Impact of procedure-related conduction disturbances after transcatheter aortic valve implantation on myocardial performance and survival evaluated by conventional and speckle tracking echocardiography.
Echocardiography
; 35(5): 621-631, 2018 05.
Article
em En
| MEDLINE
| ID: mdl-29437242
OBJECTIVES: Although procedure-related new cardiac conduction disturbances (CCDs) remain an important issue in transcatheter aortic valve implantation (TAVI), their effect on myocardial function and overall patient outcome remains unclear. The goal of this study was to analyze the influence of procedure-related CCDs on systolic and diastolic LV performance and on patient survival after TAVI. METHODS AND RESULTS: Ninety-five patients who underwent TAVI for severe symptomatic aortic stenosis (AS) and had a complete follow-up were evaluated with respect to procedure-related CCDs. Left ventricular (LV) performance was measured using standard echocardiographic parameters and speckle tracking analysis. Survival was assessed during longer-term follow-up (mean: 29.1 ± 16.9 months). After TAVI, the improvement of global LV function expressed as ejection fraction (LVEF; from 45.5 ± 10.0 to 47.8 ± 13.9%, P = .13) was not significant. New CCDs were found in 35.7% of TAVI recipients. A comparison between patients with and without new CCDs showed that LV systolic function improved in those without CCDs, while it tended to deteriorate in patients with CCDs (change in LVEF: 5.5 ± 12.3% vs -4.9% ± 11.5%, P = .001; change in global longitudinal strain (GLS): -1.1 ± 4.6% vs 1.2 ± 4.5%, P = .01). Changes in diastolic function did not differ significantly between the groups (changes in transmitral E/A-ratio: -0.3 ± 0.6 vs -0.5 ± 0.5, P = .1). Kaplan-Meier survival analysis revealed no significant differences between the two cohorts (P = .795). CONCLUSION: Procedure-related conduction abnormalities after TAVI lead to an LBBB-related dyssynchrony with impairment of LV performance but not of overall survival.
Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Valva Aórtica
/
Estenose da Valva Aórtica
/
Próteses Valvulares Cardíacas
/
Ecocardiografia
/
Função Ventricular Esquerda
/
Substituição da Valva Aórtica Transcateter
/
Contração Miocárdica
Tipo de estudo:
Diagnostic_studies
/
Observational_studies
/
Prognostic_studies
Limite:
Aged80
/
Female
/
Humans
/
Male
Idioma:
En
Revista:
Echocardiography
Assunto da revista:
CARDIOLOGIA
/
DIAGNOSTICO POR IMAGEM
Ano de publicação:
2018
Tipo de documento:
Article
País de afiliação:
Alemanha