Your browser doesn't support javascript.
loading
Balloon Guided Cement Augmentation of Iliosacral Screws in the Treatment of Insufficiency Fractures of the Sacrum - Description of a New Method and Preliminary Results.
Sandmann, G H; Stöckle, U; Freude, T; Stuby, F M.
Afiliação
  • Sandmann GH; BG Unfallklinik Tuebingen, Eberhard-Karls-Universitaet Tuebingen, Germany.
Acta Chir Orthop Traumatol Cech ; 85(2): 85-88, 2018.
Article em En | MEDLINE | ID: mdl-30295592
PURPOSE OF THE STUDY Fragility fractures of the pelvic ring in the elderly population are a serious problem in orthopaedics. The treatment options range from conservative treatment to diverse operative options. We present a balloon guided new technique of implanting cement augmented screws aiming at improved implant anchorage and reduced cement leakage. MATERIAL AND METHODS We describe a new technique of balloon- guided cement augmented iliosacral screws. After the balloon has been insufflated and contrast medium has been instillated for leakage detection, iliosacral screws can safely be placed with a relevant cement depot. RESULTS All patients (n = 8) treated in this way were allowed to weight bear on both legs and mobilisation was tolerated the next day after surgery. In the post-operative controls including X-ray and CT scan we noticed no cement leakage. Pain level as measured by the visual analog scale was significantly reduced to pre- surgery (mean 7.6 pre-operatively, mean 2.5 postoperatively). In addition pain medication could be reduced gradually soon after surgery. CONCLUSIONS The described procedure to address fragility fractures of the pelvic ring is a safe and easy to handle method. There are three advantages: First the osteoporotic S1 vertebral body can by stabilised by the amount of cement; second the cement leakage can be prevented by the balloon-compaction of the cancellous bone and the possibility to control the created cavity with contrast medium; third the bone - screw interface is much stronger compared to other procedures and is biomechanically superior against vertical shear stress. In contrast to sacroplasty, the cement application is guided by the previous use of a balloon. Key words:pelvic ring, fragility fracture, osteoporosis, elderly.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Sacro / Cimentos Ósseos / Parafusos Ósseos / Fraturas da Coluna Vertebral / Fraturas por Osteoporose / Fixação Interna de Fraturas Tipo de estudo: Diagnostic_studies Limite: Aged / Aged80 / Humans Idioma: En Revista: Acta Chir Orthop Traumatol Cech Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Alemanha
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Sacro / Cimentos Ósseos / Parafusos Ósseos / Fraturas da Coluna Vertebral / Fraturas por Osteoporose / Fixação Interna de Fraturas Tipo de estudo: Diagnostic_studies Limite: Aged / Aged80 / Humans Idioma: En Revista: Acta Chir Orthop Traumatol Cech Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Alemanha