Your browser doesn't support javascript.
loading
Improving Consistency of Photobiomodulation Therapy: A Novel Flat-Top Beam Hand-Piece versus Standard Gaussian Probes on Mitochondrial Activity.
Amaroli, Andrea; Arany, Praveen; Pasquale, Claudio; Benedicenti, Stefano; Bosco, Alessandro; Ravera, Silvia.
Afiliação
  • Amaroli A; Department of Orthopedic Dentistry, Faculty of Dentistry, First Moscow State Medical University (Sechenov University), 119991 Moscow, Russia.
  • Arany P; Department of Surgical and Diagnostic Sciences, University of Genoa, 16132 Genoa, Italy.
  • Pasquale C; Departments of Oral Biology, Surgery and Biomedical Engineering, University at Buffalo, Buffalo, NY 14260, USA.
  • Benedicenti S; Department of Surgical and Diagnostic Sciences, University of Genoa, 16132 Genoa, Italy.
  • Bosco A; Department of Surgical and Diagnostic Sciences, University of Genoa, 16132 Genoa, Italy.
  • Ravera S; Bosco Ottica S.r.l., Castel Rozzone, 24040 Bergamo, Italy.
Int J Mol Sci ; 22(15)2021 Jul 21.
Article em En | MEDLINE | ID: mdl-34360559
The tremendous therapeutic potential of photobiomodulation therapy in different branches of medicine has been described in the literature. One of the molecular mechanisms for this treatment implicates the mitochondrial enzyme, cytochrome C oxidase. However, the efficacy and consistency of clinical outcomes with photobiomodulation treatments has been fiercely debated. This work was motivated by this need to improve photobiomodulation devices and delivery approaches. We designed a novel hand-piece with a flat-top beam profile of irradiation. We compared the beam profile versus a standard hand-piece and a fibre probe. We utilized isolated mitochondria and performed treatments at various spots within the beam, namely, the centre, left and right edge. We examined mitochondrial activity by assessing ATP synthesis with the luciferin/luciferase chemiluminescent method as a primary endpoint, while mitochondrial damage was assessed as the secondary endpoint. We observed a uniform distribution of the power density with the flat-top prototype compared to a wide Gaussian beam profile with the standard fibre and standard hand-piece. We noted increased production of ATP in the centre of all three beams with respect to the non-treated controls (p < 0.05). Both the fibre and standard hand-piece demonstrated less increase in ATP synthesis at the edges than the centre (p < 0.05). In contrast, ATP synthesis was increased homogenously in the flat-top handpiece, both in the centre and the edges of the beam. Fibre, standard hand-piece and the flat-top hand-piece prototype have discrete beam distribution characteristics. This significantly affected the mitochondrial activity with respect to their position within the treated areas. Flat-top hand-piece enhances the uniformity of photobiomodulation treatments and can improve the rigour and reproducibility of PBM clinical outcomes.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Consumo de Oxigênio / Trifosfato de Adenosina / Complexo IV da Cadeia de Transporte de Elétrons / Lasers Semicondutores / Mitocôndrias Limite: Humans Idioma: En Revista: Int J Mol Sci Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Federação Russa

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Consumo de Oxigênio / Trifosfato de Adenosina / Complexo IV da Cadeia de Transporte de Elétrons / Lasers Semicondutores / Mitocôndrias Limite: Humans Idioma: En Revista: Int J Mol Sci Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Federação Russa