Your browser doesn't support javascript.
loading
UTE T2* mapping of tendinopathic patellar tendons: an MRI reproducibility study.
Agergaard, Anne-Sofie; Malmgaard-Clausen, Nikolaj M; Svensson, Rene B; Nybing, Janus D; Boesen, Mikael; Kjaer, Michael; Magnusson, S Peter; Hansen, Philip.
Afiliação
  • Agergaard AS; Institute of Sports Medicine Copenhagen, Department of Orthopedic Surgery, Bispebjerg and Frederiksberg Hospital, Copenhagen, Denmark.
  • Malmgaard-Clausen NM; Center for Healthy Aging, Faculty of Health Sciences, University of Copenhagen, Copenhagen, Denmark.
  • Svensson RB; Department of Physical and Occupational Therapy, Bispebjerg and Frederiksberg Hospital, Copenhagen, Denmark.
  • Nybing JD; Institute of Sports Medicine Copenhagen, Department of Orthopedic Surgery, Bispebjerg and Frederiksberg Hospital, Copenhagen, Denmark.
  • Boesen M; Center for Healthy Aging, Faculty of Health Sciences, University of Copenhagen, Copenhagen, Denmark.
  • Kjaer M; Institute of Sports Medicine Copenhagen, Department of Orthopedic Surgery, Bispebjerg and Frederiksberg Hospital, Copenhagen, Denmark.
  • Magnusson SP; Center for Healthy Aging, Faculty of Health Sciences, University of Copenhagen, Copenhagen, Denmark.
  • Hansen P; Department of Radiology, Copenhagen University Hospital, Bispebjerg and Frederiksberg, Copenhagen, Denmark.
Acta Radiol ; 62(2): 215-224, 2021 Feb.
Article em En | MEDLINE | ID: mdl-32340475
ABSTRACT

BACKGROUND:

There is currently a lack of imaging modalities that can be used as a sensitive measure in tendinopathy. Recent findings suggest the applicability of ultra-short echo time (UTE) magnetic resonance imaging (MRI) T2* mapping in tendons, but the reproducibility remains unknown.

PURPOSE:

To evaluate test-retest reproducibility of UTE MRI T2* mapping of tendinopathic patellar tendons and to evaluate the intra- and inter-observer reproducibility of the measurement. MATERIAL AND

METHODS:

Fifteen patients with chronic patellar tendinopathy were evaluated with UTE MRI twice in a 3.0-T scanner on the same day. Manual segmentation of the patellar tendon was performed by two blinded investigators and automated T2*map reconstruction was performed in custom-made software.

RESULTS:

There was a significant and numerically small difference in test-retest T2* values (T2*meandiff = 0.06 ± 0.07 ms ≈ 3.7%; P = 0.006) with an ICC = 0.91 (95% confidence interval [CI] 0.58-0.98; typical error of 3.0%). The intra- and inter-observer reproducibility showed no significant bias (P = 0.493 and P = 0.052), and generally substantial reproducibility was demonstrated for T2* (intra-observer ICC = 0.99; 95% CI 0.98-1.00 and inter-observer ICC = 0.99; 95% CI 0.96-1.00, and typical error 1.3% and 1.3%, respectively).

CONCLUSION:

These data demonstrate a small bias between repeated measurements for UTE T2*, but with a very low associated mean difference (3.7%) between the two tests. The high ICC values and low typical error % demonstrate reproducibility of repeated T2*-mapping sessions. Further, the method showed substantial intra- and inter-observer reproducibility for T2* values proving feasibility for use of UTE T2* mapping in research and clinical practice.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Interpretação de Imagem Assistida por Computador / Ligamento Patelar / Tendinopatia Tipo de estudo: Guideline / Observational_studies Limite: Adult / Humans / Male Idioma: En Revista: Acta Radiol Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Dinamarca

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Interpretação de Imagem Assistida por Computador / Ligamento Patelar / Tendinopatia Tipo de estudo: Guideline / Observational_studies Limite: Adult / Humans / Male Idioma: En Revista: Acta Radiol Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Dinamarca