Your browser doesn't support javascript.
loading
Accuracy of saliva and nasopharyngeal sampling for detection of SARS-CoV-2 in community screening: a multicentric cohort study.
Kernéis, Solen; Elie, Caroline; Fourgeaud, Jacques; Choupeaux, Laure; Delarue, Séverine Mercier; Alby, Marie-Laure; Quentin, Pierre; Pavie, Juliette; Brazille, Patricia; Néré, Marie Laure; Minier, Marine; Gabassi, Audrey; Gibaud, Aurélien; Gauthier, Sébastien; Leroy, Chrystel; Voirin-Mathieu, Etienne; Poyart, Claire; Vidaud, Michel; Parfait, Béatrice; Delaugerre, Constance; Tréluyer, Jean-Marc; LeGoff, Jérôme.
Afiliação
  • Kernéis S; Université de Paris, INSERM, IAME, 75018, Paris, France. solen.kerneis@aphp.fr.
  • Elie C; Equipe de Prévention du Risque Infectieux, AP-HP, Hôpital Bichat, 46 rue Henri Huchard, 75018, Paris, France. solen.kerneis@aphp.fr.
  • Fourgeaud J; Institut Pasteur, Epidemiology and Modelling of Antibiotic Evasion, 75015, Paris, France. solen.kerneis@aphp.fr.
  • Choupeaux L; Clinical Research Unit / Clinical Investigation Center, APHP, Necker-Enfants Malades Hospital, 75015, Paris, France.
  • Delarue SM; EA 7323 Pharmacologie Et Thérapeutique de L'enfant Et de La Femme Enceinte, Université de Paris, 75015, Paris, France.
  • Alby ML; Virologie, AP-HP, Hôpital Necker-Enfants Malades, 75015, Paris, France.
  • Quentin P; Equipe Hospitalo-Universitaire 7328, Prise en Charge Des Anomalies Congénitales Et de Leur Traitement, Institut Imagine, Université de Paris, 75015, Paris, France.
  • Pavie J; Clinical Research Unit / Clinical Investigation Center, APHP, Necker-Enfants Malades Hospital, 75015, Paris, France.
  • Brazille P; Virologie, AP-HP, Hôpital Saint Louis, 75010, Paris, France.
  • Néré ML; Centre de Dépistage COVISAN 13 14 15, Communauté Professionnelle de Territoire de Santé, 75014, Paris, France.
  • Minier M; Centre de Dépistage COVISAN 13 14 15, Communauté Professionnelle de Territoire de Santé, 75014, Paris, France.
  • Gabassi A; Immuno-Infectiologie, AP-HP, Hôtel Dieu, 75004, Paris, France.
  • Gibaud A; Centre de Dépistage COVISAN, AP-HP, Hôtel Dieu, 75004, Paris, France.
  • Gauthier S; Centre de Dépistage COVISAN, AP-HP, Hôtel Dieu, 75004, Paris, France.
  • Leroy C; Espace Santé Jeunes - Unité Guy Môquet, AP-HP, Hôtel Dieu, 75004, Paris, France.
  • Voirin-Mathieu E; Virologie, AP-HP, Hôpital Saint Louis, 75010, Paris, France.
  • Poyart C; Virologie, AP-HP, Hôpital Saint Louis, 75010, Paris, France.
  • Vidaud M; Virologie, AP-HP, Hôpital Saint Louis, 75010, Paris, France.
  • Parfait B; Virologie, AP-HP, Hôpital Saint Louis, 75010, Paris, France.
  • Delaugerre C; Centre de Ressources Biologiques - Site Cochin, AP-HP, Fédération des CRB/PRB D'AP-HP. Centre-Université de Paris, Hôpital Cochin, 75014, Paris, France.
  • Tréluyer JM; Plateforme SeqOIA, AP-HP, 75014, Paris, France.
  • LeGoff J; Plateforme SeqOIA, AP-HP, 75014, Paris, France.
Eur J Clin Microbiol Infect Dis ; 40(11): 2379-2388, 2021 Nov.
Article em En | MEDLINE | ID: mdl-34342768
Nasopharyngeal sampling for nucleic acid amplification testing (NAAT) is the standard diagnostic test of coronavirus disease 2019. Our objectives were to assess, in real-life conditions, the diagnostic accuracy of a nasopharyngeal point-of-care antigen (Ag) test and of saliva NAAT for detection of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) in ambulatory care. This was a prospective cohort study from 19 October through 18 December 2020 in two community COVID-19 screening centers in Paris, France. Two nasopharyngeal swabs and one saliva sample were simultaneously collected. Diagnostic accuracies of nasopharyngeal Ag testing and of three saliva NAAT methods were assessed as compared to nasopharyngeal NAAT. A total of 1452 ambulatory children and adults were included. Overall, 129/1443 (9%) participants tested positive on nasopharyngeal NAAT (102/564 [18%] in symptomatic and 27/879 [3%] in asymptomatic participants). Sensitivity was 94%, 23%, 96%, and 94% for the three different protocols of saliva NAAT and for the nasopharyngeal Ag test, respectively. Estimates of specificity were above 95% for all methods. Diagnostic accuracy was similar in symptomatic and asymptomatic individuals. Diagnostic accuracy of nasopharyngeal Ag testing and of saliva NAAT is similar to that of nasopharyngeal NAAT, subject to compliance with specific protocols for saliva. Registration number: NCT04578509.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Saliva / Manejo de Espécimes / Nasofaringe / Teste para COVID-19 / SARS-CoV-2 / COVID-19 Tipo de estudo: Clinical_trials / Diagnostic_studies / Etiology_studies / Guideline / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies / Screening_studies Limite: Adult / Female / Humans / Male / Middle aged País/Região como assunto: Europa Idioma: En Revista: Eur J Clin Microbiol Infect Dis Assunto da revista: DOENCAS TRANSMISSIVEIS / MICROBIOLOGIA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: França

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Saliva / Manejo de Espécimes / Nasofaringe / Teste para COVID-19 / SARS-CoV-2 / COVID-19 Tipo de estudo: Clinical_trials / Diagnostic_studies / Etiology_studies / Guideline / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies / Screening_studies Limite: Adult / Female / Humans / Male / Middle aged País/Região como assunto: Europa Idioma: En Revista: Eur J Clin Microbiol Infect Dis Assunto da revista: DOENCAS TRANSMISSIVEIS / MICROBIOLOGIA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: França