Your browser doesn't support javascript.
loading
New surgical approach for intrascleral fixation using an intraocular lens with hook-shaped haptics.
Yoshida, Norihiko; Kojima, Takashi; Yokoyama, Sho; Horai, Rie; Ichikawa, Kazuo.
Afiliação
  • Yoshida N; From the Departments of Ophthalmology, Japanese Red Cross Gifu Hospital (Yoshida), Gifu, Keio University School of Medicine (Kojima), Tokyo, and Japan Community Healthcare Organization Chukyo Hospital (Yokoyama), and Chukyo Medical Co. Inc. (Horai), and Chukyo Eye Clinic (Ichikawa), Nagoya, Japan.
  • Kojima T; From the Departments of Ophthalmology, Japanese Red Cross Gifu Hospital (Yoshida), Gifu, Keio University School of Medicine (Kojima), Tokyo, and Japan Community Healthcare Organization Chukyo Hospital (Yokoyama), and Chukyo Medical Co. Inc. (Horai), and Chukyo Eye Clinic (Ichikawa), Nagoya, Japan. E
  • Yokoyama S; From the Departments of Ophthalmology, Japanese Red Cross Gifu Hospital (Yoshida), Gifu, Keio University School of Medicine (Kojima), Tokyo, and Japan Community Healthcare Organization Chukyo Hospital (Yokoyama), and Chukyo Medical Co. Inc. (Horai), and Chukyo Eye Clinic (Ichikawa), Nagoya, Japan.
  • Horai R; From the Departments of Ophthalmology, Japanese Red Cross Gifu Hospital (Yoshida), Gifu, Keio University School of Medicine (Kojima), Tokyo, and Japan Community Healthcare Organization Chukyo Hospital (Yokoyama), and Chukyo Medical Co. Inc. (Horai), and Chukyo Eye Clinic (Ichikawa), Nagoya, Japan.
  • Ichikawa K; From the Departments of Ophthalmology, Japanese Red Cross Gifu Hospital (Yoshida), Gifu, Keio University School of Medicine (Kojima), Tokyo, and Japan Community Healthcare Organization Chukyo Hospital (Yokoyama), and Chukyo Medical Co. Inc. (Horai), and Chukyo Eye Clinic (Ichikawa), Nagoya, Japan.
J Cataract Refract Surg ; 44(2): 129-133, 2018 Feb.
Article em En | MEDLINE | ID: mdl-29502861
We report a new surgical technique of intrascleral posterior chamber intraocular lens (PC IOL) fixation using a newly developed hook-shaped haptic IOL (NX-70CH) and a 25-gauge loop-shaped haptic manipulator. Previous techniques of intrascleral PC IOL fixation had 2 major technical challenges; that is, externalization of the haptic and fixation of the haptic into the scleral tunnel. The new IOL and manipulator can facilitate externalization and secure fixation of the IOL haptic and can be used for suture fixation or implantation in the capsular bag in cases with presumed subluxated lens.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Desenho de Prótese / Esclera / Implante de Lente Intraocular / Lentes Intraoculares Tipo de estudo: Observational_studies Limite: Humans Idioma: En Revista: J Cataract Refract Surg Assunto da revista: OFTALMOLOGIA Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Desenho de Prótese / Esclera / Implante de Lente Intraocular / Lentes Intraoculares Tipo de estudo: Observational_studies Limite: Humans Idioma: En Revista: J Cataract Refract Surg Assunto da revista: OFTALMOLOGIA Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Japão