Temperature-Tuning Desorption Ionization for Ambient Mass Spectrometry.
Li, Ningxi; Cai, Zhijun; Zhang, Zhongyao; Zhang, Wenpeng; Ma, Xiaoxiao; Zhou, Xiaoyu; Ouyang, Zheng.
Afiliação
  • Li N; State Key Laboratory of Precision Measurement Technology and Instruments, Department of Precision Instrument, Tsinghua University, Beijing 100084, China.
  • Cai Z; State Key Laboratory of Precision Measurement Technology and Instruments, Department of Precision Instrument, Tsinghua University, Beijing 100084, China.
  • Zhang Z; State Key Laboratory of Precision Measurement Technology and Instruments, Department of Precision Instrument, Tsinghua University, Beijing 100084, China.
  • Zhang W; State Key Laboratory of Precision Measurement Technology and Instruments, Department of Precision Instrument, Tsinghua University, Beijing 100084, China.
  • Ma X; State Key Laboratory of Precision Measurement Technology and Instruments, Department of Precision Instrument, Tsinghua University, Beijing 100084, China.
  • Zhou X; State Key Laboratory of Precision Measurement Technology and Instruments, Department of Precision Instrument, Tsinghua University, Beijing 100084, China.
  • Ouyang Z; State Key Laboratory of Precision Measurement Technology and Instruments, Department of Precision Instrument, Tsinghua University, Beijing 100084, China.
Anal Chem ; 95(29): 11099-11105, 2023 Jul 25.
Article em En | MEDLINE | ID: mdl-37431610
ABSTRACT
In the past decade, mass spectrometry (MS) has been widely used for a broad range of on-site applications. This is largely attributed to the rapid advancement of technologies, such as ambient ionization and mass spectrometer miniaturization. Here, we report the development of the temperature-tuning desorption ionization (TTDI) method for versatile on-site applications using a miniature MS system. A unique feature of TTDI is its dynamic temperature range applicable from 30 to 800 °C, which enables optimal desorption ionization applied for chemical and biological compounds through tuning the temperature at the sampling spot. The versatility of TTDI has been demonstrated through on-site MS analysis of a variety of samples, such as explosives on surfaces, drugs of abuse in biofluids, and screening biomarkers in tissues.