Your browser doesn't support javascript.
loading
The Importance of Hemorheology and Patient Anatomy on the Hemodynamics in the Inferior Vena Cava.
Aycock, Kenneth I; Campbell, Robert L; Lynch, Frank C; Manning, Keefe B; Craven, Brent A.
Afiliação
  • Aycock KI; Applied Research Laboratory, The Pennsylvania State University, University Park, PA, USA.
  • Campbell RL; Department of Biomedical Engineering, The Pennsylvania State University, University Park, PA, USA.
  • Lynch FC; Applied Research Laboratory, The Pennsylvania State University, University Park, PA, USA.
  • Manning KB; Department of Mechanical and Nuclear Engineering, The Pennsylvania State University, University Park, PA, USA.
  • Craven BA; Department of Surgery, Penn State Hershey Medical Center, Hershey, PA, USA.
Ann Biomed Eng ; 44(12): 3568-3582, 2016 12.
Article em En | MEDLINE | ID: mdl-27272211
ABSTRACT
Inferior vena cava (IVC) filters have been used for nearly half a century to prevent pulmonary embolism in at-risk patients. However, complications with IVC filters remain common. In this study, we investigate the importance of considering the hemorheological and morphological effects on IVC hemodynamics by simulating Newtonian and non-Newtonian blood flow in three IVC models with varying levels of geometric idealization. Partial occlusion by an IVC filter and a thrombus is also considered. More than 99% of the infrarenal IVC volume is found to contain flow in the nonlinear region of the shear rate-viscosity curve for blood (less than 100 s-1) in the unoccluded IVCs. Newtonian simulations performed using the asymptotic viscosity for blood over-predict the non-Newtonian Reynolds numbers by more than a factor of two and under-predict the mean wall shear stress (WSS) by 28-54%. Agreement with the non-Newtonian simulations is better using a characteristic viscosity, but local WSS errors are still large (up to 50%) in the partially occluded cases. Secondary flow patterns in the IVC also depend on the viscosity model and IVC morphological complexity. Non-Newtonian simulations required only a marginal increase in computational expense compared with the Newtonian simulations. We recommend that future studies of IVC hemodynamics consider the effects of hemorheology and IVC morphology when accurate predictions of WSS and secondary flow features are desired.
Assuntos
Palavras-chave
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Trombose / Veia Cava Inferior / Filtros de Veia Cava / Hemorreologia / Modelos Cardiovasculares Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: Ann Biomed Eng Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Estados Unidos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Trombose / Veia Cava Inferior / Filtros de Veia Cava / Hemorreologia / Modelos Cardiovasculares Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: Ann Biomed Eng Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Estados Unidos