Your browser doesn't support javascript.
loading
Diagnosis of Mesiodistal Vertical Root Fractures in Teeth with Metal Posts: Influence of Applying Filters in Cone-beam Computed Tomography Images at Different Resolutions.
De Martin E Silva, Débora; Campos, Celso Neiva; Pires Carvalho, Antônio Carlos; Devito, Karina Lopes.
Afiliação
  • De Martin E Silva D; School of Dentistry, Federal University of Juiz de Fora, Juiz de Fora, Brazil.
  • Campos CN; Department of Dental Clinics, School of Dentistry, Federal University of Juiz de Fora, Juiz de Fora, Brazil.
  • Pires Carvalho AC; Department of Radiology, School of Medicine, Federal University of Rio de Janeiro, Rio de Janeiro, RJ, Brazil.
  • Devito KL; Department of Dental Clinics, School of Dentistry, Federal University of Juiz de Fora, Juiz de Fora, Brazil. Electronic address: karina.devito@ufjf.edu.br.
J Endod ; 44(3): 470-474, 2018 Mar.
Article em En | MEDLINE | ID: mdl-29153985
ABSTRACT

INTRODUCTION:

The aim of this article was to evaluate the influence of applying filters in cone-beam computed tomography (CBCT) images at different resolutions. These CBCT images were obtained for diagnosing mesiodistal vertical root fractures (VRFs) in teeth with metal posts.

METHODS:

Forty teeth were treated endodontically, and 20 received metal posts. Ten teeth without posts and 10 teeth with posts were subjected to VRF in the mesiodistal direction. The sample was submitted to periapical radiographs and CBCT exams with a voxel of 0.25 and 0.30 mm. To reduce the influence of the metal artifact in the CT images, the teeth were evaluated with and without the application of filters ("Sharpen" and "Hard"). The images were evaluated by 2 radiologists who identified the presence of VRF. Accuracy values (receiver operating characteristic curves) for the different variables were compared by using analysis of variance and t test.

RESULTS:

No difference was observed between images with and without filter application (P > .05). Images obtained with a 0.25-mm voxel were more accurate (P < .05). The presence of the metal post reduced the accuracy of the diagnosis of VRF (P < .05), and the CBCT images showed superior results compared with periapical radiographs (P < .05).

CONCLUSIONS:

The presence of a metal post and the voxel size significantly interfere with the diagnosis of VRF. Despite the formation of metal artifacts associated with metallic cores, applying filters did not improve the diagnosis. For mesiodistal VRF, the CBCT images are superior to the periapical radiographs.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fraturas dos Dentes / Raiz Dentária / Coroas / Tomografia Computadorizada de Feixe Cônico Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Revista: J Endod Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Brasil

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fraturas dos Dentes / Raiz Dentária / Coroas / Tomografia Computadorizada de Feixe Cônico Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Revista: J Endod Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Brasil