Comparison of post contrast fluid attenuated inversion recovery, 3D T1-SPACE, and T1W MRI sequences with fat suppression in the diagnosis of infectious meningitis.
Mishra, Satyakam; Naik, Suprava; Bhoi, Sanjeev Kumar; Kumar, Mukesh; Deep Bag, Nerbadyswari; Dey, Anupam; Mohakud, Sudipta; Mahapatro, Samarendra.
Afiliação
  • Mishra S; Department of Radiodiagnosis, All India Institute of Medical Sciences, India.
  • Naik S; Department of Radiodiagnosis, All India Institute of Medical Sciences, India.
  • Bhoi SK; Department of Neurology, All India Institute of Medical Sciences, India.
  • Kumar M; Department of Neurology, All India Institute of Medical Sciences, India.
  • Deep Bag N; Department of Radiodiagnosis, All India Institute of Medical Sciences, India.
  • Dey A; Department of General Medicine, All India Institute of Medical Sciences, India.
  • Mohakud S; Department of Radiodiagnosis, All India Institute of Medical Sciences, India.
  • Mahapatro S; Department of Paediatrics, All India Institute of Medical Sciences, India.
Neuroradiol J ; 36(5): 572-580, 2023 Oct.
Article em En | MEDLINE | ID: mdl-36908255
ABSTRACT

OBJECTIVE:

To assess the usefulness of post contrast Fluid attenuated inversion recovery (FLAIR), 3D T1-SPACE, and T1W magnetic resonance imaging (MRI) sequences with fat suppression in diagnosis of infectious meningitis.

METHODS:

75 patients with clinical suspicion of meningitis were evaluated with post contrast FLAIR (PC-FLAIR), post contrast T1-SPACE (PC-T1-SPACE), and post contrast T1WI (PC-T1WI). Sensitivity, specificity, positive predictive value, and negative predictive value of individual sequences were assessed.

RESULTS:

The sensitivity of PC-FLAIR (88.4%) was greater than PC-T1-SPACE (85.5%) and PC-T1WI (82.6%), considering cerebrospinal fluid (CSF) analysis as gold standard (p < 0.05). Kappa inter-rater agreement between two radiologists was 0.921 for PC-T1-SPACE, 0.921 for PC-T1WI, and 1.0 for PC-FLAIR with a p value <0.05. Both PC-T1-SPACE and PC-FLAIR performed equally in sulcal space enhancement. PC-T1-SPACE and PC-T1WI performed better in evaluation of pachymeningeal enhancement, ependymal enhancement in cases of ventriculitis, whereas PC-FLAIR was more sensitive in assessment of basal cistern enhancement and enhancement along the cerebellar folia.

CONCLUSION:

Meningeal enhancement could be better appreciated in PC-FLAIR image than PC-T1WI and PC-T1-SPACE. Enhancement in PC-T1-SPACE was comparable to that of PC-T1WI. Being a T1 based spin echo sequence, PC-T1-SPACE has all the advantages of PC-T1WI in addition to its ability to differentiate meningeal enhancement from leptomeningeal vessels. Hence, PC-T1WI can be replaced by PC-T1-SPACE and PC-FLAIR can be added to routine MRI protocol in suspected case of meningitis.