Your browser doesn't support javascript.
loading
Association between intraocular lens diopter and posterior capsular opacification.
Hecht, Idan; Dubinsky-Pertzov, Biana; Karesvuo, Petteri; Achiron, Asaf; Tuuminen, Raimo.
Afiliação
  • Hecht I; Helsinki Retina Research Group, University of Helsinki, Helsinki, Finland.
  • Dubinsky-Pertzov B; Department of Ophthalmology, Shamir Medical Center and Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel.
  • Karesvuo P; Department of Ophthalmology, Shamir Medical Center and Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel.
  • Achiron A; Helsinki Retina Research Group, University of Helsinki, Helsinki, Finland.
  • Tuuminen R; Department of Ophthalmology, Helsinki University Hospital, Helsinki, Finland.
Clin Exp Ophthalmol ; 48(7): 889-894, 2020 09.
Article em En | MEDLINE | ID: mdl-32639048
ABSTRACT
IMPORTANCE Posterior capsular opacification (PCO) is the most common complication after cataract surgery.

BACKGROUND:

We aimed to assess the relationship between intraocular lens (IOL) diopter and formation of PCO among a consecutive real-world registry.

DESIGN:

Cohort study.

PARTICIPANTS:

Included were 14 264 consecutive cases of uncomplicated cataract surgery performed during 2014 to 2018 in Helsinki University Hospital in Finland.

METHODS:

NdYAG capsulotomies were used as an estimate of clinically significant PCO. A single eye of each patient and a single type of IOL were included. MAIN OUTCOME

MEASURE:

NdYAG posterior capsulotomy free survival.

RESULTS:

Mean age was 73.2 ± 9.9 years and 61.8% were female. Mean follow-up time was 25.4 ± 16.8 months. Overall PCO rates were 1.1% at 1-year, 3.0% at 2-year, 7.1% at 3-year and 10.2% at 4-year. Patients with IOL diopters (D) in the lower quartile (≤20.0 D) had significantly higher rates of PCO (1.3% at 1-year, 4.4% at 2-years, 9.4% at 3-years and 14.2% at 4-years, P < .001). A logistic regression model showed increased risk for PCO formation with lower diopter IOLs; for ≤20.0 D OR 1.343 (95% CI 1.132-1.593), for ≤10.0 D OR 2.409 (95% CI 1.203-4.287), P < .001 for all comparisons. In a multivariant regression accounting for possible confounders, results remained consistent. CONCLUSIONS AND RELEVANCE Among a cohort of patients undergoing cataract surgery, use of lower diopter IOLs was associated with increased incidence of clinically significant PCO. Research into IOL biomechanics to decrease PCO may be warranted especially in lower diopter IOLs.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Catarata / Facoemulsificação / Lasers de Estado Sólido / Opacificação da Cápsula / Lentes Intraoculares Tipo de estudo: Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Female / Humans Idioma: En Revista: Clin Exp Ophthalmol Assunto da revista: OFTALMOLOGIA Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Finlândia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Catarata / Facoemulsificação / Lasers de Estado Sólido / Opacificação da Cápsula / Lentes Intraoculares Tipo de estudo: Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Female / Humans Idioma: En Revista: Clin Exp Ophthalmol Assunto da revista: OFTALMOLOGIA Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Finlândia