Your browser doesn't support javascript.
loading
Test characteristics of point-of-care ultrasonography in patients with acute kidney injury.
Gaudreau-Simard, Mathilde; Saiyin, Tana; Mcinnes, Matthew D F; Ruller, Sydney; Clark, Edward G; Wooller, Krista; Kilabuk, Elaine; Forster, Alan J; Woo, Michael Y.
Afiliação
  • Gaudreau-Simard M; Division of General Internal Medicine, The Ottawa Hospital-General Campus, 501 Smyth Road, Ottawa, ON, K1H 8L6, Canada. magaudreau@toh.ca.
  • Saiyin T; Ottawa Hospital Research Institute, Ottawa, ON, Canada. magaudreau@toh.ca.
  • Mcinnes MDF; Department of Medicine, University of Ottawa, Ottawa, ON, Canada. magaudreau@toh.ca.
  • Ruller S; Department of Medicine, University of Ottawa, Ottawa, ON, Canada.
  • Clark EG; Ottawa Hospital Research Institute, Ottawa, ON, Canada.
  • Wooller K; Department of Diagnostic Imaging, University of Ottawa, Ottawa, ON, Canada.
  • Kilabuk E; Ottawa Hospital Research Institute, Ottawa, ON, Canada.
  • Forster AJ; Ottawa Hospital Research Institute, Ottawa, ON, Canada.
  • Woo MY; Department of Medicine, University of Ottawa, Ottawa, ON, Canada.
Ultrasound J ; 16(1): 15, 2024 Feb 22.
Article em En | MEDLINE | ID: mdl-38388747
ABSTRACT

BACKGROUND:

Acute kidney injury is a common disorder that is associated with significant morbidity and mortality. Point-of-care ultrasonography (PoCUS) is an imaging modality performed at the bedside and is used to assess for obstructive causes of acute kidney injury. Little is known about the test characteristics of PoCUS in patients with acute kidney injury.

OBJECTIVE:

Our primary objective was to describe the test characteristics of PoCUS for the detection of hydronephrosis in patients presenting with acute kidney injury at our centre. Our secondary objective was to describe the current rate of use of PoCUS for this indication.

RESULTS:

In total, 7873 patients were identified between June 1, 2019 and April 30, 2021, with 4611 meeting inclusion criteria. Of these, 94 patients (2%) underwent PoCUS, and 65 patients underwent both PoCUS and reference standard, for a total of 124 kidneys included in our diagnostic accuracy analysis. The prevalence of hydronephrosis in our cohort was 33% (95% CI 25-41%). PoCUS had a sensitivity of 85% (95% CI 71-94%) and specificity of 78% (95% CI 68-87%) for the detection of hydronephrosis.

CONCLUSION:

We describe the test characteristics of PoCUS for the detection of hydronephrosis in a cohort of patients with acute kidney injury. The low uptake of this test presents an opportunity for quality improvement work to increase its use for this indication.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Ultrasound J Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Canadá

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Ultrasound J Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Canadá