Your browser doesn't support javascript.
loading
Utility of serum ketone levels for assessment of myocardial glucose suppression for 18F-fluorodeoxyglucose PET in patients referred for evaluation of endocarditis.
Madamanchi, Chaitanya; Weinberg, Richard L; Murthy, Venkatesh L.
Afiliação
  • Madamanchi C; Frankel Cardiovascular Center, Division of Cardiovascular Medicine, Department of Internal Medicine, University of Michigan, Ann Arbor, MI, USA. cmadaman@med.umich.edu.
  • Weinberg RL; Division of Cardiology, Feinberg School of Medicine, Northwestern University, Chicago, IL, USA.
  • Murthy VL; Frankel Cardiovascular Center, Division of Cardiovascular Medicine, Department of Internal Medicine, University of Michigan, Ann Arbor, MI, USA.
J Nucl Cardiol ; 30(3): 928-937, 2023 06.
Article em En | MEDLINE | ID: mdl-36823484
BACKGROUND: 18F-FDG PET/CT is used to diagnose cardiac sarcoidosis and endocarditis. It requires myocardial glucose utilization (MGU) suppression to avoid false positives, which occur in up to 20% of patients. Serum beta-hydroxybutyrate (BHB) levels may help identify incomplete suppression of MGU. We determined the optimal timing and diagnostic thresholds to identify incomplete suppression of MGU. METHODS AND RESULTS: We retrospectively identified 114 patients referred for 18F-FDG PET/CT for endocarditis, wherein myocardial uptake outside of paravalvular regions is not related to pathology and can be confidently ascribed as being due to inadequate suppression of MGU. Patients followed a high-fat, low-carbohydrate diet and received heparin. Serum BHB, insulin, glucose and hemoglobin A1c were measured. Maximum standardized uptake value (SUVmax) of left ventricle (LV) and mean SUV (SUVmean) in LV blood pool (LVBP) was measured. Logistic regression and area under the receiver-operating characteristic analyses were used to quantify the relationship between biomarkers and MGU suppression. A threshold of BHB ≥ 0.35 mmol·L-1 to detect suppression resulted in sensitivity of 88% and specificity of 61%. A threshold of BHB ≥ 0.95 mmol·L-1 resulted in sensitivity of 45% and specificity of 100%. AUC was 0.87. BHB measured ~ 4 hours prior to 18F-FDG injection performed similarly to or better than later timepoints. CONCLUSIONS: Serum BHB levels are useful for assessing suppression of MGU and could simplify interpretation of 18F-FDG PET/CT inflammation studies.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fluordesoxiglucose F18 / Endocardite Tipo de estudo: Observational_studies / Prognostic_studies Limite: Humans Idioma: En Revista: J Nucl Cardiol Assunto da revista: CARDIOLOGIA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fluordesoxiglucose F18 / Endocardite Tipo de estudo: Observational_studies / Prognostic_studies Limite: Humans Idioma: En Revista: J Nucl Cardiol Assunto da revista: CARDIOLOGIA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Estados Unidos