Your browser doesn't support javascript.
loading
Evaluating femoral graft placement using three-dimensional magnetic resonance imaging in the reconstruction of the anterior cruciate ligament via independent or transtibial drilling techniques: a retrospective cohort study.
Legler, Jack; Laverdiere, Carl; Boily, Mathieu; Tarchala, Magdalena; Hart, Adam; Martineau, Paul A.
Afiliação
  • Legler J; Faculty of Medicine and Health Sciences, McGill University, Montreal, Canada. jack.legler@mail.mcgill.ca.
  • Laverdiere C; Department of Orthopedic Surgery, McGill University Health Centre, Montreal, Canada.
  • Boily M; Department of Diagnostic Radiology, McGill University Health Centre, Montreal, Canada.
  • Tarchala M; Department of Orthopedic Surgery, Fraser Health, Vancouver, Canada.
  • Hart A; Department of Orthopedic Surgery, McGill University Health Centre, Montreal, Canada.
  • Martineau PA; Department of Orthopedic Surgery, McGill University Health Centre, Montreal, Canada.
Eur J Orthop Surg Traumatol ; 34(3): 1297-1306, 2024 Apr.
Article em En | MEDLINE | ID: mdl-38078954
ABSTRACT

PURPOSE:

Anterior cruciate ligament (ACL) reconstruction is a common surgical procedure, yet failure still largely occurs due to nonanatomically positioned grafts. The purpose of this study was to retrospectively evaluate patients with torn ACLs before and after reconstruction via 3D MRI and thereby assess the accuracy of graft position on the femoral condyle.

METHODS:

Forty-one patients with unilateral ACL tears were recruited. Each patient underwent 3D MRI of both knees before and after surgery. The location of the reconstructed femoral footprint relative to the patient's native footprint was compared.

RESULTS:

Native ACL anatomical location of the native ACL had a significant impact on graft position. Native ACLs that were previously more anterior yielded grafts that were more posterior (3.70 ± 1.22 mm, P = 0.00018), and native ACL that were previously more proximal yielded grafts that were more distal (3.25 ± 1.09 mm, P = 0.0042). Surgeons using an independent drilling method positioned 76.2% posteriorly relative to the native location, with a mean 0.1 ± 2.8 mm proximal (P = 0.8362) and 1.8 ± 3.0 mm posterior (P = 0.0165). Surgeons using a transtibial method positioned 75% proximal relative to the native location, with a mean 2.2 ± 3.0 mm proximal (P = 0.0042) and 0.2 ± 2.6 mm posterior (P = 0.8007). These two techniques showed a significant difference in magnitude in the distal-proximal axis (P = 0.0332).

CONCLUSION:

The femoral footprint position differed between the native and reconstructed ACLs, suggesting that ACL reconstructions are not accurate. Rather, they are converging to a normative reference point that is neither anatomical nor isometric.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ligamento Cruzado Anterior / Lesões do Ligamento Cruzado Anterior Limite: Humans Idioma: En Revista: Eur J Orthop Surg Traumatol Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Canadá

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ligamento Cruzado Anterior / Lesões do Ligamento Cruzado Anterior Limite: Humans Idioma: En Revista: Eur J Orthop Surg Traumatol Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Canadá