Your browser doesn't support javascript.
loading
[Determination of six bisphenols in human urine by ultra-high performance liquid chromatography-tandem mass spectrometry].
Pei, Ziwei; Zhuo, Qin; Zhang, Lei; Li, Jingguang; Zhao, Yunfeng.
Afiliação
  • Pei Z; NHC Key Laboratory of Public Nutrition and Health, National Institute for Nutrition and Health, Chinese Center for Disease Control and Prevention, Beijing 100050, China.
  • Zhuo Q; NHC Key Laboratory of Public Nutrition and Health, National Institute for Nutrition and Health, Chinese Center for Disease Control and Prevention, Beijing 100050, China.
  • Zhang L; China National Center for Food Safety Risk Assessment, Chinese Academy of Medical Sciences Research Unit ( No.2019RU014), Beijing 100021, China.
  • Li J; China National Center for Food Safety Risk Assessment, Chinese Academy of Medical Sciences Research Unit ( No.2019RU014), Beijing 100021, China.
  • Zhao Y; China National Center for Food Safety Risk Assessment, Chinese Academy of Medical Sciences Research Unit ( No.2019RU014), Beijing 100021, China.
Wei Sheng Yan Jiu ; 53(3): 447-454, 2024 May.
Article em Zh | MEDLINE | ID: mdl-38839587
ABSTRACT

OBJECTIVE:

To develop and validate a solid phase extraction-ultra-high performance liquid chromatography-tandem mass spectrometry method for the determination of six bisphenols(bisphenol S, bisphenol F, bisphenol A, 2, 2'-methylenediphenol, bisphenol AF, bisphenol AP) in urine.

METHODS:

After enzymolysis of urine sample, the target substances were quickly purified and extracted by WAX solid phase extraction column. On ACQUITY BEH C_(18) column(2.1 mm×100 mm, 1.7 µm), the mobile phase of water and methanol was used to separate. Finally, multi-reaction detection was carried out under electrospray negative ion scanning, and quantification was carried out by internal standard method.

RESULTS:

The correlation coefficients(r) of the target compounds were all more than 0.998 in the range of 0.1-50.0 ng/mL, the linearity was good, and the detection limits were all lower than 0.1 ng/mL. The recoveries of the three standard concentrations(0.5, 5.0 and 50.0 ng/mL) were all between 80% and 120%, and the relative standard deviation was less than 20%(n=5). The standard reference material was detected and the concentration was within the reference range.

CONCLUSION:

This method can be used to detect six bisphenols in urine quickly and accurately, is suitable for the trace analysis of bisphenol compounds in human urine.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fenóis / Compostos Benzidrílicos / Espectrometria de Massas em Tandem Limite: Humans Idioma: Zh Revista: Wei Sheng Yan Jiu Assunto da revista: SAUDE PUBLICA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fenóis / Compostos Benzidrílicos / Espectrometria de Massas em Tandem Limite: Humans Idioma: Zh Revista: Wei Sheng Yan Jiu Assunto da revista: SAUDE PUBLICA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China