Your browser doesn't support javascript.
loading
Detecting the abuse of 19-norsteroids in doping controls: A new gas chromatography coupled to isotope ratio mass spectrometry method for the analysis of 19-norandrosterone and 19-noretiocholanolone.
Iannella, Loredana; Colamonici, Cristiana; Curcio, Davide; Botrè, Francesco; de la Torre, Xavier.
Afiliação
  • Iannella L; Laboratorio Antidoping, Federazione Medico Sportiva Italiana, Rome, Italy.
  • Colamonici C; Dipartimento di Chimica e Tecnologia del Farmaco, "Sapienza" Università di Roma, Rome, Italy.
  • Curcio D; Laboratorio Antidoping, Federazione Medico Sportiva Italiana, Rome, Italy.
  • Botrè F; Laboratorio Antidoping, Federazione Medico Sportiva Italiana, Rome, Italy.
  • de la Torre X; Laboratorio Antidoping, Federazione Medico Sportiva Italiana, Rome, Italy.
Drug Test Anal ; 13(4): 770-784, 2021 Apr.
Article em En | MEDLINE | ID: mdl-33242373
ABSTRACT
The detection of 19-norsteroids abuse in doping controls currently relies on the determination of 19-norandrosterone (19-NA) by gas chromatography-tandem mass spectrometry (GC-MS/MS). An additional confirmatory analysis by gas chromatography coupled to isotope ratio mass spectrometry (GC-C-IRMS) is performed on samples showing 19-NA concentrations between 2.5 and 15 ng/ml and not originated from pregnant female athletes or female treated with 19-norethisterone. 19-Noretiocholanolone (19-NE) is typically produced to a lesser extent as a secondary metabolite. The aim of this work was to improve the GC-C-IRMS confirmation procedure for the detection of 19-norsteroids misuse. Both 19-NA and 19-NE were analyzed as target compounds (TCs), whereas androsterone (A), pregnanediol (PD), and pregnanetriol (PT) were selected as endogenous reference compounds (ERCs). The method was validated and applied to urine samples collected by three male volunteers after the administration of nandrolone-based formulations. Before the instrumental analysis, urine samples (<25 ml) were hydrolyzed with ß-glucuronidase from Escherichia coli and extracted with n-pentane. Compounds of interest were purified through a single (for PT) or double (for 19-NE, 19-NA, A, and PD) liquid chromatographic step, to reduce the background noise and eliminate interferences that could have affect the accuracy of δ13 C values. The limit of quantification (LOQ) of 2 ng/ml was ensured for both 19-NA and 19-NE. The 19-NE determination could be helpful in case of "unstable" urine samples, in late excretion phases or when coadministration with 5α-reductase inhibitors occur.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Detecção do Abuso de Substâncias / Dopagem Esportivo / Estranos / Cromatografia Gasosa-Espectrometria de Massas Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Drug Test Anal Assunto da revista: FARMACOLOGIA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Itália

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Detecção do Abuso de Substâncias / Dopagem Esportivo / Estranos / Cromatografia Gasosa-Espectrometria de Massas Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Drug Test Anal Assunto da revista: FARMACOLOGIA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Itália