Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
Más filtros













Base de datos
Intervalo de año de publicación
1.
Analyst ; 149(10): 2812-2825, 2024 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-38644740

RESUMEN

Acute myeloid leukemia (AML) is the most common form of acute leukemia in adults and associated with poor prognosis. Unfortunately, most of the patients that achieve clinical complete remission after the treatment will ultimately relapse due to the persistence of minimal residual disease (MRD), that is not measurable using conventional technologies in the clinic. Microfluidics is a potential tool to improve the diagnosis by providing early detection of MRD. Herein, different designs of microfluidic devices were developed to promote lateral and vertical mixing of cells in microchannels to increase the contact area of the cells of interest with the inner surface of the device. Possible interactions between the cells and the surface were studied using fluid simulations. For the isolation of leukemic blasts, a positive selection strategy was used, targeting the cells of interest using a panel of specific biomarkers expressed in immature and aberrant blasts. Finally, once the optimisation was complete, the best conditions were used to process patient samples for downstream analysis and benchmarking, including phenotypic and genetic characterisation. The potential of these microfluidic devices to isolate and detect AML blasts may be exploited for the monitoring of AML patients at different stages of the disease.


Asunto(s)
Separación Celular , Leucemia Mieloide Aguda , Humanos , Leucemia Mieloide Aguda/patología , Leucemia Mieloide Aguda/sangre , Separación Celular/métodos , Separación Celular/instrumentación , Dispositivos Laboratorio en un Chip , Técnicas Analíticas Microfluídicas/métodos , Técnicas Analíticas Microfluídicas/instrumentación
2.
RSC Adv ; 14(18): 12397-12406, 2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38633492

RESUMEN

The long-term performance of metal halide perovskite solar cells (PSCs) can be significantly improved by tuning the surface characteristics of the perovskite layers. Herein, low-temperature-processed ethylenediaminetetraacetic acid (EDTA)-complexed SnO2 (E-SnO2) is successfully employed as an electron transport layer (ETL) in PSCs, enhancing the efficiency and stability of the devices. The effects of EDTA treatment on SnO2 are investigated for different concentrations: comparing the solar cells' response with 15%-2.5% SnO2 and E-SnO2 based ETLs, and it was found that 7.5% E-SnO2 provided the best results. The improved surface properties of the perovskite layer on E-SnO2 are attributed to the presence of small amount of PbI2 which contributes to passivate the defects at the grain boundaries and films' surface. However, for the excess PbI2 based devices, photocurrent dropped, which could be attributed to the generation of shallow traps due to excess PbI2. The better alignment between the Fermi level of E-SnO2 and the conduction band of perovskite is another favorable aspect that enables increased open-circuit potential (VOC), from 0.82 V to 1.015 V, yielding a stabilized power conversion efficiency of 15.51%. This complex ETL strategy presented here demonstrates the enormous potential of E-SnO2 as selective contact to enhance the perovskite layer properties and thereby allow stable and high-efficiency PSCs.

3.
Analyst ; 148(17): 4053-4063, 2023 Aug 21.
Artículo en Inglés | MEDLINE | ID: mdl-37529888

RESUMEN

Early and accurate detection of infection by pathogenic microorganisms, such as Plasmodium, the causative agent of malaria, is critical for clinical diagnosis and ultimately determines the patient's outcome. We have combined a polystyrene-based microfluidic device with an immunoassay which utilises Surface-Enhanced Raman Spectroscopy (SERS) to detect malaria. The method can be easily translated to a point-of-care testing format and shows excellent sensitivity and specificity, when compared to the gold standard for laboratorial detection of Plasmodium infections. The device can be fabricated in less than 30 min by direct patterning on shrinkable polystyrene sheets of adaptable three-dimensional microfluidic chips. To validate the microfluidic system, samples of P. falciparum-infected red blood cell cultures were used. The SERS-based immunoassay enabled the detection of 0.0012 ± 0.0001% parasitaemia in a P. falciparum-infected red blood cell culture supernatant, an ∼7-fold higher sensitivity than that attained by most rapid diagnostic tests. Our approach successfully overcomes the main challenges of the current Plasmodium detection methods, including increased reproducibility, sensitivity, and specificity. Furthermore, our system can be easily adapted for detection of other pathogens and has excellent properties for early diagnosis of infectious diseases, a decisive step towards lowering their high burden on healthcare systems worldwide.


Asunto(s)
Malaria Falciparum , Malaria , Parásitos , Plasmodium , Humanos , Animales , Poliestirenos , Plasmodium falciparum , Reproducibilidad de los Resultados , Malaria/diagnóstico , Malaria Falciparum/diagnóstico , Sensibilidad y Especificidad , Dispositivos Laboratorio en un Chip
4.
Sensors (Basel) ; 23(10)2023 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-37430841

RESUMEN

Microfluidic-based platforms have become a hallmark for chemical and biological assays, empowering micro- and nano-reaction vessels. The fusion of microfluidic technologies (digital microfluidics, continuous-flow microfluidics, and droplet microfluidics, just to name a few) presents great potential for overcoming the inherent limitations of each approach, while also elevating their respective strengths. This work exploits the combination of digital microfluidics (DMF) and droplet microfluidics (DrMF) on a single substrate, where DMF enables droplet mixing and further acts as a controlled liquid supplier for a high-throughput nano-liter droplet generator. Droplet generation is performed at a flow-focusing region, operating on dual pressure: negative pressure applied to the aqueous phase and positive pressure applied to the oil phase. We evaluate the droplets produced with our hybrid DMF-DrMF devices in terms of droplet volume, speed, and production frequency and further compare them with standalone DrMF devices. Both types of devices enable customizable droplet production (various volumes and circulation speeds), yet hybrid DMF-DrMF devices yield more controlled droplet production while achieving throughputs that are similar to standalone DrMF devices. These hybrid devices enable the production of up to four droplets per second, which reach a maximum circulation speed close to 1540 µm/s and volumes as low as 0.5 nL.


Asunto(s)
Microfluídica , Ácidos Nucleicos , Bioensayo , Dispositivos Laboratorio en un Chip , Tecnología
5.
Lab Chip ; 23(14): 3238-3244, 2023 Jul 12.
Artículo en Inglés | MEDLINE | ID: mdl-37341773

RESUMEN

Droplet-based microfluidic technology is a powerful tool for generating large numbers of monodispersed nanoliter-sized droplets for ultra-high throughput screening of molecules or single cells. Yet further progress in the development of methods for the real-time detection and measurement of passing droplets is needed for achieving fully automated systems and ultimately scalability. Existing droplet monitoring technologies are either difficult to implement by non-experts or require complex experimentation setups. Moreover, commercially available monitoring equipment is expensive and therefore limited to a few laboratories worldwide. In this work, we validated for the first time an easy-to-use, open-source Bonsai visual programming language to accurately measure in real-time droplets generated in a microfluidic device. With this method, droplets are found and characterized from bright-field images with high processing speed. We used off-the-shelf components to achieve an optical system that allows sensitive image-based, label-free, and cost-effective monitoring. As a test of its use we present the results, in terms of droplet radius, circulation speed and production frequency, of our method and compared its performance with that of the widely-used ImageJ software. Moreover, we show that similar results are obtained regardless of the degree of expertise. Finally, our goal is to provide a robust, simple to integrate, and user-friendly tool for monitoring droplets, capable of helping researchers to get started in the laboratory immediately, even without programming experience, enabling analysis and reporting of droplet data in real-time and closed-loop experiments.

6.
Nanomaterials (Basel) ; 13(1)2023 Jan 03.
Artículo en Inglés | MEDLINE | ID: mdl-36616119

RESUMEN

The present contribution aims to enhance solar cells' performance via the development of advanced luminescent down-shifting based on encapsulated nanostructured perovskite materials. Here, thin films of inorganic lead halide (CsPbBr3) perovskite nanocrystal luminophores were synthetized, by hot-injection, deposited on glass substrates by spin-coating, and encapsulated with parylene type C, via chemical vapor deposition, to protect and stabilize the films. The optical properties of these thin films were characterized by absorption, emission and 2D contour spectra, their structure by X-ray diffraction and X-ray photoelectron spectroscopy, and the morphology by Scanning Transmission Electron microscopy. I-V curve and spectral response nanocrystalline silicon photovoltaic (nc-Si:H PV) cells were studied in the absence and presence of the perovskite and parylene luminescent down-shifting layers. The incorporation of the CsPbBr3 nanocrystals and their encapsulation with the parylene type C polymeric coating led to an increase in the current generated and the spectral response of the PV cells in the regime of the nanocrystals' fluorescence emission. A 3.1% increase in the short circuit current density and a 5.6% increase in the power conversion efficiency were observed.

7.
Discov Mater ; 2(1): 12, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36536830

RESUMEN

A new avenue has opened up for applications of surface-enhanced Raman spectroscopy (SERS) in the biomedical field, mainly due to the striking advantages offered by SERS tags. SERS tags provide indirect identification of analytes with rich and highly specific spectral fingerprint information, high sensitivity, and outstanding multiplexing potential, making them very useful in in vitro and in vivo assays. The recent and innovative advances in nanomaterial science, novel Raman reporters, and emerging bioconjugation protocols have helped develop ultra-bright SERS tags as powerful tools for multiplex SERS-based detection and diagnosis applications. Nevertheless, to translate SERS platforms to real-world problems, some challenges, especially for clinical applications, must be addressed. This review presents the current understanding of the factors influencing the quality of SERS tags and the strategies commonly employed to improve not only spectral quality but the specificity and reproducibility of the interaction of the analyte with the target ligand. It further explores some of the most common approaches which have emerged for coupling SERS with microfluidic technologies, for biomedical applications. The importance of understanding microfluidic production and characterisation to yield excellent device quality while ensuring high throughput production are emphasised and explored, after which, the challenges and approaches developed to fulfil the potential that SERS-based microfluidics have to offer are described.

8.
Nanomaterials (Basel) ; 12(19)2022 Sep 20.
Artículo en Inglés | MEDLINE | ID: mdl-36234397

RESUMEN

The inexorable increase of energy demand and the efficiency bottleneck of monocrystalline silicon solar cell technology is promoting the research and development of alternative photovoltaic materials. Copper-arsenic-sulfide (CAS) compounds are still rather unexplored in the literature, yet they have been regarded as promising candidates for use as p-type absorber in solar cells, owing to their broad raw material availability, suitable bandgap and high absorption coefficient. Here, a comprehensive study is presented on the structural and optoelectronic properties of CAS thin-films deposited via radio-frequency magnetron co-sputtering, using a commercial Cu target together with a Cu-As-S target with material obtained from local resources, specifically from mines in the Portuguese region of the Iberian Pyrite Belt. Raman and X-ray diffraction analysis confirm that the use of two targets results in films with pronounced stoichiometry gradients, suggesting a transition from amorphous CAS compounds to crystalline djurleite (Cu31S16), with the increasing proximity to the Cu target. Resistivity values from 4.7 mΩ·cm to 17.4 Ω·cm are obtained, being the lowest resistive films, those with pronounced sub-bandgap free-carrier absorption. The bandgap values range from 2.20 to 2.65 eV, indicating promising application as wide-bandgap semiconductors in third-generation (e.g., multi-junction) photovoltaic devices.

9.
Biosensors (Basel) ; 12(4)2022 Mar 28.
Artículo en Inglés | MEDLINE | ID: mdl-35448261

RESUMEN

We introduce a digital microfluidics (DMF) platform specifically designed to perform a loop-mediated isothermal amplification (LAMP) of DNA and applied it to a real-time amplification to monitor a cancer biomarker, c-Myc (associated to 40% of all human tumors), using fluorescence microscopy. We demonstrate the full manipulation of the sample and reagents on the DMF platform, resulting in the successful amplification of 90 pg of the target DNA (0.5 ng/µL) in less than one hour. Furthermore, we test the efficiency of an innovative mixing strategy in DMF by employing two mixing methodologies onto the DMF droplets-low frequency AC (alternating current) actuation as well as back-and-forth droplet motion-which allows for improved fluorescence readouts. Fluorophore bleaching effects are minimized through on-chip sample partitioning by DMF processes and sequential droplet irradiation. Finally, LAMP reactions require only 2 µL volume droplets, which represents a 10-fold volume reduction in comparison to benchtop LAMP.


Asunto(s)
Microfluídica , Neoplasias , Biomarcadores de Tumor , ADN , Colorantes Fluorescentes , Humanos , Microfluídica/métodos , Neoplasias/diagnóstico , Técnicas de Amplificación de Ácido Nucleico/métodos , Análisis de Secuencia por Matrices de Oligonucleótidos
10.
J Mater Chem B ; 9(36): 7516-7529, 2021 09 22.
Artículo en Inglés | MEDLINE | ID: mdl-34551048

RESUMEN

The development of robust and sensitive point-of-care testing platforms is necessary to improve patient care and outcomes. Surface-enhanced Raman scattering (SERS)-based immunosensors are especially suited for this purpose. Here, we present a highly sensitive and selective SERS immunoassay, demonstrating for example the detection of horseradish peroxidase (HRP), in a sandwich format. The strength of our biosensor lies in merging: (i) SERS-immunotags based on gold nanostars, allowing exceptional intense SERS from attached Raman probes, covalent attachment of anti-HRP antibodies by a simple chemical method providing exceptional antigen binding activity; (ii) the ease of preparation of the capture platform from a regenerated cellulose-based hydrogel, a transparent material, ideal for microfluidics applications, with low background fluorescence and Raman signal, particularly suited for preserving high activity of the covalently bound anti-HRP antibodies. The sandwich complexes formed were characterised by atomic force microscopy, and by scanning electron microscopy coupled with electron diffraction spectroscopy; and (iii) the robustness of the simple Classical Least Squares method for SERS data analysis, resulting in superior discrimination of SERS signals from the background and much better data fitting, compared to the commonly used peak integral method. Our SERS immunoassay greatly improves the detection limits of traditional enzyme-linked immunosorbent assay approaches, and its performance is better or comparable to those of existing SERS-based immunosensors. Our approach successfully overcomes the main challenges of application at point-of-care, including increasing reproducibility, sensitivity, and specificity, associated with an environmentally friendly and robust design. Also, the proposed design withstands several cycles of regeneration, a feature absent in paper-SERS immunoassays and this opens the way for sensitive multiplexing applications on a microfluidic platform.


Asunto(s)
Celulosa/química , Oro/química , Peroxidasa de Rábano Silvestre/análisis , Hidrogeles/química , Inmunoensayo/métodos , Nanopartículas del Metal/química , Peroxidasa de Rábano Silvestre/inmunología , Límite de Detección , Sistemas de Atención de Punto , Reciclaje , Reproducibilidad de los Resultados , Espectrometría Raman
11.
Nanomaterials (Basel) ; 11(7)2021 Jun 24.
Artículo en Inglés | MEDLINE | ID: mdl-34202858

RESUMEN

The pursuit of ever-more efficient, reliable, and affordable solar cells has pushed the development of nano/micro-technological solutions capable of boosting photovoltaic (PV) performance without significantly increasing costs. One of the most relevant solutions is based on light management via photonic wavelength-sized structures, as these enable pronounced efficiency improvements by reducing reflection and by trapping the light inside the devices. Furthermore, optimized microstructured coatings allow self-cleaning functionality via effective water repulsion, which reduces the accumulation of dust and particles that cause shading. Nevertheless, when it comes to market deployment, nano/micro-patterning strategies can only find application in the PV industry if their integration does not require high additional costs or delays in high-throughput solar cell manufacturing. As such, colloidal lithography (CL) is considered the preferential structuring method for PV, as it is an inexpensive and highly scalable soft-patterning technique allowing nanoscopic precision over indefinitely large areas. Tuning specific parameters, such as the size of colloids, shape, monodispersity, and final arrangement, CL enables the production of various templates/masks for different purposes and applications. This review intends to compile several recent high-profile works on this subject and how they can influence the future of solar electricity.

12.
Materials (Basel) ; 14(9)2021 May 04.
Artículo en Inglés | MEDLINE | ID: mdl-34064309

RESUMEN

The degradation of organic pollutants in wastewaters assisted by oxide semiconductor nanostructures has been the focus of many research groups over the last decades, along with the synthesis of these nanomaterials by simple, eco-friendly, fast, and cost-effective processes. In this work, porous zinc oxide (ZnO) nanostructures were successfully synthesized via a microwave hydrothermal process. A layered zinc hydroxide carbonate (LZHC) precursor was obtained after 15 min of synthesis and submitted to different calcination temperatures to convert it into porous ZnO nanostructures. The influence of the calcination temperature (300, 500, and 700 °C) on the morphological, structural, and optical properties of the ZnO nanostructureswas investigated. All ZnO samples were tested as photocatalysts in the degradation of rhodamine B (RhB) under UV irradiation and natural sunlight. All samples showed enhanced photocatalytic activity under both light sources, with RhB being practically degraded within 60 min in both situations. The porous ZnO obtained at 700 °C showed the greatest photocatalytic activity due to its high crystallinity, with a degradation rate of 0.091 and 0.084 min-1 for UV light and sunlight, respectively. These results are a very important step towards the use of oxide semiconductors in the degradation of water pollutants mediated by natural sunlight.

13.
Nanomaterials (Basel) ; 10(10)2020 Oct 14.
Artículo en Inglés | MEDLINE | ID: mdl-33066658

RESUMEN

Due to its properties, paper represents an alternative to perform point-of-care tests for colorimetric determination of glucose levels, providing simple, rapid, and inexpensive means of diagnosis. In this work, we report the development of a novel, rapid, disposable, inexpensive, enzyme-free, and colorimetric paper-based assay for glucose level determination. This sensing strategy is based on the synthesis of gold nanoparticles (AuNPs) by reduction of a gold salt precursor, in which glucose acts simultaneously as reducing and capping agent. This leads to a direct measurement of glucose without any enzymes or depending on the detection of intermediate products as in conventional enzymatic colorimetric methods. Firstly, we modelled the synthesis reaction of AuNPs to determine the optical, morphological, and kinetic properties and their manipulation for glucose sensing, by determining the influence of each of the reaction precursors towards the produced AuNPs, providing a guide for the manipulation of nucleation and growth. The adaptation of this synthesis into the developed paper platform was tested and calibrated using different standard solutions with physiological concentrations of glucose. The response of the colorimetric signals obtained with this paper-based platform showed a linear behavior until 20 mM, required for glycemic control in diabetes, using the Red × Value/Grey feature combination as a calibration metric, to describe the variations in color intensity and hue in the spot test zone. The colorimetric sensor revealed a detection limit of 0.65 mM, depending on calibration metric and sensitivity of 0.013 AU/mM for a linear sensitivity range from 1.25 to 20 mM, with high specificity for the determination of glucose in complex standards with other common reducing interferents and human serum.

14.
Sensors (Basel) ; 20(16)2020 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-32784603

RESUMEN

Electronic skin (e-skin), which is an electronic surrogate of human skin, aims to recreate the multifunctionality of skin by using sensing units to detect multiple stimuli, while keeping key features of skin such as low thickness, stretchability, flexibility, and conformability. One of the most important stimuli to be detected is pressure due to its relevance in a plethora of applications, from health monitoring to functional prosthesis, robotics, and human-machine-interfaces (HMI). The performance of these e-skin pressure sensors is tailored, typically through micro-structuring techniques (such as photolithography, unconventional molds, incorporation of naturally micro-structured materials, laser engraving, amongst others) to achieve high sensitivities (commonly above 1 kPa-1), which is mostly relevant for health monitoring applications, or to extend the linearity of the behavior over a larger pressure range (from few Pa to 100 kPa), an important feature for functional prosthesis. Hence, this review intends to give a generalized view over the most relevant highlights in the development and micro-structuring of e-skin pressure sensors, while contributing to update the field with the most recent research. A special emphasis is devoted to the most employed pressure transduction mechanisms, namely capacitance, piezoelectricity, piezoresistivity, and triboelectricity, as well as to materials and novel techniques more recently explored to innovate the field and bring it a step closer to general adoption by society.


Asunto(s)
Miembros Artificiales , Robótica , Dispositivos Electrónicos Vestibles , Electrónica , Humanos , Presión
15.
ACS Appl Mater Interfaces ; 12(16): 18421-18430, 2020 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-32195567

RESUMEN

The current trend for smart, self-sustainable, and multifunctional technology demands for the development of energy harvesters based on widely available and environmentally friendly materials. In this context, ZnSnO3 nanostructures show promising potential because of their high polarization, which can be explored in piezoelectric devices. Nevertheless, a pure phase of ZnSnO3 is hard to achieve because of its metastability, and obtaining it in the form of nanowires is even more challenging. Although some groups have already reported the mixing of ZnSnO3 nanostructures with polydimethylsiloxane (PDMS) to produce a nanogenerator, the resultant polymeric film is usually flat and does not take advantage of an enhanced piezoelectric contribution achieved through its microstructuration. Herein, a microstructured composite of nanowires synthesized by a seed-layer free hydrothermal route mixed with PDMS (ZnSnO3@PDMS) is proposed to produce nanogenerators. PFM measurements show a clear enhancement of d33 for single ZnSnO3 versus ZnO nanowires (23 ± 4 pm/V vs 9 ± 2 pm/V). The microstructuration introduced herein results in an enhancement of the piezoelectric effect of the ZnSnO3 nanowires, enabling nanogenerators with an output voltage, current, and instantaneous power density of 120 V, 13 µA, and 230 µW·cm-2, respectively. Even using an active area smaller than 1 cm2, the performance of this nanogenerator enables lighting up multiple LEDs and other small electronic devices, thus proving great potential for wearables and portable electronics.

16.
Sensors (Basel) ; 20(6)2020 Mar 14.
Artículo en Inglés | MEDLINE | ID: mdl-32183359

RESUMEN

Microfluidic (MF) advancements have been leveraged toward the development of state-of-the-art platforms for molecular diagnostics, where isothermal amplification schemes allow for further simplification of DNA detection and quantification protocols. The MF integration with loop-mediated isothermal amplification (LAMP) is today the focus of a new generation of chip-based devices for molecular detection, aiming at fast and automated nucleic acid analysis. Here, we combined MF with droplet digital LAMP (ddLAMP) on an all-in-one device that allows for droplet generation, target amplification, and absolute quantification. This multilayer 3D chip was developed in less than 30 minutes by using a low-cost and extremely adaptable production process that exploits direct laser writing technology in "Shrinky-dinks" polystyrene sheets. ddLAMP and target quantification were performed directly on-chip, showing a high correlation between target concentration and positive droplet score. We validated this integrated chip via the amplification of targets ranging from five to 500,000 copies/reaction. Furthermore, on-chip amplification was performed in a 10 µL volume, attaining a limit of detection of five copies/µL under 60 min. This technology was applied to quantify a cancer biomarker, c-MYC, but it can be further extended to any other disease biomarker.


Asunto(s)
Biomarcadores de Tumor/aislamiento & purificación , Técnicas Biosensibles , ADN de Neoplasias/aislamiento & purificación , Neoplasias/diagnóstico , Biomarcadores de Tumor/genética , ADN de Neoplasias/genética , Humanos , Dispositivos Laboratorio en un Chip , Límite de Detección , Microfluídica/métodos , Técnicas de Diagnóstico Molecular/métodos , Neoplasias/genética , Neoplasias/patología , Técnicas de Amplificación de Ácido Nucleico/métodos , Patología Molecular/métodos
17.
Sci Rep ; 9(1): 17922, 2019 11 29.
Artículo en Inglés | MEDLINE | ID: mdl-31784619

RESUMEN

Throughout the last decade, the expansion of food testing has been gradually moving towards ordinary high throughput screening methods performed on-site. The demand for point-of-care testing, able to distinguish molecular signatures with high accuracy, sensitivity and specificity has been significantly increasing. This new requirement relies on the on-site detection and monitorization of molecular signatures suitable for the surveillance of food production and processing. The widespread use of antibiotics has contributed to disease control of livestock but has also created problems for the dairy industry and consumers. Its therapeutic and subtherapeutic use has increased the risk of contamination in milk in enough concentrations to cause economic losses to the dairy industry and have a health impact in highly sensitive individuals. This study focuses on the development of a simple Surface-Enhanced Raman Spectroscopy (SERS) method for fast high throughput screening of tetracycline (TET) in milk. For this, we integrate a paper-based low-cost, fully recyclable and highly stable SERS platform, with a minimal sample preparation protocol. A two-microliter sample of milk solutions spiked with TET (from 0.01 to 1000 ppm) is dried on a silver nanoparticle coated cardboard substrate and measured via a Raman spectrophotometer. The SERS substrate showed to be extremely stable with a shelf life of several months. A global spectrum principal component analysis approach was used to test all the detected vibrational modes and their correlation with TET concentration. Peak intensity ratios (455 cm-1/1280 cm-1 and 874 cm-1/1397 cm-1) were found to be correlated with TET concentrations in milk, achieving a sensitivity as low as 0.1 ppm. Results indicate that this SERS method combined with portable Raman spectrometer is a potential tool that can be used on-site for the monitoring of TET residues and other antibiotics.


Asunto(s)
Análisis de los Alimentos/métodos , Leche/química , Espectrometría Raman/métodos , Tetraciclina/análisis , Animales , Análisis de los Alimentos/normas , Leche/normas , Sensibilidad y Especificidad , Espectrometría Raman/normas
18.
Nanomaterials (Basel) ; 9(11)2019 Nov 04.
Artículo en Inglés | MEDLINE | ID: mdl-31689919

RESUMEN

Immunoassays using Surface-Enhanced Raman Spectroscopy are especially interesting on account not only of their increased sensitivity, but also due to its easy translation to point-of-care formats. The bases for these assays are bioconjugates of polyclonal antibodies and anisotropic gold nanoparticles functionalized with a Raman reporter. These bioconjugates, once loaded with the antigen analyte, can react on a sandwich format with the same antibodies immobilized on a surface. This surface can then be used for detection, on a microfluidics or immunochromatographic platform. Here, we have assembled bioconjugates of gold nanostars functionalized with 4-mercaptobenzoic acid, and anti-horseradish peroxidase antibodies. The assembly was by simple incubation, and agarose gel electrophoresis determined a high gold nanostar to antibody binding constant. The functionality of the bioconjugates is easy to determine since the respective antigen presents peroxidase enzymatic activity. Furthermore, the chosen antibody is a generic immunoglobulin G (IgG) antibody, opening the application of these principles to other antibody-antigen systems. Surface-Enhanced Raman Spectroscopy analysis of these bioconjugates indicated antigen detection down to 50 µU of peroxidase activity. All steps of conjugation were fully characterized by ultraviolet-visible spectroscopy, dynamic light scattering, ζ -Potential, scanning electron microscopy, and agarose gel electrophoresis. Based on the latter technique, a proof-of-concept was established for the proposed immunoassay.

19.
ACS Sens ; 4(8): 2073-2083, 2019 08 23.
Artículo en Inglés | MEDLINE | ID: mdl-31327232

RESUMEN

Breast cancer accounts for 11.6% of all cancer cases in both genders. Even though several diagnostic techniques have been developed, the mostly used are invasive, complex, time-consuming, and cannot guarantee an early diagnosis, significantly constraining the tumor treatment success rate. Exosomes are extracellular vesicles that carry biomolecules from tissues to the peripheral circulation, representing an emerging noninvasive source of markers for early cancer diagnosis. Current techniques for exosomes analysis are frequently complex, time-consuming, and expensive. Raman spectroscopy interest has risen lately, because of its nondestructive analysis and little to no sample preparation, while having very low analyte concentration/volume, because of surface enhancement signal (SERS) possibility. However, active SERS substrates are needed, and commercially available substrates come with a high cost and low shelf life. In this work, composites of commercial nata de coco to produce bacterial nanocellulose and in-situ-synthesized silver nanoparticles are tested as SERS substrates, with a low cost and green approach. Enhancement factors from 104 to 105 were obtained, detecting Rhodamine 6G (R6G) concentrations as low as 10-11 M. Exosome samples coming from MCF-10A (nontumorigenic breast epithelium) and MDA-MB-231 (breast cancer) cell cultures were tested on the synthesized substrates, and the obtained Raman spectra were subjected to statistical principal component analysis (PCA). Combining PCA with Raman intravariability and intervariability in exosomal samples, data grouping with 95% confidence was possible, serving as a low-cost, green, and label-free diagnosis method, with promising applicability in clinical settings.


Asunto(s)
Técnicas Biosensibles , Neoplasias de la Mama/diagnóstico , Técnicas Electroquímicas , Exosomas/química , Nanotecnología , Femenino , Humanos , Células Tumorales Cultivadas
20.
Sensors (Basel) ; 19(4)2019 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-30795531

RESUMEN

Electronic skin (e-skin) is pursued as a key component in robotics and prosthesis to confer them sensing properties that mimic human skin. For pressure monitoring, a great emphasis on piezoresistive sensors was registered due to the simplicity of sensor design and readout mechanism. For higher sensitivity, films composing these sensors may be micro-structured, usually by expensive photolithography techniques or low-cost and low-customizable molds. Sensors commonly present different sensitivities in different pressure ranges, which should be avoided in robotics and prosthesis applications. The combination of pressure sensing and temperature is also relevant for the field and has room for improvement. This work proposes an alternative approach for film micro-structuration based on the production of highly customizable and low-cost molds through laser engraving. These bimodal e-skin piezoresistive and temperature sensors could achieve a stable sensitivity of -6.4 × 10-3 kPa-1 from 1.6 kPa to 100 kPa, with a very robust and reproducible performance over 27,500 cycles of objects grasping and releasing and an exceptionally high temperature coefficient of resistance (TCR) of 8.3%/°C. These results point toward the versatility and high benefit/cost ratio of the laser engraving technique to produce sensors with a suitable performance for robotics and functional prosthesis.


Asunto(s)
Miembros Artificiales , Técnicas Biosensibles/métodos , Robótica/métodos , Dispositivos Electrónicos Vestibles , Humanos , Rayos Láser , Presión , Implantación de Prótesis/métodos , Temperatura
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA