Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
J Med Assoc Thai ; 99(9): 1052-6, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29927212

RESUMO

We report a case of ruptured head of posteromedial papillary muscle and prolapse of anterior mitral valve leaflet that caused severe mitral regurgitation (MR) and cardiogenic shock as a complication of inferior wall myocardial infarction in an 80-year-old man. Emergency coronary angiogram revealed thrombotic occlusion at proximal right coronary artery. Transesophageal echocardiogram revealed ruptured head of posteromedial papillary muscle and prolapse of anterior mitral valve leaflet causing severe MR. After percutaneous coronary intervention with bare metal stent, the patient underwent mitral valve repair with saphenous vein graft to the posterolateral branch of the right coronary artery. The patient was discharged from hospital on day 14 of admission.


Assuntos
Angiografia Coronária/métodos , Ecocardiografia Transesofagiana/métodos , Infarto Miocárdico de Parede Inferior/complicações , Infarto Miocárdico de Parede Inferior/diagnóstico por imagem , Choque Cardiogênico/diagnóstico por imagem , Choque Cardiogênico/etiologia , Idoso de 80 Anos ou mais , Humanos , Infarto Miocárdico de Parede Inferior/cirurgia , Masculino , Valva Mitral/diagnóstico por imagem , Valva Mitral/lesões , Valva Mitral/cirurgia , Músculos Papilares/diagnóstico por imagem , Músculos Papilares/lesões , Músculos Papilares/cirurgia , Intervenção Coronária Percutânea/métodos , Ruptura , Stents , Resultado do Tratamento
2.
Echocardiography ; 30(8): E231-5, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23710761

RESUMO

We present a case of concomitant left ventricle (LV) to right atrial shunt (Gerbode-like defect) and anterior mitral leaflet perforation in a 32-year-old male after aortic valve replacement for infective endocarditis of bicuspid aortic valve. This case emphasises that intra-operative transesophageal echocardiography is a sine qua non for valvular surgical procedures.


Assuntos
Aortite/diagnóstico por imagem , Endocardite/diagnóstico por imagem , Implante de Prótese de Valva Cardíaca/efeitos adversos , Valva Mitral/diagnóstico por imagem , Valva Mitral/lesões , Ferimentos Penetrantes/diagnóstico por imagem , Ferimentos Penetrantes/etiologia , Adulto , Aortite/complicações , Aortite/cirurgia , Endocardite/complicações , Endocardite/cirurgia , Humanos , Masculino , Resultado do Tratamento , Ultrassonografia
3.
Ann Thorac Surg ; 110(3): e153-e155, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32142816

RESUMO

Inferior vena cava filters are used for patients with pulmonary embolism or those with risk of embolization. Here we present a case of a 38-year-old man who underwent placement of an inferior vena cava filter because of deep vein thrombosis. The operating arm fractured and embolized to the posteromedial papillary muscle of mitral valve and the posterior inferior wall of the left ventricle through right atrium and atrioventricular septum, leading to large symptomatic mitral and tricuspid insufficiency and pericardial tamponade. Here we report a rare case where the filter migrated to the left ventricle and destroyed the mitral valve.


Assuntos
Migração de Corpo Estranho/diagnóstico , Ventrículos do Coração , Insuficiência da Valva Mitral/etiologia , Valva Mitral/lesões , Insuficiência da Valva Tricúspide/etiologia , Filtros de Veia Cava/efeitos adversos , Adulto , Tamponamento Cardíaco/diagnóstico , Tamponamento Cardíaco/etiologia , Tamponamento Cardíaco/cirurgia , Migração de Corpo Estranho/complicações , Migração de Corpo Estranho/cirurgia , Humanos , Masculino , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/cirurgia , Embolia Pulmonar/etiologia , Embolia Pulmonar/prevenção & controle , Insuficiência da Valva Tricúspide/diagnóstico , Insuficiência da Valva Tricúspide/cirurgia , Veia Cava Inferior , Trombose Venosa/complicações
7.
Ann Thorac Cardiovasc Surg ; 19(3): 225-7, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23232302

RESUMO

We here present the case of a 35-year-old man with mitral valve paravalvular abnormal tunnel with mitral regurgitation caused by anterior chest trauma. The abnormal tunnel is between left ventricular and left artrial. We sutured the tunnel with a patch from the left atrial side. Meanwhile, we performed the mitral valve annuoplasty because of the mitral regurgitation accompanied. The postoperation and the 12th month follow up were uneventful.


Assuntos
Traumatismos Cardíacos/etiologia , Insuficiência da Valva Mitral/etiologia , Adulto , Ecocardiografia Doppler em Cores , Ecocardiografia Tridimensional , Ecocardiografia Transesofagiana , Traumatismos Cardíacos/diagnóstico por imagem , Traumatismos Cardíacos/cirurgia , Implante de Prótese de Valva Cardíaca , Humanos , Masculino , Valva Mitral/lesões , Anuloplastia da Valva Mitral , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Técnicas de Sutura , Resultado do Tratamento
11.
Interact Cardiovasc Thorac Surg ; 8(2): 235-7, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19038982

RESUMO

There have been several reports of a malpositioned pacemaker lead as a complication in pacemaker implantation. Herein we report a rare case of a malpositioned pacemaker lead in the left ventricle, which could occur in patients with cardiac structural abnormalities. A 70-year-old woman, who had undergone implantation of a pacemaker at the left subclavian position for complete atrioventricular block five years previously, was evaluated because of dyspnea and low grade fever. Echocardiography revealed a congenital atrial septal defect through which the lead was placed into the left ventricle. Whereas percuteneous lead removal seemed to be full of risk with concerns of thromboembolic events and infective endocarditis, the patient was referred to our hospital for surgical removal of the wire and closure of the defect. The lead was a screw-in type and removed and was extracted in the theatre using radiography. Intraoperatively it was found that the lead was positioned in the left ventricle apex after perforating the posterior mitral leaflet. Repair of the mitral valve perforation and closure of the septal defect and epicardial pacemaker lead implantation was performed. This case demonstrated the possibility of malposition of the pacemaker lead to the left ventricle in a transvenous pacemaker implantation procedure, which may lead to thromboembolic complication or infective endocarditis, and the pre-eminent role of echocardiography in the diagnosis of cardiac structural abnormalities. A malpositioned pacemaker lead in the left ventricle is a rare complication that can occur in patients with cardiac structural abnormalities. Lateral chest roentgenogram and echocardiography is efficient in preventing this complication. The removal of the lead in concerns of thromboembolic events and infection is preferable.


Assuntos
Migração de Corpo Estranho/etiologia , Traumatismos Cardíacos/etiologia , Comunicação Interatrial/complicações , Valva Mitral/lesões , Marca-Passo Artificial/efeitos adversos , Idoso , Bloqueio Atrioventricular/complicações , Bloqueio Atrioventricular/terapia , Procedimentos Cirúrgicos Cardíacos , Remoção de Dispositivo , Ecocardiografia , Feminino , Migração de Corpo Estranho/patologia , Migração de Corpo Estranho/cirurgia , Traumatismos Cardíacos/patologia , Traumatismos Cardíacos/cirurgia , Comunicação Interatrial/patologia , Comunicação Interatrial/cirurgia , Ventrículos do Coração/patologia , Humanos , Valva Mitral/cirurgia , Radiografia Torácica , Resultado do Tratamento
12.
Tex Heart Inst J ; 36(3): 252-4, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19568400

RESUMO

Blunt thoracoabdominal trauma is most often caused by high-velocity motor-vehicle accidents or by falls from a height. The clinical spectrum of cardiac injuries arising from this type of trauma varies from myocardial contusion to valvular rupture. Intracardiac valvular rupture is rarely observed, and few cases have been reported. The youngest of the patients in cases reported to date was 6 years of age. Here we report the case of a 2(1/2)year-old child, who sustained mitral valve insufficiency due to isolated rupture of the posterior mitral papillary muscle, which developed after a domestic accident.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Traumatismos Cardíacos/cirurgia , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Músculos Papilares/cirurgia , Ferimentos não Penetrantes/cirurgia , Pré-Escolar , Ecocardiografia Doppler em Cores , Traumatismos Cardíacos/diagnóstico por imagem , Traumatismos Cardíacos/etiologia , Humanos , Masculino , Valva Mitral/diagnóstico por imagem , Valva Mitral/lesões , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/etiologia , Músculos Papilares/diagnóstico por imagem , Músculos Papilares/lesões , Pericárdio/transplante , Técnicas de Sutura , Resultado do Tratamento , Ferimentos não Penetrantes/diagnóstico por imagem , Ferimentos não Penetrantes/etiologia
13.
J Am Soc Echocardiogr ; 21(5): 512.e5-7, 2008 May.
Artigo em Inglês | MEDLINE | ID: mdl-17931830

RESUMO

An inadvertently placed pacing lead in the left ventricle (LV) is a rare and often underdiagnosed complication of pacemaker implantation. We present a case of a 73-year-old woman who was evaluated for dyspnea, 10 years after transvenous pacemaker implantation. Transthoracic and transesophageal echocardiography revealed a secundum atrial septal defect through which the ventricular pacing lead was placed into the LV. Whereas percutaneous extraction of the lead seemed too full of risk, the patient was referred for surgical removal of the wire and closure of the defect. Intraoperatively it was found that the lead had perforated the posterior mitral valve leaflet before it was positioned into the LV apex. Therefore, the wire could only be partially removed during surgery and two lead fragments remained in the LV for which anticoagulation therapy was initiated. This case demonstrates the pre-eminent role of echocardiography in the diagnosis of cardiac structural abnormalities.


Assuntos
Eletrodos Implantados/efeitos adversos , Valva Mitral/diagnóstico por imagem , Valva Mitral/lesões , Marca-Passo Artificial/efeitos adversos , Ferimentos Penetrantes/diagnóstico por imagem , Ferimentos Penetrantes/etiologia , Idoso , Feminino , Humanos , Doença Iatrogênica/prevenção & controle , Doenças Raras/diagnóstico por imagem , Doenças Raras/etiologia , Ultrassonografia
15.
In. Cunha, Aparecida Irian Guidugli; Santos, Jane Fischer Vital dos; Balbieris, Vivianae da Conceição; Silva, Edna Valéria da; Cunha, Aparecida Irian Guidugli. Instituto Dante Pazzanese de Cardiologia. BrasilSantos, Jane Fischer Vital dos. Instituto Dante Pazzanese de Cardiologia. BrasilBalbieris, Vivianae da Conceição. Instituto Dante Pazzanese de Cardiologia. BrasilSilva, Edna Valéria da. Instituto Dante Pazzanese de Cardiologia. Brasil. A Enfermagem na Cardiologia Invasiva. São Paulo, Atheneu, 2007. p.71-80, ilus.
Monografia em Português | LILACS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1070008
16.
In. Sousa, Amanda GMR; Piegas, Leopoldo S; Sousa, J Eduardo MR. Série Monografias Dante Pazzanese. Rio de Janeiro, Revinter, 2000. p.92, ilus, ilus.
Não convencional em Português | LILACS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1069390

RESUMO

A abordagem cirúrgica conservadora da valva mitral é amplamente analisada nesta monografia. A plastia mitral, cada vez mais, se estabelece como tratamento de primeira escolha para a regurgitação mitral de qualquer etiologia. O crescimento dessa aceitação deve-se à superioridade da plastia mitral em termos de morbidade e mortalidade quando comparada aos substitutos valvares, fato esse amplamente respaldado pela literatura. Ao rever brevemente o histórico da plastia mitral, percebemos a importância de Carpentier e a atualidade de suas contribuições tão originais, bem como a visão de longo alcance e a proximidade com o método cintífico de Cosgrove...


Assuntos
Humanos , Cirurgia Torácica/métodos , Cirurgia Torácica/tendências , Insuficiência da Valva Mitral/mortalidade , Insuficiência da Valva Mitral/prevenção & controle , Valva Mitral/cirurgia , Valva Mitral/lesões , Ecocardiografia/métodos , Próteses Valvulares Cardíacas/normas , Próteses Valvulares Cardíacas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA