1.
J Cardiovasc Electrophysiol ; 34(8): 1772-1775, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37431271

RESUMO

INTRODUCTION: We present the first worldwide use of pulsed-field ablation (PFA) for ventricular tachycardia (VT) ablation via a retrograde approach. METHODS: The patient had previously failed conventional ablation of an intramural circuit underneath the aortic valve. The same VT circuit was inducible during the procedure. The Farawave PFA catheter and Faradrive sheath were used to deliver PFA applications. RESULTS: Post ablation mapping demonstrated scar homogenization. There was no evidence of coronary spasm during PFA applications and no other complications occurred. VT was non-inducible post ablation and the patient has remained free of arrhythmia at follow-up. CONCLUSION: PFA for VT via a retrograde approach is feasible and effective.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Taquicardia Ventricular/etiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Resultado do Tratamento
2.
Europace ; 25(11)2023 11 02.
Artigo em Inglês | MEDLINE | ID: mdl-37738643

RESUMO

AIMS: Pulmonary vein isolation (PVI) is the cornerstone of catheter ablation for atrial fibrillation (AF). There are limited data on the PolarX Cryoballoon. The study aimed to establish the safety, efficacy, and feasibility of same day discharge for Cryoballoon PVI. METHODS AND RESULTS: Multi-centre study across 12 centres. Procedural metrics, safety profile, and procedural efficacy of the PolarX Cryoballoon with the Arctic Front Advance (AFA) Cryoballoon were compared in a cohort large enough to provide definitive comparative data. A total of 1688 patients underwent PVI with cryoablation (50% PolarX and 50% AFA). Successful PVI was achieved with 1677 (99.3%) patients with 97.2% (n = 1641) performed as day case procedures with a complication rate of <1%. Safety, procedural metrics, and efficacy of the PolarX Cryoballoon were comparable with the AFA cohort. The PolarX Cryoballoon demonstrated a nadir temperature of -54.6 ± 7.6°C, temperature at 30 s of -38.6 ± 7.2°C, time to -40°C of 34.1 ± 13.7 s, and time to isolation of 49.8 ± 33.2 s. Independent predictors for achieving PVI included time to reach -40°C [odds ratio (OR) 1.34; P < 0.001] and nadir temperature (OR 1.24; P < 0.001) with an optimal cut-off of ≤34 s [area under the curve (AUC) 0.73; P < 0.001] and nadir temperature of ≤-54.0°C (AUC 0.71; P < 0.001), respectively. CONCLUSIONS: This large-scale UK multi-centre study has shown that Cryoballoon PVI is a safe, effective day case procedure. PVI using the PolarX Cryoballoon was similarly safe and effective as the AFA Cryoballoon. The cryoablation metrics achieved with the PolarX Cryoballoon were different to that reported with the AFA Cryoballoon. Modified cryoablation targets are required when utilizing the PolarX Cryoballoon.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Resultado do Tratamento , Fatores de Tempo , Veias Pulmonares/cirurgia , Ablação por Cateter/métodos , Reino Unido , Recidiva
3.
J Cardiovasc Electrophysiol ; 31(7): 1640-1648, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32437007

RESUMO

BACKGROUND: No study to date has used high-density mapping to investigate the relationship between prior radiofrequency (RF) lesions for persistent atrial fibrillation (PsAF) ablation and subsequent atrial tachycardias (ATs). METHODS: From 41 consecutive patients who underwent AT ablation at a second procedure using an ultrahigh-density mapping system, 22 patients (38 ATs) were included as they also had complete maps with a multipolar catheter and three-dimensional (3D) mapping system at the time of the first PsAF ablation procedure. We, therefore, compared voltage maps from the first AF ablation procedure to those from the subsequent AT ablation procedure, as well as the lesion sets used for AF ablation vs the activation patterns in AT during the second procedure. RESULTS: In the 38 ATs, 211 of 285 analyzed atrial areas displayed low voltage area (LVA) (74%). Eighteen percent (38/211) existed before the index ablation for AF while 82% (173/211) were newly identified as LVA during the second procedure. Ninety-nine percent (172/173) of the newly developed LVA colocalized with RF lesions delivered for PsAF. Of the 38 ATs, 89.5% (34/38) AT circuits were associated with newly developed LVA due to RF lesions whilst 10.5% (4/38) AT circuits were associated with pre-existing LVA observed at the index procedure. No AT circuit was completely independent from index RF lesions in this series. CONCLUSIONS: Analysis of detailed 3D electroanatomical mapping demonstrates that most ATs after PsAF ablation are involving LVAs due to index RF lesions.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Taquicardia Supraventricular , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Técnicas Eletrofisiológicas Cardíacas , Humanos , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/cirurgia , Resultado do Tratamento
4.
Europace ; 22(8): 1252-1260, 2020 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-32594180

RESUMO

AIMS: We hypothesized that an epicardial approach using ethanol infusion in the vein of Marshall (EIVOM) may improve the result of ablation for perimitral flutter (PMF). METHODS AND RESULTS: We studied 103 consecutive patients with PMF undergoing high-resolution mapping. The first 71 were treated with radiofrequency (RF) ablation alone (RF-group), and the next 32 underwent EIVOM followed by RF on the endocardial and epicardial mitral isthmus (EIVOM/RF-group). Contact force was not measured during ablation. Acute and 1-year outcomes were compared. Flutter termination rates were similar between the RF-group (63/71, 88.7%) and EIVOM/RF-group (31/32, 96.8%, P = 0.27). Atrial tachycardia (AT) terminated with EIVOM alone in 22/32 (68.6%) in the EIVOM/RF-group. Bidirectional block of mitral isthmus was always achieved in the EIVOM/RF-group, but significantly less frequently achieved in the RF-group (62/71, 87.3%; P = 0.05). Median RF duration for AT termination/conversion was shorter [0 (0-6) s in the EIVOM/RF-group than 312 (55-610) s in the RF-group, P < 0.0001], as well as for mitral isthmus block in the EIVOM/RF-group [246 (0-663) s] than in the RF-group [900 (525-1310) s, P < 0.0001]. Pericardial effusion was observed in 1/32 (3.2%) in EIVOM/RF-group and 5/71 (7.0%) in RF-group (P = 0.66); two in RF-group required drainage and one of them developed subsequent ischaemic stroke. One-year follow-up demonstrated fewer recurrences in the EIVOM/RF-group [6/32 (18.8%)] than in the RF-group [29/71 (40.8%), P = 0.04]. By multivariate analysis, only EIVOM was significantly associated with less AT recurrence (hazard ratio = 0.35, P = 0.018). CONCLUSION: Ethanol infusion in the vein of Marshall may reduce RF duration required for PMF termination as well as for mitral isthmus block without severe complications, and the mid-term outcome may be improved by this approach.


Assuntos
Fibrilação Atrial , Flutter Atrial , Isquemia Encefálica , Ablação por Cateter , Acidente Vascular Cerebral , Fibrilação Atrial/cirurgia , Flutter Atrial/diagnóstico , Flutter Atrial/tratamento farmacológico , Flutter Atrial/cirurgia , Etanol , Humanos , Resultado do Tratamento
5.
Heart ; 109(5): 364-371, 2023 02 14.
Artigo em Inglês | MEDLINE | ID: mdl-36396438

RESUMO

OBJECTIVE: We aimed to compare cryoballoon pulmonary vein isolation (PVI) with standard radiofrequency cavotricuspid isthmus (CTI) ablation as first-line treatment for typical atrial flutter (AFL). METHODS: Cryoballoon Pulmonary Vein Isolation as First-Line Treatment for Typical Atrial Flutter was an international, multicentre, open with blinded assessment trial. Patients with CTI-dependent AFL and no documented atrial fibrillation (AF) were randomised to either cryoballoon PVI alone or radiofrequency CTI ablation. Primary efficacy outcome was time to first recurrence of sustained (>30 s) symptomatic atrial arrhythmia (AF/AFL/atrial tachycardia) at 12 months as assessed by continuous monitoring with an implantable loop recorder. Primary safety outcome was a composite of death, stroke, tamponade requiring drainage, atrio-oesophageal fistula, pacemaker implantation, serious vascular complications or persistent phrenic nerve palsy. RESULTS: Trial recruitment was halted at 113 of the target 130 patients because of the SARS-CoV-2 pandemic (PVI, n=59; CTI ablation, n=54). Median age was 66 (IQR 61-71) years, with 98 (86.7%) men. At 12 months, the primary outcome occurred in 11 (18.6%) patients in the PVI group and 9 (16.7%) patients in the CTI group. There was no significant difference in the primary efficacy outcome between the groups (HR 1.11, 95% CI 0.46 to 2.67). AFL recurred in six (10.2%) patients in the PVI arm and one (1.9%) patient in the CTI arm (p=0.116). Time to occurrence of AF of ≥2 min was significantly reduced with cryoballoon PVI (HR 0.46, 95% CI 0.25 to 0.85). The composite safety outcome occurred in four patients in the PVI arm and three patients in the CTI arm (p=1.000). CONCLUSION: Cryoballoon PVI as first-line treatment for AFL is equally effective compared with standard CTI ablation for preventing recurrence of atrial arrhythmia and better at preventing new-onset AF. TRIAL REGISTRATION NUMBER: NCT03401099.


Assuntos
Fibrilação Atrial , Flutter Atrial , COVID-19 , Ablação por Cateter , Veias Pulmonares , Taquicardia Supraventricular , Masculino , Humanos , Idoso , Feminino , Flutter Atrial/diagnóstico , Flutter Atrial/cirurgia , Flutter Atrial/epidemiologia , Veias Pulmonares/cirurgia , Ablação por Cateter/efeitos adversos , COVID-19/complicações , SARS-CoV-2 , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/epidemiologia , Resultado do Tratamento , Recidiva
6.
J Interv Card Electrophysiol ; 65(2): 509-518, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35794439

RESUMO

PURPOSE: Local impedance (LI) measurement from an ablation catheter is useful in predicting lesion size and acute success of pulmonary vein isolation (PVI). The LI variation can be described by absolute LI drop (ΔLID) or ΔLID/initial LI (%LID). We evaluated the utility of these parameters in predicting acute lesion durability during PVI using a novel catheter capable of measuring both LI and contact force (CF). METHODS: PVI with a targeted CF, power, and duration was performed in 23 consecutive patients with paroxysmal atrial fibrillation. LI was blinded to operators during ablation. Parameters for each RF application were collected and compared for acute successful lesions and gaps. RESULTS: A total of 1633 RF applications including 97 (5.9%) gap lesions were analyzed. Successful lesions were more frequently observed at non-carinal sites and those with higher contact force, FTI, initial LI, and larger variation of LI and generator impedance (GI). Multivariate analysis demonstrated that absolute GI drop (ΔGID) [OR 1.09 (1.04-1.15), p < 0.001], ΔLID [1.12 (1.09-1.16), p < 0.001], ΔGID/initial GI (%GID) [OR 1.04 (1.01-1.07), p = 0.01], and %LID [OR 1.15 (1.12-1.28), p < 0.001] were significantly associated with successful lesions, and carinal site [OR 0.15(0.09-0.24), p < 0.001] was significantly related to gaps. Both ΔLID and %LID equally predicted the acute durability of lesions during PVI. ΔLID ≥ 24Ω and %LID ≥ 15% at the carina, and ΔLID ≥ 21Ω and %LID ≥ 14% at non-carinal sites significantly predicted acute successful lesions with negative predictive values of 93-99%. CONCLUSIONS: Both ΔLID and %LID were equally useful in predicting acute successful lesions during PVI. Larger cut-off values should be applied to carinal sites.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Veias Pulmonares/cirurgia , Impedância Elétrica , Fibrilação Atrial/cirurgia , Catéteres , Resultado do Tratamento
7.
Sci Rep ; 12(1): 9139, 2022 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-35650230

RESUMO

Ultra-high-density (UHD) mapping can improve scar area detection and fast activation mapping in patients undergoing catheter ablation of ventricular tachycardia (VT). The aim of the present study was to compare the outcome after VT ablation guided by UHD and conventional point-by-point 3D-mapping. The acute and long-term ablation outcome of 61 consecutive patients with UHD mapping (64-electrode mini-basket catheter) was compared to 61 consecutive patients with conventional point-by-point 3D-mapping using a 3.5 mm tip catheter. Patients, whose ablation was guided by UHD mapping had an improved 24-months outcome in comparison to patients with conventional mapping (cumulative incidence estimate of the combination of recurrence or disease-related death of 52.4% (95% confidence interval (CI) [36.9-65.7]; recurrence: n = 25; disease-related death: n = 4) versus 69.6% (95% CI [55.9-79.8]); recurrence: n = 31; disease-related death n = 11). In a cause-specific Cox proportional hazards model, UHD mapping (hazard ratio (HR) 0.623; 95% CI [0.390-0.995]; P = 0.048) and left ventricular ejection fraction > 30% (HR 0.485; 95% CI [0.290-0.813]; P = 0.006) were independently associated with lower rates of recurrence or disease-related death. Other procedural parameters were similar in both groups. In conclusion, UHD mapping during VT ablation was associated with fewer VT recurrences or disease-related deaths during long-term follow-up in comparison to conventional point-by-point mapping. Complication rates and other procedural parameters were similar in both groups.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Mapeamento Potencial de Superfície Corporal , Ablação por Cateter/efeitos adversos , Humanos , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
9.
J Am Heart Assoc ; 8(15): e012482, 2019 08 06.
Artigo em Inglês | MEDLINE | ID: mdl-31378121

RESUMO

Background Fat deposition (FD) is part of the healing process after myocardial infarction. The characteristics of FD and its impact on the outcome in patients undergoing ventricular tachycardia (VT) ablation have not been thoroughly studied. Methods and Results We studied consecutive patients undergoing post-myocardial infarction VT ablation with pre-procedural cardiac computed tomography. FD was defined as intra-myocardial attenuation ≤ -30 HU on computed tomography. Clinical, anatomical, and post-procedural outcome was assessed in the overall population. Electrophysiological characteristics were assessed is a subgroup of patients with high-density electro-anatomical maps. Sixty-nine patients were included (66±12 years). FD was detected in 44 (64%) patients. The presence of FD related to scar age (odds ratio [OR]: 1.14 per year; P=0.001) and scar extent (OR: 1.27 per segment; P=0.02). On electro-anatomical maps, FD was characterized by lower bipolar amplitude (P<0.001) and prolonged electrogram duration (P<0.001). Although the proportion of local abnormal ventricular activation was similar (P=0.22), local abnormal ventricular activation showed lower amplitude (P<0.001) and were more delayed (P<0.001) in scars with FD. After a mean follow-up of 26 months, patients with FD experienced a worse outcome including all-cause mortality and VT recurrence (70% versus 28%, P log rank=0.009). On multivariate analysis, FD (hazard ratio=2.69; 95% CI, 1.12-6.46; P=0.027) and left ventricular systolic dysfunction (hazard ratio=2.57; 95% CI, 1.13-5.85; P=0.024) were independent predictors of adverse outcomes. Conclusions FD in patients with post-myocardial infarction VT undergoing catheter ablation relates to scar age and size and may be a marker of adverse outcomes including all-cause mortality and VT recurrence.


Assuntos
Tecido Adiposo , Ablação por Cateter , Cicatriz/etiologia , Cicatriz/fisiopatologia , Infarto do Miocárdio/complicações , Infarto do Miocárdio/fisiopatologia , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/cirurgia , Tecido Adiposo/patologia , Idoso , Cicatriz/patologia , Técnicas Eletrofisiológicas Cardíacas , Fenômenos Eletrofisiológicos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/patologia , Prognóstico , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS