Your browser doesn't support javascript.
loading
Silicone Foley's catheter as an effective alternative to Hunter's rod in staged flexor tendon reconstruction of the hand.
Ahmad, Tawheed; Bashir, Sheikh Adil; Zaroo, Mohammad Inam; Wani, Adil Hafeez; Rashid, Saima; Jan, Summaira.
Afiliação
  • Ahmad T; Department of Plastic and Reconstructive Surgery, Sher-I-Kashmir Institute of Medical Sciences, Srinagar, Jammu and Kashmir, India.
  • Bashir SA; Department of Plastic and Reconstructive Surgery, Sher-I-Kashmir Institute of Medical Sciences, Srinagar, Jammu and Kashmir, India.
  • Zaroo MI; Department of Plastic and Reconstructive Surgery, Sher-I-Kashmir Institute of Medical Sciences, Srinagar, Jammu and Kashmir, India.
  • Wani AH; Department of Plastic and Reconstructive Surgery, Sher-I-Kashmir Institute of Medical Sciences, Srinagar, Jammu and Kashmir, India.
  • Rashid S; Department of Plastic and Reconstructive Surgery, Sher-I-Kashmir Institute of Medical Sciences, Srinagar, Jammu and Kashmir, India.
  • Jan S; Department of Plastic and Reconstructive Surgery, Sher-I-Kashmir Institute of Medical Sciences, Srinagar, Jammu and Kashmir, India.
Indian J Plast Surg ; 49(3): 322-328, 2016.
Article em En | MEDLINE | ID: mdl-28216811
ABSTRACT
CONTEXT Staged flexor tendon reconstruction is most suitable treatment method for extensive zone II tendon injuries. The Hunter's rod used in this procedure is costly and not easily available, which adds to the miseries of both patients as well as treating surgeon.

AIMS:

The aim of this study is to evaluate the results of staged zone II flexor tendon repair using silicone Foley's catheter as a cheaper and readily available alternative to Hunter's rod. SETTINGS AND

DESIGN:

This was a prospective study. MATERIALS AND

METHODS:

Seventy digits in 35 patients were treated by the staged flexor tendon reconstruction using silicone Foley's catheter in place of Hunter's rod, and the patients were followed for an average period of 18 months. Early controlled motion exercise protocol was instituted in all cases.

RESULTS:

As per the Strickland scale, total active motion obtained was excellent in 70%, good in 20%, fair in 7.1% and poor in 2.9% of patients.

CONCLUSIONS:

Silicone Foley's catheter is cheaper, easily available and an effective alternative to Hunter's rod in staged flexor tendon reconstruction procedure, yielding high rates of excellent and good results with fewer complications.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Guideline / Observational_studies Idioma: En Revista: Indian J Plast Surg Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Índia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Guideline / Observational_studies Idioma: En Revista: Indian J Plast Surg Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Índia