sites. The guide wire from the SCS implant kit was bent and inserted into the target epidural space using a 14-gauge Tuohy needle. When the guide wire contacted the migrated SCS lead, they were advanced to the correct location under C-arm guidance. After re-adjustment of the SCS lead, good coverage of the electrical stimulation was confirmed. Patients were followed for 9-19 months and they reported satisfactory pain relief and good electrical coverage after adjusting the SCS lead. Here, we describe a new technique for adjusting a transversely migrated SCS lead using a percutaneous epidural approach as a simple, safe, and cost-effective alternative to revision surgery.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Eletrodos Implantados / Síndrome Pós-Laminectomia / Estimulação da Medula Espinal Tipo de estudo: Guideline / Observational_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: J Anesth Assunto da revista: ANESTESIOLOGIA Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Eletrodos Implantados / Síndrome Pós-Laminectomia / Estimulação da Medula Espinal Tipo de estudo: Guideline / Observational_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: J Anesth Assunto da revista: ANESTESIOLOGIA Ano de publicação: 2015 Tipo de documento: Article