1.
BJU Int ; 125(1): 8-16, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31373142

RESUMO

OBJECTIVES: To summarize the current evidence on Retzius-sparing (RS)-robot-assisted radical prostatectomy (RARP) and to compare its oncological, peri-operative and functional outcomes with those of standard retropubic RARP (S-RARP). MATERIALS AND METHODS: After establishing an a priori protocol, a systematic electronic literature search was conducted in January 2019 using the Medline (via PubMed), Embase (via Ovid) and Cochrane databases. The search strategy relied on the 'PICO' (Patient Intervention Comparison Outcome) criteria and article selection was carried out in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Only studies reporting the oncological and functional outcomes of RARP (as determined by type of procedure [RS-RARP vs S-RARP]) were considered for inclusion. Risk of bias and study quality were assessed. Finally, peri-operative and functional outcomes were recorded and analysed. RESULTS: A shorter operating time was associated with RS-RARP (weighted mean difference [WMD] 14.7 min, 95% confidence interval [CI] -28.25, 1.16; P = 0.03), whereas no significant difference was found in terms of estimated blood loss (WMD 1.45 mL, 95% CI -31.18, 34.08; P = 0.93). Also, no significant difference between the two groups was observed for overall (odds ratio [OR] 0.86, 95% CI 0.40, 1.85; P = 0.71) and major (Clavien >3; OR 0.88, 95% CI 0.30, 2.57) postoperative complications; however, the likelihood of positive surgical margins (PSMs) was lower for the S-RARP group (rate 15.2% vs 24%; OR 1.71, 95% CI 1.12, 2.60; P = 0.01). The cumulative analysis showed a statistically significant advantage for RS-RARP in terms of continence recovery at 1 month (OR 2.54, 95% CI 1.16, 5.53; P = 0.02), as well as at 3 months (OR 3.86, 95% CI 2.23, 6.68; P < 0.001), 6 months (OR 3.61, 95% CI 1.88, 6.91; P = 0.001), and 12 months (OR 7.29, 95% CI 1.89, 28.13; P = 0.004). CONCLUSION: Our analysis confirms that RS-RARP is a safe and feasible alternative to S-RARP. This novel approach may be associated with faster and higher recovery of continence, without increasing the risk of complications. One caveat might be the higher risk of PSMs, and this can be regarded as a current pitfall of the technique, probably related to an expected learning curve.


Assuntos
Tratamentos com Preservação do Órgão , Prostatectomia/métodos , Procedimentos Cirúrgicos Robóticos , Humanos , Masculino , Procedimentos Cirúrgicos Robóticos/métodos , Resultado do Tratamento
2.
Urol Int ; 100(2): 134-138, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29346781

RESUMO

Background/Aims/Objectives: Various nephron-sparing approaches were described as part of surgical management for Fraley's syndrome, a rare anatomic variant of the renal vascular anatomy that compresses the upper pole infundibulum resulting in an upper calyceal obstruction and dilatation, with symptoms of flank pain and hematuria. To date, descriptions of minimally invasive correction techniques are anecdotal. METHODS: A retroperitoneal pure laparoscopic approach using the nephron-sparing technique was chosen in the presented case. RESULTS: In this report, we demonstrated that if laparoscopic calycectomy is performed without clamping of renal branches, parenchymal ischemia can be completely avoided. Additionally, the preservation of renal tissue surrounding the calyx enables the preservation of the intrasinusal segmental arteries flow, thereby avoiding their accidental closure by hemostatic sutures. CONCLUSIONS: In conclusion, Laparoscopic Nephron-Sparing Calycectomy is a safe and effective surgical procedure for the treatment of Fraley's syndrome. Consistent laparoscopic experience is required before embarking on this kind of surgery.


Assuntos
Cálices Renais/cirurgia , Rim/irrigação sanguínea , Laparoscopia , Obstrução da Artéria Renal/cirurgia , Procedimentos Cirúrgicos Urológicos/métodos , Malformações Vasculares/cirurgia , Feminino , Dor no Flanco/etiologia , Hematúria/etiologia , Humanos , Laparoscopia/efeitos adversos , Pessoa de Meia-Idade , Obstrução da Artéria Renal/etiologia , Síndrome , Resultado do Tratamento , Procedimentos Cirúrgicos Urológicos/efeitos adversos , Malformações Vasculares/complicações
3.
Eur Urol ; 85(4): 348-360, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38044179

RESUMO

BACKGROUND: Multiple and heterogeneous techniques have been described for orthotopic neobladder (ONB) reconstruction after robot-assisted radical cystectomy. Nonetheless, a systematic assessment of all the available options is lacking. OBJECTIVE: To provide the first comprehensive step-by-step description of all the available techniques for robotic intracorporeal ONB together with individual intraoperative, perioperative and functional outcomes based on a systematic review of the literature. DESIGN, SETTING, AND PARTICIPANTS: We performed a systematic review of the literature, and MEDLINE/PubMed, Embase, Scopus, and Web of Science databases were searched to identify original articles describing different robotic intracorporeal ONB techniques and reporting intra- and perioperative outcomes. Studies were categorized according to ONB type, providing a synthesis of the current evidence. Video material was provided by experts in the field to illustrate the surgical technique of each intracorporeal ONB. SURGICAL PROCEDURE: Nine different ONB types were identified: Studer, Hautmann, Y shape, U shape, Bordeaux, Pyramid, Shell, Florence Robotic Intracorporeal Neobladder, and Padua Ileal Neobladder. MEASUREMENTS: Continuous and categorical variables are presented as mean ± standard deviation and as frequencies and proportions, respectively. RESULTS AND LIMITATIONS: Of 2587 studies identified, 19 met our inclusion criteria. No cohort studies or randomized control trials comparing different neobladder types are available. Available techniques for intracorporeal robotic ONB reconstruction have similar operative time, estimated blood loss, intraoperative complications, and length of stay. Major variability exists concerning postoperative complications and functional outcomes, likely related to reporting bias. CONCLUSIONS: Several techniques are described for intracorporeal ONB during robot-assisted radical cystectomy with comparable perioperative outcomes. We provide the first step-by-step surgical atlas for robot-assisted ONB reconstruction. Further comparative studies are needed to assess any advantage of one technique over others. PATIENT SUMMARY: Patients elected for radical cystectomy should be aware that multiple techniques for robotic orthotopic neobladder are available, but that current evidence does not favor one type over the others.


Assuntos
Procedimentos Cirúrgicos Robóticos , Robótica , Neoplasias da Bexiga Urinária , Derivação Urinária , Humanos , Cistectomia/efeitos adversos , Cistectomia/métodos , Derivação Urinária/efeitos adversos , Derivação Urinária/métodos , Procedimentos Cirúrgicos Robóticos/efeitos adversos , Procedimentos Cirúrgicos Robóticos/métodos , Neoplasias da Bexiga Urinária/cirurgia , Resultado do Tratamento
4.
Minerva Urol Nephrol ; 75(6): 761-765, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-38126287

RESUMO

The aim of this study is to present the first Italian experience with robotic-assisted retrograde intrarenal surgery (rRIRS) using the Ily® platform. Procedures were performed for renal stones using the Ily® Robot (STERLAB, Vallauris, France), which is a ureteroscope holder with multiple degrees of freedom that can be controlled remotely through a wireless controller. In March 2023, consecutive patients with indications for rRIRS were included in the study. Demographic variables and stone characteristics were collected, and standard perioperative data were assessed. The one-month stone-free rate (SFR, i.e. no residual fragments) was evaluated using ultrasound. All participating surgeons filled out a Surgeons' Satisfaction Questionnaire (SSQ) based on a Likert-type scale. The questionnaire focused on: 1) ease of use; 2) ergonomics during renal cavity exploration; 3) stability during stone fragmentation. Among the patients, one had bilateral stones, while two had stones on the right side. The mean stone size was 13 mm. The average operative time was 70 minutes and the mean docking time was three minutes. No perioperative complications were recorded, and all patients were discharged on the first postoperative day. The one-month SFR was 100%. The SSQ scores were as follows: 1) ease of use: 4/5; 2) ergonomics: 5/5; 3) stability during stone fragmentation: 5/5. Based on the initial experience, the results indicate the feasibility, safety, and effectiveness of rRIRS. The ergonomic efficiency of the system was highly appreciated by the surgeons. While a cost-effectiveness analysis within clinical trials is necessary, rRIRS shows the potential for a more sustainable future for endoscopists and an improved workplace environment.


Assuntos
Cálculos Renais , Robótica , Humanos , Ureteroscopia/efeitos adversos , Resultado do Tratamento , Cálculos Renais/diagnóstico por imagem , Cálculos Renais/cirurgia , Ureteroscópios
5.
Minerva Urol Nephrol ; 75(2): 223-230, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36847584

RESUMO

BACKGROUND: Patients with multiple ipsilateral renal masses have an augmented risk of metachronous contralateral lesions and are likely to undergo repeated surgeries. We report our experience with the technologies currently available and the surgical techniques to preserve healthy parenchyma while guaranteeing oncological radicality during robot-assisted partial nephrectomy (RAPN). METHODS: The data were collected at three tertiary-care centers, where 61 patients with multiple ipsilateral renal masses were treated with RAPN between 2012 and 2021. RAPN was performed with da Vinci Si or Xi surgical system using TilePro (Life360; San Francisco, CA, USA), indocyanine green fluorescence and intraoperative ultrasound. Three-dimensional reconstructions were built in some cases preoperatively. Different techniques were employed for hilum management. The primary endpoint is to report intra- and postoperative complications. Secondary endpoints were the estimated blood loss (EBL), warm ischemia time (WIT) and positive surgical margins (PSM) rate. RESULTS: Median preoperative size of the largest mass was 37.5 mm (24-51) with a median PADUA and R.E.N.A.L. score of 8 (7-9) and 7 (6-9). One hundred forty-two tumors were excised, with a mean number of 2.32. The median WIT was 17 (12-24) minutes, and the median EBL was 200 (100-400) mL. Intraoperative ultrasound was employed in 40 (67.8%) patients. The rate of early unclamping, selective clamping and zero-ischemia were respectively 13 (21.3%), 6 (9.8%) and 13 (21.3%). ICG fluorescence was employed in 21 (34.42%) patients and three-dimensional reconstructions were built in 7 (11.47%) patients. Three (4.8%) intraoperative complications occurred, all classified as grade-1 according to EAUiaiC. Postoperative complications were reported in 14 (22.9%) cases with 2 Clavien-Dindo grade >2 complications. Four (6.56%) patients had PSM. Mean period of follow-up was 21 months. CONCLUSIONS: In experienced hands, with the employment of the currently available technologies and surgical techniques, RAPN can guarantee optimal outcomes in patients with multiple ipsilateral renal masses.


Assuntos
Neoplasias Renais , Robótica , Humanos , Robótica/métodos , Neoplasias Renais/diagnóstico por imagem , Neoplasias Renais/cirurgia , Neoplasias Renais/patologia , Resultado do Tratamento , Nefrectomia/métodos , Complicações Pós-Operatórias/etiologia
6.
J Ultrasound ; 25(2): 225-232, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34031862

RESUMO

PURPOSE: To assess the use of the new Focal-One® HIFU platform in salvage setting to evaluate the occurrence of postoperative complications. METHODS: Patients who underwent salvage HIFU (sHIFU) with Focal-One® platform were enrolled prospectively (Candiolo cancer institute-FPO IRCCS; registry number: 258/2018). Perioperative and postoperative outcomes (in terms of oncological and functional ones) were recorded during the first year of follow-up. In particular postoperative complications were classified according to Clavien-Dindo system. RESULTS: 20 patients were enrolled. No grade 3 complications were recorded. Referring to grade 2 complications, eight patients reported urgency after 3 months of follow-up, and in 4 cases, a low urinary tract infection occurred. Evaluating the impact of sHIFU on patients' sexual potency, micturition and quality of life, no significant deterioration was recorded during the follow-up as proven using the ANOVA analysis for repeated measurements. Only two patient had a biochemical failure after 12 months of follow-up. CONCLUSIONS: The real-time intraoperative guidance with Focal-One® platform, allows a continuous monitoring and tailoring of the treatment, with a minimization of the adverse events even in a salvage setting.


Assuntos
Ablação por Ultrassom Focalizado de Alta Intensidade , Qualidade de Vida , Humanos , Recidiva Local de Neoplasia , Complicações Pós-Operatórias/terapia , Terapia de Salvação/efeitos adversos , Resultado do Tratamento
7.
Minerva Urol Nephrol ; 73(2): 165-177, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33200906

RESUMO

INTRODUCTION: Urinary incontinence is one of the most scared sequelae of robot assisted radical prostatectomy (RARP). Therefore, different surgical modifications, aimed to restore the original anatomy, were proposed to overcome this issue. The purpose of this study is to assess which is the best reconstruction technique (posterior only: PR; anterior only: AR; total: TR) compared to the standard approach for continence recovery after RARP in a tertiary care center. EVIDENCE ACQUISITION: After establishing an a priori protocol, a systematic electronic literature search was conducted in May 2019. The article selection proceeded in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) guidelines and was registered (PROSPERO registry number 131667). The risk of bias and the quality assessment of the included studies were performed. Simple pooled analysis was performed for continence rates according to the definition of continence (0 pad vs. 0-1 pad) and the different types of reconstruction at 1, 4, 12, 24, 52 weeks after RARP. Complication rate, operative and console time and estimated blood loss were pooled. Two-side test of proportion and T-test were used to compare rates and mean, respectively. EVIDENCE SYNTHESIS: Six studies meeting the inclusion criteria were found and included in the analysis. All the included studies were of "poor" or "good" quality. A high or moderate risk of bias was recorded. TR showed higher continence recovery rates, compared to their anterior reconstruction counterpart at 1, 4, 12, 24, 52 weeks (P<0.001 at all time-points). At 12 weeks TR showed the highest continence rates (P<0.001), followed by AR and PR. No statistically significant differences were recorded regarding anastomosis-related complication rates (anastomosis stricture P=0.08; urine leakage P=0.1). CONCLUSIONS: In patients undergoing RARP, TR facilitates a faster and higher continence recovery compared to standard approach or PR or AR only.


Assuntos
Procedimentos de Cirurgia Plástica/métodos , Complicações Pós-Operatórias/prevenção & controle , Prostatectomia/métodos , Neoplasias da Próstata/cirurgia , Procedimentos Cirúrgicos Robóticos , Incontinência Urinária/prevenção & controle , Humanos , Masculino , Recuperação de Função Fisiológica , Resultado do Tratamento , Incontinência Urinária/etiologia
8.
Eur Urol ; 78(3): 301-303, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32334884

RESUMO

The speed and reach of the COVID-19 pandemic have forced rapid changes in how we conduct medical practice and research. The rapid evolution in how scientific meetings are conducted may have long-term benefits. A new reality in which technology and sociality are merged may offer a more engaging and adaptable scientific congress experience with more flexible and dynamic use of content modulated to the needs of each attendee.


Assuntos
Controle de Doenças Transmissíveis , Congressos como Assunto , Infecções por Coronavirus , Pandemias , Pneumonia Viral , Telecomunicações , Betacoronavirus , COVID-19 , Congressos como Assunto/organização & administração , Congressos como Assunto/tendências , Infecções por Coronavirus/epidemiologia , Infecções por Coronavirus/prevenção & controle , Transmissão de Doença Infecciosa/prevenção & controle , Previsões , Humanos , Invenções , Pandemias/prevenção & controle , Pneumonia Viral/epidemiologia , Pneumonia Viral/prevenção & controle , SARS-CoV-2 , Telecomunicações/organização & administração , Telecomunicações/tendências
9.
Urol Oncol ; 38(4): 286-292, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31956077

RESUMO

OBJECTIVES: Surgically treated clinical T1 (cT1) kidney cancer has in general a good prognosis, but there is a risk of upstaging that can potentially jeopardize the oncological outcomes after partial nephrectomy (PN). Aim of this study is to analyze the outcomes of robot-assisted PN (RAPN) for cT1 kidney cancer upstaged to pT3a, and to identify predictors of upstaging. MATERIAL AND METHODS: The study cohort included 1,640 cT1 patients who underwent RAPN between 2005 and 2018 at 10 academic institutions. Multivariate logistic regression model was used to assess the predictors of upstaging. Kaplan-Meier curves and multivariable Cox regression analyses were used to evaluate recurrence-free survival and overall survival. RESULTS: Overall, 74 (4%) were upstaged cases (cT1/pT3a). Upstaged patients presented larger renal tumors (3.1 vs. 2.4 cm; P = 0.001), and higher R.E.N.A.L. score (8.0 vs. 6.0; P = 0.004). cT1/pT3a group had higher rate of intraoperative complications (5 vs. 1% P = 0.032), higher pathological tumor size (3.2 vs. 2.5 cm; P < 0.001), higher rate of Fuhrman grade ≥3 (32 vs. 17%; P = 0.002), and higher number of sarcomatoid differentiation (4 vs. 1%; P = 0.008). Chronic kidney disease (CKD) stage ≥3 (OR: 2.54; P < 0.014), and clinical tumor size (OR: 1.07; P < 0.001) were independent predictors of upstaging. cT1/pT3a group had worse 2-year (94% vs. 99%) recurrence-free survival (P < 0.001). CONCLUSIONS: Upstaging to pT3a in patients with cT1 renal mass undergoing RAPN represents an uncommon event, involving less than 5% of cases. Pathologic upstaging might translate into worse oncological outcomes, and therefore strict follow-up protocols should be applied in these cases.


Assuntos
Neoplasias Renais/cirurgia , Nefrectomia/métodos , Procedimentos Cirúrgicos Robóticos/métodos , Robótica/métodos , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
10.
Minerva Chir ; 74(1): 63-77, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30037176

RESUMO

Urinary incontinence after radical prostatectomy (RP) is still an issue and may compromise patient quality of life and psychosocial behavior, regardless of oncologic outcomes. As this condition usually resolves by the end of the first postoperative year, many surgeons focused their attention on "early" return of urinary continence (UC). The aim of this non-systematic review is to present an overview of the current knowledge on the anatomy and the surgical techniques addressed to early functional recovery of continence after RP. The available literature data suggest that the preservation of bladder neck, pubo-prostatic ligaments, endopelvic fascia and vesico-urethral complex may play a role in recovery of early UC. Similarly, bladder neck reconstruction, anterior and/or posterior myo-fascio-ligamentous support to the anastomosis and tension-free watertight vesico-urethral anastomosis can improve early UC recovery post RP. More recently surgical approaches (i.e. Retzius-sparing technique) seem to add a piece in the jigsaw in the scenario of the early recovery of UC. Notwithstanding the efforts of the surgeons, more evidence from randomized studies is required to prove benefits of the different approaches and the "ideal" RP is far to be standardized.


Assuntos
Prostatectomia/métodos , Neoplasias da Próstata/cirurgia , Recuperação de Função Fisiológica , Micção/fisiologia , Humanos , Masculino , Complicações Pós-Operatórias/prevenção & controle , Próstata/anatomia & histologia , Próstata/cirurgia , Fatores de Tempo , Incontinência Urinária/prevenção & controle
11.
Minerva Urol Nefrol ; 69(6): 604-612, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28429925

RESUMO

BACKGROUND: New approaches have been developed to further reduce the invasiveness of laparoscopic pyeloplasty (P) as treatment for uretero-pelvic junction obstruction (UPJO). Aim of the study was to compare perioperative, functional and cosmetic results of mini-laparoscopic (mL-P) versus robot-assisted laparoendoscopic single-site P (rLESS-P). METHODS: Since April 2009 to June 2010, 12 adult patients with primary UPJO, BMI<25 and no previous abdominal surgeries were enrolled undergoing mLP (3-mm instruments only). With the same indications since February 2012 to October 2013, 15 patients underwent rLESS-P with "single site"® platform (Intuitive Surgery Inc, Sunnyvale, CA, USA). Success of surgeries was determined by clinical parameters and renal scan (success if T 1/2<20 min) at 12 months postoperatively. Demographics and perioperative results were analyzed. Cosmetic results were assessed by using the Patient Scar Assessment Questionnaire (PSAQ). RESULTS: Groups were comparable at baseline. No differences were found in perioperative variables except for a longer operative time in rLESS-P group (128 vs. 190, P<0.001). Postoperative complications rate, analgesic consumption, pain visual analogue scale scores, hospital stay and success rate of surgeries were not significantly different between the groups. PSAQ revealed that in both the groups patients were satisfied with the cosmetic result. At one-year follow-up no recurrences were observed. Semiquantitative analysis of costs revealed an extra-cost for rLESS-P of € 3410 per procedure. CONCLUSIONS: In our experience, both mLP and rLESS-P appeared to be feasible and safe in the treatment of UPJO and allowed for excellent cosmetic results. r-LESS required longer operative times and higher costs.


Assuntos
Cicatriz/prevenção & controle , Endoscopia/métodos , Laparoscopia/métodos , Procedimentos Cirúrgicos Robóticos/métodos , Obstrução Ureteral/cirurgia , Adulto , Idoso , Cicatriz/epidemiologia , Endoscopia/economia , Feminino , Humanos , Laparoscopia/economia , Masculino , Pessoa de Meia-Idade , Assistência Perioperatória , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/prevenção & controle , Resultado do Tratamento , Obstrução Ureteral/economia , Procedimentos Cirúrgicos Urológicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA