3.
Toxics ; 10(3)2022 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-35324761

RESUMO

Poor indoor air quality can have adverse effects on human health, especially in susceptible populations. The aim of this study was to measure the concentrations of dioxide carbon (CO2), fine particulate matter (PM2.5) and total volatile organic compounds (TVOCs) in situ in private healthcare and elderly care facilities. These pollutants were continuously measured in two rooms of six private healthcare facilities (general practitioner's offices, dental offices and pharmacies) and four elderly care facilities (nursing homes) in two French urban areas during two seasons: summer and winter. The mean CO2 concentrations ranged from 764 ± 443 ppm in dental offices to 624 ± 198 ppm in elderly care facilities. The mean PM2.5 concentrations ranged from 13.4 ± 14.4 µg/m3 in dental offices to 5.7 ± 4.8 µg/m3 in general practitioner offices. The mean TVOC concentrations ranged from 700 ± 641 ppb in dental offices to 143 ± 239 ppb in general practitioner offices. Dental offices presented higher levels of indoor air pollutants, associated with the dental activities. Increasing the ventilation of these facilities by opening a window is probably an appropriate method for reducing pollutant concentrations and maintaining good indoor air quality.

4.
Toxics ; 10(3)2022 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-35324766

RESUMO

Previous studies have described the chemical pollution in indoor air of healthcare and care facilities. From these studies, the main objective of this work was to conduct a quantitative health risk assessment of the chronic inhalation of chemical compounds by workers in healthcare and elderly care facilities (hospitals, dental and general practitioner offices, pharmacies and nursing homes). The molecules of interest were 36 volatile and 13 semi-volatile organic compounds. Several professional exposure scenarios were developed in these facilities. The likelihood and severity of side effects that could occur were assessed by calculating the hazard quotient for deterministic effects, and the excess lifetime cancer risk for stochastic effects. No hazard quotient was greater than 1. Three compounds had a hazard quotient above 0.1: 2-ethyl-1-hexanol in dental and general practitioner offices, ethylbenzene and acetone in dental offices. Only formaldehyde presented an excess lifetime cancer risk greater than 1 × 10-5 in dental and general practitioner offices (maximum value of 3.8 × 10-5 for general practitioners). The health risk for chronic inhalation of most compounds investigated did not appear to be of concern. Some values tend to approach the acceptability thresholds justifying a reflection on the implementation of corrective actions such as the installation of ventilation systems.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA