Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Acta Chir Belg ; 124(2): 91-98, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36905354

RESUMEN

INTRODUCTION: Minimally invasive ventral mesh rectopexy is considered the standard of care in the surgical management of rectal prolapse syndromes in fit patients. We aimed to investigate the outcomes after robotic ventral mesh rectopexy (RVR) and compare them with our laparoscopic series (LVR). Additionally, we report the learning curve of RVR. As the financial aspect for the use of a robotic platform remains an important obstacle to allow generalized adoption, cost-effectiveness was also evaluated. PATIENTS AND METHODS: A prospectively maintained data set including 149 consecutive patients who underwent a minimally invasive ventral rectopexy between December 2015 and April 2021 was reviewed. The results after a median follow-up of 32 months were analyzed. Additionally, a thorough assessment of the economic aspect was performed. RESULTS: On a total of 149 consecutive patients 72 underwent a LVR and 77 underwent a RVR. Median operative time was comparable for both groups (98 min (RVR) vs. 89 min (LVR); p = 0.16). Learning curve showed that an experienced colorectal surgeon required approximately 22 cases in stabilizing the operative time for RVR. Overall functional results were similar in both groups. There were no conversions or mortality. There was, however, a significant difference (p < 0.01) in hospital stay in favor of the robotic group (1 day vs. 2 days). The overall cost of RVR was higher than LVR. CONCLUSIONS: This retrospective study shows that RVR is a safe and feasible alternative for LVR. With specific adjustments in surgical technique and robotic materials, we developed a cost-effective way of performing RVR.


Asunto(s)
Laparoscopía , Prolapso Rectal , Procedimientos Quirúrgicos Robotizados , Humanos , Prolapso Rectal/cirugía , Prolapso Rectal/etiología , Procedimientos Quirúrgicos Robotizados/métodos , Estudios Retrospectivos , Mallas Quirúrgicas , Resultado del Tratamiento , Laparoscopía/métodos , Recto/cirugía
2.
Langenbecks Arch Surg ; 407(5): 2177-2186, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35612661

RESUMEN

PURPOSE: Robotic retromuscular abdominal wall repair (RAWR) for ventral hernias can be performed transabdominal or extraperitoneal by using an enhanced view totally extraperitoneal repair (eTEP). For defects in the meso- or epigastric region, an inverted approach can be used, starting the development of the totally extraperitoneal plane in the suprapubic region and progressing in a caudal-to-cranial direction (inverted TEP, iTEP). The aim of the study is to present the surgical technique and to report the short-term outcomes. METHODS: A retrospective analysis of a prospectively maintained database was performed, including patients who underwent a robotic RAWR using the iTEP approach between December 2019 and January 2022. The surgical technique was described, and patients' characteristics and intra- and postoperative parameters were studied and compared to the TARUP technique (robotic transabdominal retromuscular umbilical prosthetic hernia repair). RESULTS: Thirty-four patients were treated with an iTEP approach, and 14 patients underwent a TARUP procedure. The median length of stay was 1 day (range 1-3), and there were no intraoperative complications in both groups. One patient (3%) required reoperation after an iTEP approach for a small bowel internal herniation due to a rupture of the posterior rectus sheath. There were no recurrences or mortality with a median follow-up of 15 months (range 3-29) in the iTEP group, compared to 35 months (range 29-37) in the TARUP group. CONCLUSION: For defects in the upper abdominal region, a robotic RAWR with an iTEP approach appears to be safe and feasible. Long-term follow-up is needed to evaluate the late recurrence rate.


Asunto(s)
Pared Abdominal , Hernia Ventral , Laparoscopía , Procedimientos Quirúrgicos Robotizados , Pared Abdominal/cirugía , Hernia Ventral/cirugía , Herniorrafia/efectos adversos , Humanos , Laparoscopía/métodos , Estudios Retrospectivos , Procedimientos Quirúrgicos Robotizados/métodos , Mallas Quirúrgicas
3.
Acta Chir Belg ; 119(3): 176-181, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29284350

RESUMEN

BACKGROUND: Mesh migration and erosion into adjacent viscera is a rare complication after laparoscopic inguinal hernia repair. We present a minimally invasive treatment of an asymptomatic case of mesh erosion into the caecum after total extraperitoneal inguinal hernia repair, including an overview of the relevant recent literature. METHODS: A male patient underwent a laparoscopic inguinal hernia repair at the age of 42. Two years after this procedure, a screening colonoscopy revealed erosion of the mesh into the caecum. A laparoscopy was performed with partial resection of the mesh and minimal resection of the involved colon. Results of a systematic review of English PubMed articles on mesh migration and erosion after inguinal hernia repair is presented. RESULTS: We report a first-time minimally invasive treatment of mesh erosion into the colon. A laparoscopic approach is feasible and provides an excellent exposure. Partial removal of the mesh is suggested in uncomplicated cases to avoid complications associated with complete mesh removal.


Asunto(s)
Ciego/lesiones , Migración de Cuerpo Extraño/cirugía , Hernia Inguinal/cirugía , Procedimientos Quirúrgicos Mínimamente Invasivos , Polipropilenos , Complicaciones Posoperatorias/cirugía , Mallas Quirúrgicas/efectos adversos , Adulto , Ciego/diagnóstico por imagen , Ciego/cirugía , Colonoscopía , Remoción de Dispositivos , Migración de Cuerpo Extraño/diagnóstico por imagen , Humanos , Laparoscopía , Masculino , Complicaciones Posoperatorias/diagnóstico por imagen , Tomografía Computarizada por Rayos X
4.
Obes Surg ; 21(12): 1822-7, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-21656166

RESUMEN

Reported incidence of small bowel obstruction (SBO) after laparoscopic Roux-en-Y gastric bypass varies between 1.5% and 3.5%. It has been suggested that the antecolic antegastric laparoscopic Roux-en-Y gastric bypass (AA-LRYGB) is associated with a low incidence of internal herniation (IH). Therefore we routinely did not close mesenteric defects. The records of 652 consecutive patients undergoing primary AA-LRYGB from January 2003 to December 2009 in a single institution were retrospectively reviewed to determine the incidence, etiology, clinical symptoms, radiologic diagnostic accuracy and operative outcomes of SBO. Of the 652 patients, 63 (9.6%) developed SBO. The majority (6.9%, 45 patients) had a SBO due to IH. In 41 (91%) cases, the IH was at the jejunojejunostomy (JJ), four cases had an IH at Petersen's space. Adhesions and ventral hernia were found in 14 (2.1%) and four (0.6%) cases, respectively. Twenty-nine out of 63 cases had negative computed tomography (CT) findings and IH was diagnosed on CT in only 33% (14/45) of patients with IH. All patients underwent diagnostic laparoscopy. No bowel resections had to be performed. In contrast to previous reports, a high incidence of SBO with a high rate of IH at the JJ site was found in our series. Accuracy of CT is low and diagnostic laparoscopy is mandatory when SBO is suspected. Since 2010 we have started closing the JJ site, and data on SBO are collected prospectively. We believe that closing of the mesenteric defects is a mandatory step, even in an AA-LRYGB.


Asunto(s)
Derivación Gástrica/efectos adversos , Derivación Gástrica/métodos , Obstrucción Intestinal/etiología , Enfermedades del Yeyuno/etiología , Laparoscopía , Adulto , Femenino , Humanos , Masculino , Mesenterio , Estudios Retrospectivos , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...