Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Intervalo de ano de publicação
1.
Zhonghua Yi Xue Za Zhi ; 101(2): 108-114, 2021 Jan 12.
Artigo em Chinês | MEDLINE | ID: mdl-33455125

RESUMO

Objective: To perform a comprehensive comparison on the therapeutic effects of unilateral 31.5 mm and 28 mm cochlear implantation (CI) on the post-operative hearing rehabilitation outcomes, including hearing threshold, speech recognition and quality of life, in patients with bilateral sensorineural hearing loss. Methods: A total of 26 patients [12 males, 14 females, aged 19-71 (43±16) years] diagnosed with bilateral severe-to-profound sensorineural hearing loss at Peking Union Medical College Hospital from April 2018 to August 2019 were included. Patients underwent temporal bone high resolution CT (HRCT), based on which the electrode lengths were calculated using OTOPLAN. Eleven and fifteen ears were implanted with MED-EL Flex 31.5 mm and Flex 28 mm electrode arrays respectively, via round window approach under minimally invasive surgery. The patients were followed up regularly for up to 2 years. At each follow-up, aided hearing threshold, speech recognition in quiet and noise, and Nijmegen Cochlear Implantation Questionnaire (NICQ) scores were evaluated and compared. Results: Post-operative hearing thresholds were (46.5±3.4) dB and (48.5±2.2) dB in patients implanted with MED-EL Flex 31.5 mm and Flex 28 mm electrode arrays, respectively, with no statistically significant difference (P=0.074). Both hearing thresholds and speech recognition demonstrated significant post-operative improvement compared with pre-operative results. Hearing thresholds after 1-year post-operation were (32.1±1.2) dB and (32.5±0.9) dB, respectively (P=0.355). Patients implanted with Flex 31.5 mm electrode scored significantly higher at speech recognition under 65 dB sound pressure level (SPL) at most of the follow-ups (All P<0.05). Speech recognition in noise (S/N=10 dB) was also improved in patients implanted with Flex 31.5 mm electrode. All sub-divisions of the NICQ demonstrated significant post-operative improvement, and no significant difference between the 2 groups was observed apart from the"self-confidence"sub-division. Conclusions: Selection of MED-EL Flex 31.5 mm and 28 mm implantation based on pre-operative OTOPLAN evaluation can both bring significant improvements to patients' hearing and quality of life. Flex 31.5 mm electrode can potentially provide better speech recognition within a certain period after surgery.


Assuntos
Implante Coclear , Implantes Cocleares , Perda Auditiva Neurossensorial , Percepção da Fala , Adulto , Idoso , Feminino , Perda Auditiva Neurossensorial/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Qualidade de Vida , Resultado do Tratamento , Adulto Jovem
2.
Artigo em Chinês | MEDLINE | ID: mdl-31446700

RESUMO

Summary Chiari malformation type Ⅰ(CMI) is a disorder characterized by tonsilla cerebelli herniating into an underdeveloped posterior cranial fossa, hearing loss is often covered by more striking neurological symptoms. Hearing loss in this syndrome is not specific in terms of gender side, degree, age of onset, and progression. The hearing improvement after posterior fossa decompression is controversial on the basis of literature, while satisfactory result was obtained after cochlear implantation in the patient reported here, who was diagnosed as CMI with hearing loss as the main symptom. Therefore, after ensuring the integrity of the auditory pathway, cochlear implantation may be considered in CMI patients with bilateral severe or profound without other severe neurological symptoms.


Assuntos
Malformação de Arnold-Chiari/complicações , Implante Coclear , Surdez/etiologia , Surdez/cirurgia , Fossa Craniana Posterior/patologia , Audição , Humanos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA