Determination of Azole Fungicide Residues in Fresh Juice by Magnetic Solid Phase Extraction Based on Fe3O4@ZnAl-LDH@MIL-53(Al) Sorbent in Combination with High-Performance Liquid Chromatograph.
Yang, Shu-Tong; Cao, Yi-Wen; Zeng, Zi-Ying; Gang, Zheng; Chen, Min; Du, Bing-Yan; Su, Miao-Miao; Yang, Zhong-Hua; Tang, Zhu-Hua; Zeng, Yun-Liu.
Afiliação
  • Yang ST; College of Plant Science and Technology, Department of Plant Protection, Huazhong Agricultural University, Wuhan 430070, China.
  • Cao YW; College of Plant Science and Technology, Department of Plant Protection, Huazhong Agricultural University, Wuhan 430070, China.
  • Zeng ZY; College of Plant Science and Technology, Department of Plant Protection, Huazhong Agricultural University, Wuhan 430070, China.
  • Gang Z; College of Plant Science and Technology, Department of Plant Protection, Huazhong Agricultural University, Wuhan 430070, China.
  • Chen M; College of Plant Science and Technology, Department of Plant Protection, Huazhong Agricultural University, Wuhan 430070, China.
  • Du BY; College of Plant Science and Technology, Department of Plant Protection, Huazhong Agricultural University, Wuhan 430070, China.
  • Su MM; College of Plant Science and Technology, Department of Plant Protection, Huazhong Agricultural University, Wuhan 430070, China.
  • Yang ZH; College of Plant Science and Technology, Department of Plant Protection, Huazhong Agricultural University, Wuhan 430070, China.
  • Tang ZH; Hainan Institute for Food Control, Key Laboratory of Tropical Fruits and Vegetables Quality and Safety for State Market Regulation, Haikou 570314, China.
  • Zeng YL; National Key Laboratory for Germplasm Innovation & Utilization of Horticultural Crops, Wuhan 430070, China.
J Chromatogr Sci ; 2024 May 17.
Article em En | MEDLINE | ID: mdl-38757928
ABSTRACT
In this work, a magnetic adsorption material based on metal-organic framework (Fe3O4@ZnAl-LDH@MIL-53(Al)) was synthesized and used as an adsorbent in the process of magnetic solid phase extraction. Then, a high-performance liquid chromatograph was used to quantitatively detect triazole fungicides in samples. In order to verify the successful preparation of the material, a series of characterization analyses were carried out. Besides, the key parameters that may affect the extraction efficiency have been optimized, and under optimal conditions the three triazole fungicides showed good linearity in the range of 10-1000 µg/L (R2 ≥ 0.9796); Limit of detections were ranged from 0.013 to 0.030 µg/mL. Finally, the established method was applied to the detection of triazole fungicides in four fresh juice samples. The results showed that the target analyte was not detected in all the test samples. By detecting the recoveries (73.3-104.3%) and coefficient variation (RSD ≤ 6.8%) of triazole fungicides in fortified samples, it proved that this established method meets the requirements of pesticide residue analysis and showed excellent application potential.