Rate-Adaptive Atrial Pacing for Heart Failure With Preserved Ejection Fraction: The RAPID-HF Randomized Clinical Trial.
JAMA
; 329(10): 801-809, 2023 03 14.
Article
em En
| MEDLINE
| ID: mdl-36871285
Importance: Reduced heart rate during exercise is common and associated with impaired aerobic capacity in heart failure with preserved ejection fraction (HFpEF), but it remains unknown if restoring exertional heart rate through atrial pacing would be beneficial. Objective: To determine if implanting and programming a pacemaker for rate-adaptive atrial pacing would improve exercise performance in patients with HFpEF and chronotropic incompetence. Design, Setting, and Participants: Single-center, double-blind, randomized, crossover trial testing the effects of rate-adaptive atrial pacing in patients with symptomatic HFpEF and chronotropic incompetence at a tertiary referral center (Mayo Clinic) in Rochester, Minnesota. Patients were recruited between 2014 and 2022 with 16-week follow-up (last date of follow-up, May 9, 2022). Cardiac output during exercise was measured by the acetylene rebreathe technique. Interventions: A total of 32 patients were recruited; of these, 29 underwent pacemaker implantation and were randomized to atrial rate responsive pacing or no pacing first for 4 weeks, followed by a 4-week washout period and then crossover for an additional 4 weeks. Main Outcomes and Measures: The primary end point was oxygen consumption (VÌo2) at anaerobic threshold (VÌo2,AT); secondary end points were peak VÌo2, ventilatory efficiency (VÌe/VÌco2 slope), patient-reported health status by the Kansas City Cardiomyopathy Questionnaire Overall Summary Score (KCCQ-OSS), and N-terminal pro-brain natriuretic peptide (NT-proBNP) levels. Results: Of the 29 patients randomized, the mean age was 66 years (SD, 9.7) and 13 (45%) were women. In the absence of pacing, peak VÌo2 and VÌo2 at anaerobic threshold (VÌo2,AT) were both correlated with peak exercise heart rate (r = 0.46-0.51, P < .02 for both). Pacing increased heart rate during low-level and peak exercise (16/min [95% CI, 10 to 23], P < .001; 14/min [95% CI, 7 to 21], P < .001), but there was no significant change in VÌo2,AT (pacing off, 10.4 [SD, 2.9] mL/kg/min; pacing on, 10.7 [SD, 2.6] mL/kg/min; absolute difference, 0.3 [95% CI, -0.5 to 1.0] mL/kg/min; P = .46), peak VÌo2, minute ventilation (VÌe)/carbon dioxide production (VÌco2) slope, KCCQ-OSS, or NT-proBNP level. Despite the increase in heart rate, atrial pacing had no significant effect on cardiac output with exercise, owing to a decrease in stroke volume (-24 mL [95% CI, -43 to -5 mL]; P = .02). Adverse events judged to be related to the pacemaker device were observed in 6 of 29 participants (21%). Conclusions and Relevance: In patients with HFpEF and chronotropic incompetence, implantation of a pacemaker to enhance exercise heart rate did not result in an improvement in exercise capacity and was associated with increased adverse events. Trial Registration: ClinicalTrials.gov Identifier: NCT02145351.
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Fibrilação Atrial
/
Insuficiência Cardíaca
Tipo de estudo:
Clinical_trials
/
Prognostic_studies
Limite:
Aged
/
Female
/
Humans
/
Male
Idioma:
En
Revista:
JAMA
Ano de publicação:
2023
Tipo de documento:
Article