Your browser doesn't support javascript.
loading
PEGylated BF2-Azadipyrromethene (NIR-AZA) fluorophores, for intraoperative imaging.
Wu, Dan; Daly, Harrison C; Conroy, Emer; Li, Bo; Gallagher, William M; Cahill, Ronan A; O'Shea, Donal F.
Afiliação
  • Wu D; Department of Chemistry, RCSI, 123 St. Stephen's Green, Dublin 2, Ireland.
  • Daly HC; Department of Chemistry, RCSI, 123 St. Stephen's Green, Dublin 2, Ireland.
  • Conroy E; School of Biomolecular and Biomedical Science, Conway Institute, University College Dublin, Belfield, Dublin 4, Ireland.
  • Li B; School of Biomolecular and Biomedical Science, Conway Institute, University College Dublin, Belfield, Dublin 4, Ireland.
  • Gallagher WM; School of Biomolecular and Biomedical Science, Conway Institute, University College Dublin, Belfield, Dublin 4, Ireland.
  • Cahill RA; Department of Surgery, Mater Misericordiae University Hospital, and Section of Surgery and Surgical Sciences, School of Medicine, University College Dublin, Ireland.
  • O'Shea DF; Department of Chemistry, RCSI, 123 St. Stephen's Green, Dublin 2, Ireland. Electronic address: donalfoshea@rcsi.ie.
Eur J Med Chem ; 161: 343-353, 2019 Jan 01.
Article em En | MEDLINE | ID: mdl-30368132
Clinical imaging utilising near-infrared fluorescence is growing as an intraoperative aid for the decision-making processes during complex surgical procedures. Existing uses include perfusion assessment and lymph node identification with many new applications currently being proposed and developed. While imaging hardware and software have significantly progressed in recent times, suitable NIR-fluorophores remain a limiting factor. In this report, we describe the design, synthesis, photophysical characterization and in vivo imaging assessment of new PEGylated NIR-fluorophores based on the BF2-azadipyrromethene fluorophore class. The synthetic route includes PEGylation as the final step, thereby allowing routine access to derivatives substituted with different molecular weights of PEG. Absorption and emission wavelength maxima in PBS lie at 690 and 720 nm respectively with quantum yields over 12%. They show excellent photostability and no light induced singlet oxygen production. A time-course of NIR-fluorescence imaging, post i.v. administration, in BALB/c mice showed a rapid and preferential accumulation in the renal excretion pathway within 20 min, indicative of potential clinical usage for intraoperative identification of vial structures along this pathway. Assessment with clinical imaging equipment showed the NIR-AZA fluorophores to be wavelength compatible and brighter than currently used methylene blue (MB), and that they have the ability to be imaged simultaneously with indocyanine green (ICG) offering a potential for dual colour clinical imaging.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Polietilenoglicóis / Porfobilinogênio / Compostos Aza / Neoplasias da Mama / Compostos de Boro / Imagem Óptica / Corantes Fluorescentes Tipo de estudo: Prognostic_studies Limite: Animals / Female / Humans Idioma: En Revista: Eur J Med Chem Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Irlanda

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Polietilenoglicóis / Porfobilinogênio / Compostos Aza / Neoplasias da Mama / Compostos de Boro / Imagem Óptica / Corantes Fluorescentes Tipo de estudo: Prognostic_studies Limite: Animals / Female / Humans Idioma: En Revista: Eur J Med Chem Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Irlanda