Combination of Deep Learning-Based Denoising and Iterative Reconstruction for Ultra-Low-Dose CT of the Chest: Image Quality and Lung-RADS Evaluation.
Hata, Akinori; Yanagawa, Masahiro; Yoshida, Yuriko; Miyata, Tomo; Tsubamoto, Mitsuko; Honda, Osamu; Tomiyama, Noriyuki.
Afiliação
  • Hata A; Department of Future Diagnostic Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka 565-0871, Japan.
  • Yanagawa M; Department of Diagnostic and Interventional Radiology, Osaka University Graduate School of Medicine, Osaka, Japan.
  • Yoshida Y; Department of Diagnostic and Interventional Radiology, Osaka University Graduate School of Medicine, Osaka, Japan.
  • Miyata T; Department of Diagnostic and Interventional Radiology, Osaka University Graduate School of Medicine, Osaka, Japan.
  • Tsubamoto M; Department of Future Diagnostic Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka 565-0871, Japan.
  • Honda O; Department of Radiology, Kansai Medical University, Osaka, Japan.
  • Tomiyama N; Department of Diagnostic and Interventional Radiology, Osaka University Graduate School of Medicine, Osaka, Japan.
AJR Am J Roentgenol ; 215(6): 1321-1328, 2020 12.
Article em En | MEDLINE | ID: mdl-33052702
ABSTRACT
OBJECTIVE. The objective of our study was to assess the effect of the combination of deep learning-based denoising (DLD) and iterative reconstruction (IR) on image quality and Lung Imaging Reporting and Data System (Lung-RADS) evaluation on chest ultra-low-dose CT (ULDCT). MATERIALS AND METHODS. Forty-one patients with 252 nodules were evaluated retrospectively. All patients underwent ULDCT (mean ± SD, 0.19 ± 0.01 mSv) and standard-dose CT (SDCT) (6.46 ± 2.28 mSv). ULDCT images were reconstructed using hybrid iterative reconstruction (HIR) and model-based iterative reconstruction (MBIR), and they were postprocessed using DLD (i.e., HIR-DLD and MBIR-DLD). SDCT images were reconstructed using filtered back projection. Three independent radiologists subjectively evaluated HIR, HIR-DLD, MBIR, and MBIR-DLD images on a 5-point scale in terms of noise, streak artifact, nodule edge, clarity of small vessels, homogeneity of the normal lung parenchyma, and overall image quality. Two radiologists independently evaluated the nodules according to Lung-RADS using HIR, MBIR, HIR-DLD, and MBIR-DLD ULDCT images and SDCT images. The median scores for subjective analysis were analyzed using Wilcoxon signed rank test with Bonferroni correction. Intraobserver agreement for Lung-RADS category between ULDCT and SDCT was evaluated using the weighted kappa coefficient. RESULTS. In the subjective analysis, ULDCT with DLD showed significantly better scores than did ULDCT without DLD (p < 0.001), and MBIR-DLD showed the best scores among the ULDCT images (p < 0.001) for all items. In the Lung-RADS evaluation, HIR showed fair or moderate agreement (reader 1 and reader 2 κw = 0.46 and 0.32, respectively); MBIR, moderate or good agreement (κw = 0.68 and 0.57); HIR-DLD, moderate agreement (κw = 0.53 and 0.48); and MBIR-DLD, good agreement (κw = 0.70 and 0.72). CONCLUSION. DLD improved the image quality of both HIR and MBIR on ULDCT. MBIR-DLD was superior to HIR_DLD for image quality and for Lung-RADS evaluation.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tomografia Computadorizada por Raios X / Aprendizado Profundo / Neoplasias Pulmonares Tipo de estudo: Observational_studies / Prognostic_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: AJR Am J Roentgenol Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tomografia Computadorizada por Raios X / Aprendizado Profundo / Neoplasias Pulmonares Tipo de estudo: Observational_studies / Prognostic_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: AJR Am J Roentgenol Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Japão