Your browser doesn't support javascript.
loading
Critical Review of Selected Analytical Platforms for GC-MS Metabolomics Profiling-Case Study: HS-SPME/GC-MS Analysis of Blackberry's Aroma.
Ljujic, Jovana; Vujisic, Ljubodrag; Tesevic, Vele; Sofrenic, Ivana; Ivanovic, Stefan; Simic, Katarina; Andelkovic, Boban.
Afiliação
  • Ljujic J; Faculty of Chemistry, University of Belgrade, Studentski trg 12-16, 11000 Belgrade, Serbia.
  • Vujisic L; Faculty of Chemistry, University of Belgrade, Studentski trg 12-16, 11000 Belgrade, Serbia.
  • Tesevic V; Faculty of Chemistry, University of Belgrade, Studentski trg 12-16, 11000 Belgrade, Serbia.
  • Sofrenic I; Faculty of Chemistry, University of Belgrade, Studentski trg 12-16, 11000 Belgrade, Serbia.
  • Ivanovic S; Institute of Chemistry, Technology and Metallurgy, National Institute of the Republic of Serbia, University of Belgrade, Njegoseva 12, 11000 Belgrade, Serbia.
  • Simic K; Institute of Chemistry, Technology and Metallurgy, National Institute of the Republic of Serbia, University of Belgrade, Njegoseva 12, 11000 Belgrade, Serbia.
  • Andelkovic B; Faculty of Chemistry, University of Belgrade, Studentski trg 12-16, 11000 Belgrade, Serbia.
Foods ; 13(8)2024 Apr 17.
Article em En | MEDLINE | ID: mdl-38672895
ABSTRACT
Data processing and data extraction are the first, and most often crucial, steps in metabolomics and multivariate data analysis in general. There are several software solutions for these purposes in GC-MS metabolomics. It becomes unclear which platform offers what kind of data and how that information influences the analysis's conclusions. In this study, selected analytical platforms for GC-MS metabolomics profiling, SpectConnect and XCMS as well as MestReNova software, were used to process the results of the HS-SPME/GC-MS aroma analyses of several blackberry varieties. In addition, a detailed analysis of the identification of the individual components of the blackberry aroma club varieties was performed. In total, 72 components were detected in the XCMS platform, 119 in SpectConnect, and 87 and 167 in MestReNova, with automatic integral and manual correction, respectively, as well as 219 aroma components after manual analysis of GC-MS chromatograms. The obtained datasets were fed, for multivariate data analysis, to SIMCA software, and underwent the creation of PCA, OPLS, and OPLS-DA models. The results of the validation tests and VIP-pred. scores were analyzed in detail.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Foods Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Foods Ano de publicação: 2024 Tipo de documento: Article