1.
J Med Internet Res ; 23(5): e26349, 2021 05 27.
Artigo em Inglês | MEDLINE | ID: mdl-34042589

RESUMO

BACKGROUND: Connected devices are dramatically changing many aspects in health care. One such device, the virtual reality (VR) headset, has recently been shown to improve analgesia in a small sample of patients undergoing transcatheter aortic valve implantation. OBJECTIVE: We aimed to investigate the feasibility and effectiveness of VR in patients undergoing atrial fibrillation (AF) ablation under conscious sedation. METHODS: All patients who underwent an AF ablation with VR from March to May 2020 were included. Patients were compared to a consecutive cohort of patients who underwent AF ablation in the 3 months prior to the study. Primary efficacy was assessed by using a visual analog scale, summarizing the overall pain experienced during the ablation. RESULTS: The AF cryoablation procedure with VR was performed for 48 patients (mean age 63.0, SD 10.9 years; n=16, 33.3% females). No patient refused to use the device, although 14.6% (n=7) terminated the VR session prematurely. Preparation of the VR headset took on average 78 (SD 13) seconds. Compared to the control group, the mean perceived pain, assessed with the visual analog scale, was lower in the VR group (3.5 [SD 1.5] vs 4.3 [SD 1.6]; P=.004), and comfort was higher in the VR group (7.5 [SD 1.6] vs 6.8 [SD 1.7]; P=.03). On the other hand, morphine consumption was not different between the groups. Lastly, complications, as well as procedure and fluoroscopy duration, were not different between the two groups. CONCLUSIONS: We found that VR was associated with a reduction in the perception of pain in patients undergoing AF ablation under conscious sedation. Our findings demonstrate that VR can be easily incorporated into the standard ablation workflow.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Realidade Virtual , Fibrilação Atrial/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Dor , Manejo da Dor , Resultado do Tratamento
3.
Heart ; 99(18): 1336-41, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23624488

RESUMO

OBJECTIVE: We analysed long-term results of percutaneous mitral commissurotomy (PMC) performed because of mitral restenosis after previous commissurotomy. DESIGN: Follow-up of a prospective cohort. SETTING: Tertiary university hospital. PATIENTS: We studied 163 consecutive patients who underwent PMC because of restenosis occurring 16 ± 8 years after previous commissurotomy (closed-heart in 121, open-heart in 30 and PMC in 12). Mean age was 48 ± 14 years; 62 patients (38%) had valve calcification. Restenosis was due to bicommissural fusion in all cases. INTERVENTION: PMC using a single or double balloon in 80 patients and the Inoue balloon in 83. RESULTS: Good immediate results (IR) (valve area ≥ 1.5 cm2 with MR ≤ 2/4) were obtained in 135 pts (83%). 20-year rates were 27.9 ± 4.7% for cardiovascular survival without mitral surgery and 14.8 ± 3.9% for good functional results (cardiovascular survival without reintervention on the mitral valve and in New York Heart Association (NYHA) class I or II). After good IR, 20-year rates were 33.2 ± 5.5% for cardiovascular survival without surgery and 17.9 ± 4.7% for good functional results. After good IR, multivariate predictive factors of poor late functional results were higher NYHA class (p = 0.01), atrial fibrillation (p = 0.0002) and higher mean mitral gradient after PMC (p = 0.004). CONCLUSIONS: In patients with restenosis after mitral commissurotomy, PMC provides good IR in most cases. After good IR, one patient out of three remains free from surgery and one out of five has good functional results at 20 years. These findings support the use of PMC after previous commissurotomy, particularly in selected patients with few symptoms and in sinus rhythm.


Assuntos
Estenose da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Intervenção Coronária Percutânea , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estenose da Valva Mitral/mortalidade , Reoperação , Resultado do Tratamento , Adulto Jovem
4.
Circ., cariovasc. interv. (Print) ; 11(11): 006927, Nov. 2018. tab, graf
Artigo em Inglês | Sec. Est. Saúde SP, CONASS, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1223598

RESUMO

BACKGROUND: The impact of preexisting left bundle branch block (LBBB) in transcatheter aortic valve replacement (TAVR) recipients is unknown. The aim of this study was to determine the impact of preexisting LBBB on clinical outcomes after TAVR. METHODS AND RESULTS: This multicenter study evaluated 3404 TAVR candidates according to the presence or absence of LBBB on baseline ECG. TAVR complications and causes of death were defined according to Valve Academic Research Consortium-2 definitions. Follow-up outpatient visits or telephone interviews were conducted at 30 days, 12 months, and yearly thereafter. Echocardiography examinations were performed at baseline, at hospital discharge, and at 1-year follow-up. Preexisting LBBB was present in 398 patients (11.7%) and was associated with an increased risk of permanent pacemaker implantation (PPI; 21.1% versus 14.8%; adjusted odds ratio, 1.51; 95% CI, 1.12­2.04) but not death (7.3% versus 5.5%; adjusted odds ratio, 1.33; 95% CI, 0.84­2.12) at 30 days. At a mean follow-up of 22±21 months, there were no differences between patients with and without preexisting LBBB in overall mortality (adjusted hazard ratio, 0.94; 95% CI, 0.75­1.18) and cardiovascular mortality (adjusted hazard ratio, 0.90; 95% CI, 0.68­1.21). In a subanalysis of 2421 patients without PPI at 30 days and with complete follow-up about the PPI, preexisting LBBB was not associated with an increased risk of PPI or sudden cardiac death. Patients with preexisting LBBB had a lower left ventricular ejection fraction (LVEF) at baseline and at 1-year follow-up (P <0.001 for both), but those with low LVEF exhibited a similar increase in LVEF over time after TAVR compared with patients with no preexisting LBBB (P=0.327). CONCLUSIONS: Preexisting LBBB significantly increased the risk of early (but not late) PPI after TAVR, without any significant effect on overall mortality or cardiovascular mortality. Preexisting LBBB was associated with lower LVEF pre-TAVR but did not prevent an increase in LVEF post-TAVR similar to patients without LBBB.


Assuntos
Bloqueio de Ramo , Substituição da Valva Aórtica Transcateter/estatística & dados numéricos
5.
JACC cardiovasc. interv ; 10(15): 1564-1574, 2017. tab, graf
Artigo em Inglês | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1064046

RESUMO

This study sought to assess the influence of baseline right bundle branch block (RBBB) on all-cause and cardiovascular mortality as well as sudden cardiac death (SCD) among patients undergoing transcatheter aortic valve replacement (TAVR). Few data exist regarding the late clinical impact of pre-existing RBBB in TAVR recipients. A total of 3,527 patients (mean age 82 8 years, 50.1% men) were evaluated according to the presence of RBBB on baseline electrocardiography. Intraventricular conduction abnormalities were classified according to the American Heart Association, American College of Cardiology Foundation, and Heart Rhythm Society recommendations for standardization and interpretation of the electrocardiogram. TAVR complications and causes of death were defined according to Valve Academic Research Consortium 2 definitions. RBBB was present on baseline electrocardiography in 362 patients (10.3%) and associated with higher 30-day rates of permanent pacemaker implantation (PPI) (40.1% vs. 13.5%; p < 0.001) and death (10.2% vs. 6.9%; p » 0.024). At a mean follow-up of 20 18 months, pre-existing RBBB was independently associated with all-cause mortality (hazard ratio [HR]: 1.31; 95% confidence interval [CI]: 1.06 to 1.63; p » 0.014) and cardiovascular mortality (HR: 1.45; 95% CI: 1.11 to 1.89; p » 0.006) but not with SCD (HR: 0.71; 95% CI: 0.22 to 2.32; p » 0.57). Patients with pre-existing RBBB and without PPI at discharge from the index hospitalization had the highest 2-year risk for cardiovascular death (27.8%; 95% CI: 20.9% to 36.1%; log-rank p » 0.007). In a subanalysis of 1,245 patients without PPI at discharge from the index hospitalization and with complete follow-up regarding the need for PPI, pre-existing RBBB was independently associated with the composite of SCD and PPI (HR: 2.68; 95% CI: 1.16 to 6.17; p » 0.023)


Assuntos
Bloqueio de Ramo , Implante de Prótese de Valva Cardíaca , Morte Súbita Cardíaca
6.
J. Am. Coll. Cardiol ; 65(05): 437-448, 2015. ilus
Artigo em Inglês | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1063741

RESUMO

BACKGROUND Little evidence exists of the burden and predictors of cardiac death after transcatheter aortic valvereplacement (TAVR).OBJECTIVES The purpose of this study was to assess the incidence and predictors of cardiac death from advancedheart failure (HF) and sudden cardiac death (SCD) in a large patient cohort undergoing TAVR.METHODS The study included a total of 3,726 patients who underwent TAVR using balloon (57%) or self-expandable(43%) valves. Causes of death were defined according to the Valve Academic Research Consortium–2.RESULTS At a mean follow-up of 22 18 months, 155 patients had died due to advanced HF (15.2% of total deaths,46.1% of deaths from cardiac causes) and 57 had died due to SCD (5.6% of deaths, 16.9% of cardiac deaths). Baselinecomorbidities (chronic obstructive pulmonary disease, atrial fibrillation, left ventricular ejection fraction #40%, lowermean transaortic gradient, pulmonary artery systolic pressure >60 mm Hg; p 160 ms had a greater SCD risk (HR: 4.78, 95% CI: 1.56 to 14.63; p » 0.006).CONCLUSIONS Advanced HF and SCD accounted for two-thirds of cardiac deaths in patients after TAVR.Potentially modifiable or treatable factors leading to increased risk of mortality for HF and SCD were identified. Future.


Assuntos
Insuficiência Cardíaca , Morte Súbita , Substituição da Valva Aórtica Transcateter
SELEÇÃO DE REFERÊNCIAS