Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 67
Filtrar
1.
J Endocrinol Invest ; 47(1): 223-234, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37354248

RESUMEN

PURPOSE: Brain metastases rarely complicate the natural history of patients with adrenocortical carcinoma (ACC). No information is available regarding the life expectancy and efficacy of treatments in ACC patients with brain involvement. METHODS: A pooled analysis was performed by searching on PubMed and using the keywords: "brain metastases in adrenocortical carcinoma", and "leptomeningeal metastases in adrenocortical carcinoma". Four patients diagnosed at Spedali Civili Hospital in Brescia were added to the analysis. Data concerning demographic, disease characteristics, adopted treatments and patient prognosis were collected. RESULTS: A total of 27 patients (18 adults and 9 children) were included in this study, 22 of them had an adequate follow-up. Brain metastases occurred late in the natural history of adult patients but not in that of children. Surgery plus/minus radiation therapy was the treatment of choice. Adult patients with brain metastases had a poor prognosis with a median progression-free survival (PFS) and overall survival (OS) of 2 and 7 months, respectively. Median PFS and OS were not attained in children. CONCLUSION: Brain metastases in ACC patients are rare and are associated with poor prognosis, particularly in adults. Surgery plus/minus radiotherapy is the only therapeutic approach that can offer patients a chance to obtain durable local disease control.


Asunto(s)
Neoplasias de la Corteza Suprarrenal , Carcinoma Corticosuprarrenal , Neoplasias Encefálicas , Adulto , Niño , Humanos , Carcinoma Corticosuprarrenal/patología , Resultado del Tratamiento , Pronóstico , Neoplasias Encefálicas/terapia , Neoplasias de la Corteza Suprarrenal/patología , Estudios Retrospectivos
2.
J Neuroinflammation ; 20(1): 300, 2023 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-38102698

RESUMEN

Graft-versus-host disease (GVHD) is a serious complication of otherwise curative allogeneic haematopoietic stem cell transplants. Chronic GVHD induces pathological changes in peripheral organs as well as the brain and is a frequent cause of late morbidity and death after bone-marrow transplantation. In the periphery, bone-marrow-derived macrophages are key drivers of pathology, but recent evidence suggests that these cells also infiltrate into cGVHD-affected brains. Microglia are also persistently activated in the cGVHD-affected brain. To understand the involvement of these myeloid cell populations in the development and/or progression of cGVHD pathology, we here utilized the blood-brain-barrier permeable colony stimulating factor-1 receptor (CSF-1R) inhibitor PLX3397 (pexidartinib) at varying doses to pharmacologically deplete both cell types. We demonstrate that PLX3397 treatment during the development of cGVHD (i.e., 30 days post-transplant) improves disease symptoms, reducing both the clinical scores and histopathology of multiple cGVHD target organs, including the sequestration of T cells in cGVHD-affected skin tissue. Cognitive impairments associated with cGVHD and neuroinflammation were also attenuated by PLX3397 treatment. PLX3397 treatment prior to the onset of cGVHD (i.e., immediately post-transplant) did not change in clinical scores or histopathology. Overall, our data demonstrate significant benefits of using PLX3397 for the treatment of cGVHD and associated organ pathologies in both the periphery and brain, highlighting the therapeutic potential of pexidartinib for this condition.


Asunto(s)
Enfermedad Injerto contra Huésped , Trasplante de Células Madre Hematopoyéticas , Ratones , Animales , Trasplante de Médula Ósea , Enfermedad Injerto contra Huésped/tratamiento farmacológico , Enfermedad Injerto contra Huésped/patología , Proteínas Tirosina Quinasas Receptoras , Receptores del Factor Estimulante de Colonias , Encéfalo/patología , Enfermedad Crónica
3.
Eur J Paediatr Dent ; 24(3): 211-215, 2023 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-37668460

RESUMEN

AIM: To evaluate the buccal alveolar bone changes and the upper first molar displacement in subjects treated with conventional rapid maxillary expansion (RME), Ni-Ti leaf springs expander (Leaf Expander) and Tooth-Bone-borne Expander (Hybrid Expander) using CBCT scans. METHODS: The sample consisted of 52 children treated with RME (n=18), Leaf Expander (n= 17) and Hybrid Expander (n= 17). CBCTs were taken before and after maxillary expansion and the Horos software was used for the analysis. Descriptive statistics and paired t-test were used to assess changes between the pre-treatment and post-treatment measurements. ANOVA test and Tukey's post hoc test with Bonferroni correction was used for between groups comparison. CONCLUSION: The Hybrid Expander during preadolescence showed few advantages over the use of tooth-anchored expanders. An expansion approach with mini-screws is not preferable during early mixed dentition to a conventional approach. The differences in dental tipping values were clinically insignificant and the reduction in cortical bone thickness remained less than 1 mm. When possible, the use of second primary molars as anchorage should be preferred.


Asunto(s)
Técnica de Expansión Palatina , Tomografía Computarizada de Haz Cónico Espiral , Niño , Humanos , Diente Molar/diagnóstico por imagen , Dentición Mixta
4.
Eur J Paediatr Dent ; 24(3): 180 - 187, 2023 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-37337957

RESUMEN

AIM: The aim of this study was to assess the skeletal and dento-alveolar changes produced by a customised eruption guidance appliance (EGA) and a preformed EGA in subjects presenting a skeletal class II pattern during early mixed dentition and to evaluate the differences between the two devices. METHODS: All subjects included in the study were randomly selected from the record's archive according to the following inclusion criteria: (1) patients presenting upper central incisor and first permanent molars fully erupted; (2) early mixed dentition with age between 7 to 9 years old; (3) Angle class I or class II malocclusion; (4) increased overjet > 4 mm;(5) deep bite with at least 2/3 overlapping of the incisors; (6) no previous orthodontic treatment apart from maxillary expansion treatment. All children belonging to the case group received treatment with a 3D printed EGA whereas the other patients belonging to the control group were treated with preformed EGA. Records consisted in digital dental models and lateral cephalogram at the beginning (T0) and after 1 year of treatment (T1). Data collected on the digital models included the dentoalveolar changes in overbite, overjet, sagittal molar relationship, and dental crowding. Cephalometric tracings were computed by a single blinded observer using Dolphin Imaging software. Statistical analysis was performed with SPSS (version 25.00; IBM Corp, Armonk, NY). Comparison regarding the cephalometric changes between T1-T2 was carried out with paired t-test. Difference in distribution regarding sagittal molar and canine relationship and anterior crowding between groups at T1 and T2 has been computed with chi-square test. The independent sample t-test was used to perform the between group comparison. CONCLUSION: In the short time, both the appliances showed to be effective in correcting class II malocclusion, anterior crowding, overjet and overbite. Custom-made appliance demonstrated to be significantly more effective in correcting anterior crowding, the dento-skeletal vertical relation and position of permanent incisor compared to the preformed appliance. Adopting a customised device, effects due to an average prescription appliance used to a specific patient can be reduced, resulting in more predictable results.


Asunto(s)
Maloclusión Clase II de Angle , Maloclusión , Sobremordida , Humanos , Sobremordida/terapia , Dentición Mixta , Maloclusión/terapia , Maloclusión Clase II de Angle/diagnóstico por imagen , Maloclusión Clase II de Angle/terapia , Cefalometría/métodos , Mandíbula
5.
ESMO Open ; 7(2): 100422, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35272132

RESUMEN

BACKGROUND: Adrenocortical carcinoma (ACC) is a rare and aggressive malignancy with a poor prognosis. No efficacious treatment options are currently available for patients with advanced metastatic disease with disease progression to standard etoposide, doxorubicin, cisplatin and mitotane (EDP-M) therapy. We assessed the activity and tolerability of cabazitaxel as a second/third-line approach in metastatic ACC. PATIENTS AND METHODS: Patients included in this single-center, phase II study (ClinicalTrials.gov identifier NCT03257891) had disease progression to a cisplatin-containing regimen (such as EDP) plus mitotane, plus/minus a further chemotherapy line. Cabazitaxel was administered intravenously at 25 mg/m2 on day 1 of a 21-day cycle, for a maximum of six cycles. The primary endpoint was a disease control rate after 4 months. RESULTS: From March 2018 to September 2019, 25 eligible patients were enrolled. A disease control rate after 4 months was obtained in six patients (24%). No patients attained a disease response according to RECIST 1.1, 9 patients (36%) had stable disease and 16 patients (64%) progressive disease. Median progression-free survival and overall survival were 1.5 months (range 0.3-7 months) and 6 months (range 1-22.2 months), respectively. Cabazitaxel therapy was well tolerated and only three (12%) patients developed grade 3 toxicity which were nausea in one patient (4%) and anemia in two patients (8%). CONCLUSIONS: Cabazitaxel has a manageable toxicity profile but is poorly active as second/third-line treatment in advanced ACC patients. These results do not support further evaluation of cabazitaxel in this setting.


Asunto(s)
Neoplasias de la Corteza Suprarrenal , Carcinoma Corticosuprarrenal , Neoplasias de la Corteza Suprarrenal/tratamiento farmacológico , Neoplasias de la Corteza Suprarrenal/patología , Carcinoma Corticosuprarrenal/tratamiento farmacológico , Carcinoma Corticosuprarrenal/etiología , Carcinoma Corticosuprarrenal/patología , Protocolos de Quimioterapia Combinada Antineoplásica/efectos adversos , Cisplatino/efectos adversos , Progresión de la Enfermedad , Humanos , Mitotano/efectos adversos , Taxoides
6.
iScience ; 24(11): 103326, 2021 Nov 19.
Artículo en Inglés | MEDLINE | ID: mdl-34805788

RESUMEN

Langerhans cells (LC) are skin-resident antigen-presenting cells that regulate immune responses to epithelial microorganisms. Human papillomavirus (HPV) infection can promote malignant epithelial transformation. As LCs are considered important for controlling HPV infection, we compared the transcriptome of murine LCs from skin transformed by K14E7 oncoprotein and from healthy skin. We identified transcriptome heterogeneity at the single cell level amongst LCs in normal skin, associated with ontogeny, cell cycle, and maturation. We identified a balanced co-existence of immune-stimulatory and immune-inhibitory LC cell states in normal skin that was significantly disturbed in HPV16 E7-transformed skin. Hyperplastic skin was depleted of immune-stimulatory LCs and enriched for LCs with an immune-inhibitory gene signature, and LC-keratinocyte crosstalk was dysregulated. We identified reduced expression of interleukin (IL)-34, a critical molecule for LC homeostasis. Enrichment of an immune-inhibitory LC gene signature and reduced levels of epithelial IL-34 were also found in human HPV-associated cervical epithelial cancers.

7.
ChemSusChem ; 13(21): 5722-5730, 2020 Nov 06.
Artículo en Inglés | MEDLINE | ID: mdl-32881341

RESUMEN

For several years, scientists have been trying to understand the mechanisms that reduce the long-term stability of perovskite solar cells. In this work, we examined the effect of water and photon flux on the stability of CH3 NH3 PbI3 perovskite films and solar cells using in situ near-ambient pressure X-ray photoelectron spectroscopy (NAP-XPS), field emission scanning electron microscopy (FESEM), and current density-voltage (J-V) characterization. The used amount of water vapor (up to 1 mbar) had a negligible impact on the perovskite film. The higher the photon flux, the more prominent were the changes in the NAP-XPS and FESEM data; also, a faster decline in power conversion efficiency (PCE) and a more substantial hysteresis in the J-V characteristics were observed. Based on our results, it can be concluded that the PCE decrease originates from the creation of Frenkel pair defects in the perovskite film under illumination. The stronger the illumination, the higher the number of Frenkel defects, leading to a faster PCE decline and more substantial hysteresis in the J-V sweeps.

8.
10.
Injury ; 49 Suppl 4: S43-S47, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30526949

RESUMEN

Nonunion of the humeral shaft occurs in 2%-10% of nonsurgically treated fractures and in up to 15% of fractures treated by primary open reduction and internal fixation. Gunshot humerus shaft fractures are a frequent type of injury; the degree of comminution and bone loss, as well as soft tissue disruption may influence the healing process, causing major sequelae with loss of function. Here we describe a 30 years old midshaft nonunion of the humerus, that occurred in a young woman after a gunshot. She was initially treated with hanging cast with definitive nonunion and secondary loss of limb function. After 30 years, careful management of the non union fracture ends, locked intramedullary nailing and bone grafting harvested from the femoral canal using the Reamer Irrigator Aspirator (RIA) system led to union with recovery of limb function.


Asunto(s)
Trasplante Óseo , Curación de Fractura/fisiología , Fracturas no Consolidadas/cirugía , Fracturas del Húmero/cirugía , Recuperación de la Función/fisiología , Heridas por Arma de Fuego/cirugía , Anciano , Clavos Ortopédicos , Placas Óseas , Femenino , Estudios de Seguimiento , Fracturas no Consolidadas/fisiopatología , Humanos , Fracturas del Húmero/fisiopatología , Calidad de Vida , Factores de Tiempo , Resultado del Tratamiento , Heridas por Arma de Fuego/complicaciones , Heridas por Arma de Fuego/fisiopatología
11.
Injury ; 49 Suppl 3: S19-S25, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-30415664

RESUMEN

INTRODUCTION: Few clinical studies have analyzed the utility of distal interlocking screws in stable and unstable intertrochanteric fractures treated with intramedullary devices. We performed a prospective analysis comparing short unlocked versus short dynamic and short static distal locked intramedullary nails. MATERIALS AND METHODS: Nine level-II trauma centres were involved in the study. 240 patients over the age of 65 with a stable (AO/OTA 31-A1) or unstable intertrochanteric fracture (AO/OTA 31-A2) were prospectively investigated. The same type of nail was used in every patient. Patients were randomly divided into 3 groups according to the type of distal locking used. Intra-operative variables were examined and patients were followed clinically and radiographically at 1, 3, 6, 12 months postoperatively. All complications were recorded. RESULTS: A total of 212 patients completed 1 year of follow-up visits. In the Unlocking Group (UG) the operation time, blood loss, fluoroscopy time, total length of incision were significantly decreased compared to both the Dynamic Group (DG) and the Static Group (SG) (p < 0.05). Conversely, no reliable differences in intraoperative variables were noted between the Dynamic Group and the Static Group (p > 0.05). In terms of time of fracture union we found no differences among the three Groups (p > 0.05). Moreover, no cases of limb shortening >1 cm or varus collapse were detected in any group. The 3 Groups were similar in terms of HHS, SF-12 and Barthel index results at 1-year follow-up (p > 0.05). Finally, no significant differences were demonstrated across the three Groups in terms of major complications. CONCLUSIONS: This clinical study further confirms the hypothesis that short intramedullary nails do not need to be locked for stable and unstable intertrochanteric fractures.


Asunto(s)
Clavos Ortopédicos , Fijación Intramedular de Fracturas , Curación de Fractura/fisiología , Fracturas de Cadera/cirugía , Inestabilidad de la Articulación/cirugía , Anciano , Femenino , Fluoroscopía , Estudios de Seguimiento , Fijación Intramedular de Fracturas/instrumentación , Fijación Intramedular de Fracturas/métodos , Fracturas de Cadera/diagnóstico por imagen , Fracturas de Cadera/fisiopatología , Humanos , Inestabilidad de la Articulación/diagnóstico por imagen , Inestabilidad de la Articulación/fisiopatología , Masculino , Estudios Prospectivos , Rango del Movimiento Articular , Centros Traumatológicos , Resultado del Tratamiento
12.
Biomicrofluidics ; 11(3): 034111, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28611871

RESUMEN

Droplet microfluidic techniques can perform large numbers of single molecule and cell reactions but often require controlled, periodic flow to merge, split, and sort droplets. Here, we describe a simple method to convert aperiodic flows into periodic ones. Using an oil extraction module, we efficiently remove oil from emulsions to readjust the droplet volume fraction, velocity, and packing, producing periodic flows. The extractor acts as a universal adaptor to connect microfluidic modules that do not operate under identical flow conditions, such as droplet generators, incubators, and merger devices.

13.
Soft Matter ; 13(8): 1654-1659, 2017 Feb 22.
Artículo en Inglés | MEDLINE | ID: mdl-28138668

RESUMEN

Organic-inorganic perovskites are semiconductors used for applications in optoelectronics and photovoltaics. Micron and submicron perovskite patterns have been explored in semitransparent photovoltaic and lasing applications. In this work, we show that a polymeric medium can be used to create a patterned perovskite, by using a novel and inexpensive approach.

14.
Musculoskelet Surg ; 100(Suppl 1): 45-51, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-27900703

RESUMEN

INTRODUCTION: The treatment for humeral diaphyseal fractures is still controversial. The purpose of this study was to evaluate the clinical and radiographic outcomes of treating humeral distal third diaphyseal fractures by using external fixation technique. MATERIALS AND METHODS: We retrospectively review 65 cases of diaphyseal humeral fractures (31 type A, 23 type B and 11 type C of the AO/OTA classification) treated with external fixation (Orthofix FAD small) between 2008 and 2013. The mean follow-up was 48 months (24-72 months). There were 12 open fractures; however, no cases of concomitant vascular injury were described. The transolecranic traction was always applied to promote partial reduction through ligamentotaxis. In case of interposition of soft tissues impeding reduction, a small incision was performed allowing mobilization of bone ends. RESULTS: All fractures resulted healed at a mean of 11 weeks (range 9-13 weeks); the average time of removal of the external fixator was 88 days (range 65-95 days). At the last follow-up, the mean elbow flexion was 132.6° (Min 126°-Max 137°) and the mean elbow extension was 6.4° (Max 0°-Min 13°). The Cassebaum's index rated as excellent in 47.8 % (31 patients), good in 37 % (24 patients), fair in 9.2 % (6 patients) and poor in 6 % (4 patients). The mean DASH score at the final follow-up was 14.7 (range 0-33); 15 patients had a range score between 10 and 20, 43 had less than 10, and seven had more than 20. We observed three cases of superficial infections and two cases of acute radial nerve palsy recovered within 3 months. CONCLUSION: According to the excellent clinical results and full rate of consolidation, we state external fixation as a valid option in the treatment of distal third humeral diaphyseal fractures.


Asunto(s)
Fijadores Externos , Fracturas del Húmero/terapia , Adulto , Femenino , Estudios de Seguimiento , Curación de Fractura , Humanos , Fracturas del Húmero/clasificación , Masculino , Persona de Mediana Edad , Rango del Movimiento Articular , Estudios Retrospectivos , Resultado del Tratamiento
15.
Injury ; 47 Suppl 4: S98-S106, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-27523625

RESUMEN

We investigated whether a proximal femoral nail can be implanted without a distal locking screw in AO/OTA 31-A1 and 31-A2 pertrochanteric stable femur fractures. A multicentre, randomised study was conducted in six level-two trauma centres in our area (Puglia, Italy). A total of 333 patients received their allocated intervention (162 in the locking group [LG] and 171 in the unlocking group [UG]) and 266 patients were included in the final analysis at 1year. Our data showed no statistically significant difference between the two groups at 1-year follow-up for ability to walk, SF-36 questionnaire results, residual pain (visual analogue scale [VAS] score) and level of overall satisfaction. There were also no statistically significant differences between groups for mortality and length of hospital stay. Conversely, the UG was associated with shorter operation and fluoroscopy times, shorter surgical incision length, and less blood loss and residual thigh pain. Pertrochanteric stable fractures (31-A1, 31-A2) can be treated successfully with intramedullary nails without distal locking, reducing patient and clinical personnel radiation exposure and sanitary costs (surgery time and screws costs).


Asunto(s)
Clavos Ortopédicos , Fracturas del Fémur/cirugía , Fijación Intramedular de Fracturas , Fracturas Osteoporóticas/cirugía , Complicaciones Posoperatorias/diagnóstico por imagen , Centros Traumatológicos , Anciano , Anciano de 80 o más Años , Tornillos Óseos , Femenino , Fracturas del Fémur/diagnóstico por imagen , Fracturas del Fémur/fisiopatología , Fluoroscopía , Fijación Intramedular de Fracturas/métodos , Curación de Fractura , Humanos , Italia/epidemiología , Masculino , Tempo Operativo , Fracturas Osteoporóticas/diagnóstico por imagen , Fracturas Osteoporóticas/fisiopatología , Satisfacción del Paciente , Complicaciones Posoperatorias/fisiopatología , Complicaciones Posoperatorias/cirugía , Estudios Prospectivos , Resultado del Tratamiento
16.
Phys Chem Chem Phys ; 18(39): 27083-27089, 2016 Oct 21.
Artículo en Inglés | MEDLINE | ID: mdl-27400647

RESUMEN

A new Zn(ii) phthalocyanine (Pc) based low bandgap HTM is introduced for perovskite solar cells. Steady state and time-resolved photoluminescence (PL) measurements indicated an evenly matched hole extraction efficiency between sym-HTPcH and spiro-OMeTAD. On account of the low film quality and resulting high recombination, Zn(ii) Pc normally cannot work as an effective HTM. We adopted insulating Al2O3 for the infiltration of sym-HTPcH to form a hybrid interfacial buffer layer, affording perovskite solar cells (PSCs) with an average PCE value of up to 12.3%, which is a significant improvement with respect to the control cell without the meso-Al2O3 layer (4.21%) and is the highest value ever reported for Zn(ii) phthalocyanine based devices under AM1.5G standard conditions. A hysteresis test revealed that our device structure with the new HTM exhibited a balanced charge extraction behaviour.

17.
Z Gastroenterol ; 54(6): 541-7, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-27284928

RESUMEN

PURPOSE: To evaluate the safety and intermediate-term efficacy of percutaneous microwave ablation (MWA) in primary and secondary liver tumors using a third generation MWA device, under ultrasound guidance. PATIENTS AND METHODS: Sixty-two patients (median age 74 years, 73 % males) with 69 liver tumors were enrolled in this prospective observational study. Forty-seven patients (76 %) had hepatocellular carcinoma (HCC) and 15 (24 %) metastases. Median follow-up was 3.6 years. RESULTS: Median tumor diameter at contrast enhanced computed tomography was 23 mm (I-III quartiles, 18 - 31 mm). All procedures were performed percutaneously using a 2.45 GHz generator. Median ablation time was 10 minutes (I-III quartiles, 10 - 14 minutes). A single percutaneous antenna insertion was performed for 56/69 (81 %) of the tumors. Technical success was obtained in all tumors. Primary efficacy at 24 hours was achieved in 68/69 (99 %) tumors. The overall one-year cumulative local tumor progression rate was 15.1 % (95 % CI, 7.7 - 24.8 %) with no significant difference between HCC and metastases (p = 0.26). There was one procedure-related mortality (1.6 %) and one major bleeding (1.6 %). CONCLUSION: Microwave ablation is a valid option for thermal ablation of HCC and liver metastases with comparable complication rate to other local ablative procedures.


Asunto(s)
Ablación por Catéter/instrumentación , Ablación por Catéter/estadística & datos numéricos , Neoplasias Hepáticas/mortalidad , Neoplasias Hepáticas/cirugía , Microondas/uso terapéutico , Recurrencia Local de Neoplasia/mortalidad , Recurrencia Local de Neoplasia/prevención & control , Anciano , Ablación por Catéter/mortalidad , Estudios de Cohortes , Diseño de Equipo , Femenino , Estudios de Seguimiento , Humanos , Italia/epidemiología , Neoplasias Hepáticas/diagnóstico por imagen , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Recurrencia Local de Neoplasia/diagnóstico por imagen , Complicaciones Posoperatorias/mortalidad , Complicaciones Posoperatorias/prevención & control , Prevalencia , Estudios Prospectivos , Tasa de Supervivencia , Resultado del Tratamiento
18.
Biomicrofluidics ; 10(2): 024114, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-27051471

RESUMEN

Efficient lysis is critical when analyzing single cells in microfluidic droplets, but existing methods utilize detergents that can interfere with the assays to be performed. We demonstrate robust cell lysis without the use of detergents or other chemicals. In our method, cells are exposed to electric field immediately before encapsulation in droplets, resulting in cell lysis. We characterize lysis efficiency as a function of control parameters and demonstrate compatibility with enzymatic assays by measuring the catalysis of ß-glucosidase, an important cellulase used in the conversion of biomass to biofuel. Our method enables assays in microfluidic droplets that are incompatible with detergents.

19.
J Biol Regul Homeost Agents ; 29(4 Suppl): 87-94, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26652494

RESUMEN

Vitamin D is the main hormone regulating calcium phosphate homeostasis and mineral bone metabolism. Vitamin D deficiency is indeed extremely frequent in musculoskeletal diseases. Recent studies have shown that the treatment of osteoporosis needs to have an optimal vitamin D and calcium supplementation for its efficacy. Actually no agreement exists on the estabilished dose of vitamin D to administer in deficency states. We conducted a prospective study to develop a practical cholecalciferol loading dose regimen that would enable rapid correction of vitamin D deficiency. Sixty post-menopausal age woman were enrolled secondary to a fragility fracture (hip, vertebral, wrist) and screened for 25-hydroxyvitamin D (25(OH)D), calcium, and PTH at baseline (T0), after one month (T1), two months (T2), three months (T3) and six months (T4). Secondary to initial blood values of vitamin D patients were divided into 2 groups; the first group (group A, n=30) included patients with 25(OH)D values between 10-30 ng/ml and the second group (group B, n=30) with values under 10 ng/ml. Each group was then divided in 3 subgroups secondary to the randomized administered dose of 25(OH)D. By this, patients can alternatively receive 25000 UI two times monthly, 100000 UI monthly, 10000 UI (25 drops) weekly. The highest values of mean increase of 25(OH)D were observed in patients treated with 100000 UI. Patients treated with 10000 UI weekly did never achieve the target value. Additionally, as vitamin levels increased, pain intensity decreased. Vitamin D supplementation of 100000 UI monthly seems to be adequate to ensure that serum 25(OH)D values reach the threshold level; by this, it will confer the expected effects without risks of toxicity.

20.
J Biol Regul Homeost Agents ; 29(4 Suppl): 95-102, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26652495

RESUMEN

Osteoarthritis (OA) of the hip and knee causes pain and loss of joint mobility, leading to limitations in physical function. When conservative treatment fails total hip and knee replacement is a cost-effective surgical option. Patients have high expectations regarding functional outcome after these procedures. If such expectations are not met, they may still be dissatisfied with the outcome of a technically successful procedure. Recently, numerous studies reported that psychological factors can influence the outcome of total knee replacement (tkr) and total hip artrhoplasty with total hip replacement (thr). We conducted a prospective study on a consecutive sample of 280 patients affected by hip or knee OA who underwent total joint replacement. At patients’ admission, Harris Hip Score (HHS) and Knee Society Score (KSS) were used to assess pain and function. Furthermore, SF-36, Mini-Mental Status Examination (MMSE), Symptom Checklist-90-R (SCL-90-R), Coping Orientation to Problems Experienced (BRIEF-COPE) and the Amsterdam Preoperative Anxiety and Information Scale (APAIS) were administered. Patients had clinical and radio graphical follow up at 1, 3 and 6 months post-operatively. The HHS and KSS values before surgery showed a linear correlation with both SCL-90-R and MMSE. None of the investigated variables influenced post-operative HHS and KSS scores; however, the improvement of functional scores resulted conditioned by SCL-90-R values, VAS score, schooling and MMSE. Psychological factors and mental status in primary total hip and knee replacement can affect outcome and patient satisfaction. Strategies focused on identification and facing of these conditions must be considered to improve outcome of total replacement.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...