Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Intervalo de ano de publicação
1.
J Cardiovasc Electrophysiol ; 34(9): 1802-1807, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37473404

RESUMO

INTRODUCTION: Pulsed-field ablation (PFA) and the multielectrode radiofrequency balloon (RFB) are two novel ablation technologies to perform pulmonary vein isolation (PVI). It is currently unknown whether these technologies differ in lesion formation and lesion extent. We compared the acute lesion extent after PVI induced by PFA and RFB by measuring low-voltage area in high-density maps and the release of biomolecules reflecting cardiac injury. METHODS: PVI was performed with a pentaspline catheter (FARAPULSE) applying PFA or with the compliant multielectrode RFB (HELIOSTAR). Before and after PVI high-density mapping with CARTO 3 was performed. In addition, blood samples were taken before transseptal puncture and after post-PVI remapping and serum concentrations of high-sensitive Troponin I were quantified by immunoassay. RESULTS: Sixty patients undergoing PVI by PFA (n = 28, age 69 ± 12 year, 60% males, 39.3% persistent atrial fibrillation [AF]) or RFB (n = 32, age 65 ± 13 year, 53% males, 21.9% persistent AF) were evaluated. Acute PVI was achieved in all patients in both groups. Mean number of PFA pulses was 34.2 ± 4.5 and mean number RFB applications was 8.5 ± 3 per patient. Total posterior ablation area was significantly larger in PFA (20.7 ± 7.7 cm²) than in RFB (7.1 ± 2.09 cm²; p < .001). Accordingly, posterior ablation area for each PV resulted in larger lesions after PFA versus RFB (LSPV 5.2 ± 2.7 vs. 1.9 ± 0.8 cm², LIPV 5.5 ± 2.3 vs. 1.9 ± 0.8 cm², RSPV 4.7 ± 1.9 vs. 1.6 ± 0.5 cm², RIPV 5.3 ± 2.1 vs. 1.6 ± 0.7 cm,² respectively; p < .001). In a subset of 38 patients, increase of hsTropI was higher after PFA (625 ± 138 pg/mL, n = 28) versus RFB (148 ± 36 pg/mL, n = 10; p = .049) supporting the evidence of larger lesion extent by PFA. CONCLUSION: PFA delivers larger acute lesion areas and higher troponin release upon successful PVI than multielectrode RFB-based PVI in this single-center series.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Feminino , Veias Pulmonares/cirurgia , Resultado do Tratamento , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Catéteres
2.
Europace ; 25(5)2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-37116126

RESUMO

AIMS: A novel irrigated radiofrequency (RF) balloon (RFB) for pulmonary vein (PV) isolation (PVI) was released in selected centres. We pooled the procedural data on efficacy and safety of RFB-PVI from two high volume German centres. METHODS AND RESULTS: Consecutive patients with RFB procedures were enrolled. A 3D electroanatomical left atrial map guided the RFB navigation. Every RF delivery lasted 60 s, and duration was automatically reduced to 20 s for electrodes facing the posterior wall. Procedural data and post-procedural endoscopy data (<48 h) were analysed. Data from 140 patients were collected (57% male, 67 ± 11 years, 57% paroxysmal atrial fibrillation). There were 547 PVs identified, and 99.1% could be isolated using solely the RFB. Single-shot PVI was recorded in 330/547 (60%) PVs. Median time to isolation during the first application was 10 s (IQR 8-13). A total of 2.1 ± 1.8 applications per PV were delivered, with the left superior PV requiring more application compared to other PVs. Median procedure and fluoroscopy time were 77 min (61-99) and 13 min (10-17), respectively. Major safety events were recorded only in the first 25 cases at each centre and included 1/140(0.7%) cardiac tamponade, 1/140(0.7%) phrenic nerve palsy, and 2/140 strokes (1.4%). An oesophageal temperature rise was recorded in 81/547 (15%) PVs, and endoscopy detected oesophageal lesions in 7/85 (8%) patients undergoing endoscopy. CONCLUSION: The RFB showed a high efficacy allowing for fast PVI procedures, and 60% of PVs could be isolated at the first application. Most safety events were recorded during the learning phase. An oesophageal temperature monitoring is suggested: oesophageal lesions were detected in 8% of patients.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Masculino , Feminino , Resultado do Tratamento , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Átrios do Coração , Veias Pulmonares/cirurgia
3.
Circ J ; 87(7): 950-956, 2023 06 23.
Artigo em Inglês | MEDLINE | ID: mdl-37286488

RESUMO

BACKGROUND: A novel multielectrode radiofrequency balloon (RFB) catheter has been released for pulmonary vein isolation (PVI).Methods and Results: In this observational study consecutive patients with drug-refractory paroxysmal or persistent atrial fibrillation (AF) undergoing first-time PVI were enrolled in 2 high-volume ablation centers. All procedures were conducted in conjunction with a 3D-mapping system. Clinical, procedural and ablation parameters were systematically analyzed. 105 patients (58% male; 52% paroxysmal AF, 68±11.3 years mean age, left atrial volume index 38.6±14.8 mL/m2) were included. 241/412 (58.5%) PVs were successfully isolated with a single shot (SS), with a time-to-isolation of 11.6±8 s. Total number of radiofrequency applications was 892 (mean 2.2/PV), resulting in successful isolation of 408/412 (99%) PVs at the end of the procedure. Mean electrodes' impedance drop was significantly higher in the SS-PVI compared with non-SS applications (21.5±6.6 vs. 18.6±6.5 Ohm). Concordantly, higher temperature rise was observed in the SS vs. non-SS applications (10.9±4.9℃ vs. 9.6±4.7℃). CONCLUSIONS: In this multicenter real-world study, mean impedance drop and temperature rise were associated with successful SS-PVI applying the novel RFB catheter. These parameters may help to guide efficient usage of the new RF balloon.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Masculino , Feminino , Resultado do Tratamento , Ablação por Cateter/métodos , Fibrilação Atrial/cirurgia , Átrios do Coração , Veias Pulmonares/cirurgia , Catéteres , Recidiva
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA