Your browser doesn't support javascript.
loading
Bayesian inference of multi-point macromolecular architecture mixtures at nanometre resolution.
Embacher, Peter A; Germanova, Tsvetelina E; Roscioli, Emanuele; McAinsh, Andrew D; Burroughs, Nigel J.
Afiliação
  • Embacher PA; Department of Medical Physics & Biomedical Engineering, University College London, London, United Kingdom.
  • Germanova TE; Centre for Mechanochemical Cell Biology and Division of Biomedical Sciences, Warwick Medical School, University of Warwick, Coventry, United Kingdom.
  • Roscioli E; Centre for Mechanochemical Cell Biology and Division of Biomedical Sciences, Warwick Medical School, University of Warwick, Coventry, United Kingdom.
  • McAinsh AD; Centre for Mechanochemical Cell Biology and Division of Biomedical Sciences, Warwick Medical School, University of Warwick, Coventry, United Kingdom.
  • Burroughs NJ; Mathematics Institute and Zeeman Institute, University of Warwick, Coventry, United Kingdom.
PLoS Comput Biol ; 18(12): e1010765, 2022 12.
Article em En | MEDLINE | ID: mdl-36574448
Gaussian spot fitting methods have significantly extended the spatial range where fluorescent microscopy can be used, with recent techniques approaching nanometre (nm) resolutions. However, small inter-fluorophore distances are systematically over-estimated for typical molecular scales. This bias can be corrected computationally, but current algorithms are limited to correcting distances between pairs of fluorophores. Here we present a flexible Bayesian computational approach that infers the distances and angles between multiple fluorophores and has several advantages over these previous methods. Specifically it improves confidence intervals for small lengths, estimates measurement errors of each fluorophore individually and infers the correlations between polygon lengths. The latter is essential for determining the full multi-fluorophore 3D architecture. We further developed the algorithm to infer the mixture composition of a heterogeneous population of multiple polygon states. We use our algorithm to analyse the 3D architecture of the human kinetochore, a macro-molecular complex that is essential for high fidelity chromosome segregation during cell division. Using triple fluorophore image data we unravel the mixture of kinetochore states during human mitosis, inferring the conformation of microtubule attached and unattached kinetochores and their proportions across mitosis. We demonstrate that the attachment conformation correlates with intersister tension and sister alignment to the metaphase plate.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cinetocoros / Microtúbulos Limite: Humans Idioma: En Revista: PLoS Comput Biol Assunto da revista: BIOLOGIA / INFORMATICA MEDICA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cinetocoros / Microtúbulos Limite: Humans Idioma: En Revista: PLoS Comput Biol Assunto da revista: BIOLOGIA / INFORMATICA MEDICA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Reino Unido