Your browser doesn't support javascript.
loading
Rapid whole-brain gray matter imaging using single-slab three-dimensional dual-echo fast spin echo: A feasibility study.
Lee, Hyunyeol; Kim, Eung Yeop; Sohn, Chul-Ho; Park, Jaeseok.
Afiliação
  • Lee H; Department of Biomedical Engineering, Sungkyunkwan University, Suwon, Republic of Korea.
  • Kim EY; Department of Radiology, Gachon University Gil Medical Center, Incheon, Republic of Korea.
  • Sohn CH; Department of Radiology, Seoul National University Hospital, Seoul, Republic of Korea.
  • Park J; Department of Biomedical Engineering, Sungkyunkwan University, Suwon, Republic of Korea.
Magn Reson Med ; 78(5): 1691-1699, 2017 11.
Article em En | MEDLINE | ID: mdl-28921660
PURPOSE: To achieve rapid, high resolution whole-brain gray matter (GM) imaging by developing a novel, single-slab three-dimensional dual-echo fast-spin-echo pulse sequence and GM-selective reconstruction. METHODS: Unlike conventional GM imaging that uses time-consuming double-inversion-recovery preparation, the proposed pulse sequence was designed to have two split portions along the echo train, in which the first half was dedicated to yield short inversion recovery (IR)-induced white matter suppression and variable-flip-angle-induced two-step GM signal evolution while the second half cerebrospinal fluid-only signals. Multi-step variable-flip-angle schedules and sampling reordering were optimized to yield high GM signals while balancing cerebrospinal fluid signals between ECHOes. GM-selective images were then reconstructed directly from the weighted subtraction between ECHOes by solving a sparse signal recovery problem. In vivo studies were performed to validate the effectiveness of the proposed method over conventional double-inversion-recovery. RESULTS: The proposed method, while achieving one millimeter isotropic, whole-brain GM imaging within 5.5 min, showed superior performance than conventional double-inversion-recovery in producing GM-only images without apparent artifacts and noise. CONCLUSION: We successfully demonstrated the feasibility of the proposed method in achieving whole-brain GM imaging in a clinically acceptable imaging time. The proposed method is expected to be a promising alternative to conventional double-inversion-recovery in clinical applications. Magn Reson Med 78:1691-1699, 2017. © 2017 International Society for Magnetic Resonance in Medicine.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Imageamento Tridimensional / Substância Cinzenta Limite: Humans Idioma: En Revista: Magn Reson Med Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Imageamento Tridimensional / Substância Cinzenta Limite: Humans Idioma: En Revista: Magn Reson Med Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2017 Tipo de documento: Article