Your browser doesn't support javascript.
loading
[A colloidal gold immunochromatography-based method for detecting enramycin residues in feed].
Wang, Kang; Yu, Pu; Chen, Kong; Chen, Min; Cai, Yonghui; Wang, Bingqing.
Afiliação
  • Wang K; School of Food Science and Biotechnology, Zhejiang Gongshang University, Hangzhou 310018, Zhejiang, China.
  • Yu P; School of Food Science and Biotechnology, Zhejiang Gongshang University, Hangzhou 310018, Zhejiang, China.
  • Chen K; School of Food Science and Biotechnology, Zhejiang Gongshang University, Hangzhou 310018, Zhejiang, China.
  • Chen M; School of Food Science and Biotechnology, Zhejiang Gongshang University, Hangzhou 310018, Zhejiang, China.
  • Cai Y; School of Food Science and Biotechnology, Zhejiang Gongshang University, Hangzhou 310018, Zhejiang, China.
  • Wang B; School of Food Science and Biotechnology, Zhejiang Gongshang University, Hangzhou 310018, Zhejiang, China.
Sheng Wu Gong Cheng Xue Bao ; 40(7): 2346-2356, 2024 Jul 25.
Article em Zh | MEDLINE | ID: mdl-39044596
ABSTRACT
To achieve rapid detection of enramycin in feed, we employed the competitive inhibition method to develop a colloidal gold immunochromatographic test strip based on the anti-enramycin A monoclonal antibody (anti-Er.A-mAb). Colloidal gold probes were prepared with a laboratory-prepared high-purity anti-Er.A-mAb. The effects of pH, antibody titer, and antigen concentration (test line) on the test strip performance were investigated. The colloidal gold test strip prepared with 8 µL potassium carbonate addition, 4 µg/mL antibody, 1.0 mg/mL antigen (test line), and 3 µL gold-labeled antibody showed acceptable specificity and a low limit of detection. The test strip showed the detection limit of 25 ng/mL for enramycin A, with a linear range of 25-300 ng/mL. The experiments on the feed with positive sample addition proved that the test strip had good repeatability and was more sensitive than high-performance liquid chromatography, being applicable for the rapid detection of enramycin in large batches of feed samples.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cromatografia de Afinidade / Coloide de Ouro / Ração Animal / Anticorpos Monoclonais Idioma: Zh Revista: Sheng Wu Gong Cheng Xue Bao Assunto da revista: BIOTECNOLOGIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cromatografia de Afinidade / Coloide de Ouro / Ração Animal / Anticorpos Monoclonais Idioma: Zh Revista: Sheng Wu Gong Cheng Xue Bao Assunto da revista: BIOTECNOLOGIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China