Your browser doesn't support javascript.
loading
Multidimensional Normalization to Minimize Plate Effects of Suspension Bead Array Data.
Hong, Mun-Gwan; Lee, Woojoo; Nilsson, Peter; Pawitan, Yudi; Schwenk, Jochen M.
Afiliação
  • Hong MG; Affinity Proteomics, Science for Life Laboratory, School of Biotechnology, KTH - Royal Institute of Technology , Solna 171 65, Sweden.
  • Lee W; Department of Statistics, Inha University , Incheon 22212, Korea.
  • Nilsson P; Affinity Proteomics, Science for Life Laboratory, School of Biotechnology, KTH - Royal Institute of Technology , Solna 171 65, Sweden.
  • Pawitan Y; Department of Medical Epidemiology and Biostatistics, Karolinska Institutet , Stockholm 171 77, Sweden.
  • Schwenk JM; Affinity Proteomics, Science for Life Laboratory, School of Biotechnology, KTH - Royal Institute of Technology , Solna 171 65, Sweden.
J Proteome Res ; 15(10): 3473-3480, 2016 10 07.
Article em En | MEDLINE | ID: mdl-27570895
Enhanced by the growing number of biobanks, biomarker studies can now be performed with reasonable statistical power by using large sets of samples. Antibody-based proteomics by means of suspension bead arrays offers one attractive approach to analyze serum, plasma, or CSF samples for such studies in microtiter plates. To expand measurements beyond single batches, with either 96 or 384 samples per plate, suitable normalization methods are required to minimize the variation between plates. Here we propose two normalization approaches utilizing MA coordinates. The multidimensional MA (multi-MA) and MA-loess both consider all samples of a microtiter plate per suspension bead array assay and thus do not require any external reference samples. We demonstrate the performance of the two MA normalization methods with data obtained from the analysis of 384 samples including both serum and plasma. Samples were randomized across 96-well sample plates, processed, and analyzed in assay plates, respectively. Using principal component analysis (PCA), we could show that plate-wise clusters found in the first two components were eliminated by multi-MA normalization as compared with other normalization methods. Furthermore, we studied the correlation profiles between random pairs of antibodies and found that both MA normalization methods substantially reduced the inflated correlation introduced by plate effects. Normalization approaches using multi-MA and MA-loess minimized batch effects arising from the analysis of several assay plates with antibody suspension bead arrays. In a simulated biomarker study, multi-MA restored associations lost due to plate effects. Our normalization approaches, which are available as R package MDimNormn, could also be useful in studies using other types of high-throughput assay data.
Assuntos
Palavras-chave
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Separação Imunomagnética / Análise de Componente Principal / Proteômica Tipo de estudo: Clinical_trials / Prognostic_studies Limite: Humans Idioma: En Revista: J Proteome Res Assunto da revista: BIOQUIMICA Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Suécia
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Separação Imunomagnética / Análise de Componente Principal / Proteômica Tipo de estudo: Clinical_trials / Prognostic_studies Limite: Humans Idioma: En Revista: J Proteome Res Assunto da revista: BIOQUIMICA Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Suécia