Enhancing electrospray ionization efficiency for particle transmission through an aerodynamic lens stack.
Rafie-Zinedine, Safi; Varma Yenupuri, Tej; Worbs, Lena; Maia, Filipe R N C; Heymann, Michael; Schulz, Joachim; Bielecki, Johan.
Afiliação
  • Rafie-Zinedine S; European XFEL, Holzkoppel 4, 22869 Schenefeld, Germany.
  • Varma Yenupuri T; Laboratory of Molecular Biophysics, Department of Cell and Molecular Biology, Uppsala University, Husargatan 3 (Box 596), 75124 Uppsala, Sweden.
  • Worbs L; Laboratory of Molecular Biophysics, Department of Cell and Molecular Biology, Uppsala University, Husargatan 3 (Box 596), 75124 Uppsala, Sweden.
  • Maia FRNC; Laboratory of Molecular Biophysics, Department of Cell and Molecular Biology, Uppsala University, Husargatan 3 (Box 596), 75124 Uppsala, Sweden.
  • Heymann M; Institute of Biomaterials and Biomolecular Systems, University of Stuttgart, Pfaffenwaldring 57, 70569 Stuttgart, Germany.
  • Schulz J; European XFEL, Holzkoppel 4, 22869 Schenefeld, Germany.
  • Bielecki J; European XFEL, Holzkoppel 4, 22869 Schenefeld, Germany.
J Synchrotron Radiat ; 31(Pt 2): 222-232, 2024 Mar 01.
Article em En | MEDLINE | ID: mdl-38306300
ABSTRACT
This work investigates the performance of the electrospray aerosol generator at the European X-ray Free Electron Laser (EuXFEL). This generator is, together with an aerodynamic lens stack that transports the particles into the X-ray interaction vacuum chamber, the method of choice to deliver particles for single-particle coherent diffractive imaging (SPI) experiments at the EuXFEL. For these experiments to be successful, it is necessary to achieve high transmission of particles from solution into the vacuum interaction region. Particle transmission is highly dependent on efficient neutralization of the charged aerosol generated by the electrospray mechanism as well as the geometry in the vicinity of the Taylor cone. We report absolute particle transmission values for different neutralizers and geometries while keeping the conditions suitable for SPI experiments. Our findings reveal that a vacuum ultraviolet ionizer demonstrates a transmission efficiency approximately seven times greater than the soft X-ray ionizer used previously. Combined with an optimized orifice size on the counter electrode, we achieve >40% particle transmission from solution into the X-ray interaction region. These findings offer valuable insights for optimizing electrospray aerosol generator configurations and data rates for SPI experiments.