Your browser doesn't support javascript.
loading
Axillary vein access for permanent pacemaker and implantable cardioverter defibrillator implantation: Fluoroscopy compared to ultrasound.
Migliore, Federico; Fais, Luisa; Vio, Riccardo; De Lazzari, Manuel; Zorzi, Alessandro; Bertaglia, Emanuele; Iliceto, Sabino.
Afiliação
  • Migliore F; Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padova, Padova, Italy.
  • Fais L; Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padova, Padova, Italy.
  • Vio R; Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padova, Padova, Italy.
  • De Lazzari M; Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padova, Padova, Italy.
  • Zorzi A; Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padova, Padova, Italy.
  • Bertaglia E; Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padova, Padova, Italy.
  • Iliceto S; Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padova, Padova, Italy.
Pacing Clin Electrophysiol ; 43(6): 566-572, 2020 06.
Article em En | MEDLINE | ID: mdl-32394452
BACKGROUND: Axillary vein access (AVA) using fluoroscopic landmarks is an effective and safe approach for cardiac implantable electronic devices (CIEDs) implantation. However, it may result in a higher radiation exposure. Ultrasound-guided axillary access (USAA) is an effective alternative technique to conventional subclavian access for CIEDs implantation. Studies comparing USAA and AVA using fluoroscopic landmarks are lacking. The purpose of this study was to compare the safety, efficacy, and radiation exposure data of the USAA approach with the AVA using fluoroscopic landmarks. METHODS: The study population included 95 consecutive patients (61% male, median age 78 years [71-85 years]) referred for CIEDs implantation using AVA with fluoroscopic landmark (n = 46) or USAA (n = 49). Baseline characteristics and radiation exposure data (Air-Kerma [mGy], DAP [Gy-cm2 ], fluoroscopy time [seconds], and X-rays emission time [seconds]) were compared according to the technique used for the AVA. RESULTS: Axillary vein was successfully accessed in 45 of 49 (92%) patients using ultrasound and in 42 of 46 (91%) patients using fluoroscopic landmarks (P = 1.00). Air-Kerma, DAP, fluoroscopy time, and X-rays emission time were shorter for USAA group compared with AVA using fluoroscopic landmarks (11 mGy [8-20] vs 37 mGy [24-81], P < .00001; 3 Gy-cm2 [2-5] vs 10 Gy-cm2 [6-16], P < .00001; 97 seconds [62-163] vs 271 seconds [185-365], P < .00001; and 7 seconds [4-10] vs 21 seconds [13-39], P < .00001). There were no significant differences between the two groups in median implant procedure time (P = .55). We did not encounter any acute or long-term complications in both groups. CONCLUSIONS: Ultrasound-guided axillary vein cannulation for CIEDs implantation is a feasible and safe alternative approach and offers a significant reduction in fluoroscopy times without increasing procedural time.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Marca-Passo Artificial / Veia Axilar / Fluoroscopia / Desfibriladores Implantáveis / Ultrassonografia de Intervenção / Implantação de Prótese / Cirurgia Assistida por Computador Tipo de estudo: Observational_studies Limite: Aged / Aged80 / Female / Humans / Male Idioma: En Revista: Pacing Clin Electrophysiol Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Itália

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Marca-Passo Artificial / Veia Axilar / Fluoroscopia / Desfibriladores Implantáveis / Ultrassonografia de Intervenção / Implantação de Prótese / Cirurgia Assistida por Computador Tipo de estudo: Observational_studies Limite: Aged / Aged80 / Female / Humans / Male Idioma: En Revista: Pacing Clin Electrophysiol Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Itália