Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
Más filtros













Base de datos
Intervalo de año de publicación
1.
Luminescence ; 39(6): e4801, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38855811

RESUMEN

Atopic dermatitis (AD) is a persistent, inflammatory skin condition that impacts approximately 15 to 20% of children and 1 to 3% of adults globally. Common skin manifestations include papules, papulovesicular, and brown or red patches with swelling, crusting, and flaking. Therefore, the drug abrocitinib (ABR) was approved by the US FDA as an oral treatment for atopic dermatitis. The present study outlines the development of innovative, thermostable, and pH-stable organic solvent-free nitrogen-doped carbon dots (N@CQDs) synthesized through a one-step method for evaluating ABR with a notable quantum yield of 33.84% to minimize the use of organic solvents. Their cost-effectiveness, eco-friendly characteristics, and outstanding photocatalytic properties have established them as a promising alternative to conventional luminescent techniques like fluorescent dyes and luminous derivatization technique. The reaction of ABR with N@CQDs led to a significant decrease in the luminescent response of the produced green and stable carbon quantum dots at 513 nm. The detection range was determined to be 1.0-150.0 ng mL-1, with a lower limit of quantitation (LOQ) equal to 0.52 ng mL-1 based on the linear graph. The green method effectively used for analysis of ABR in pharmaceutical tablets and pharmacokinetic study with high sensitivity.


Asunto(s)
Carbono , Nitrógeno , Puntos Cuánticos , Puntos Cuánticos/química , Carbono/química , Nitrógeno/química , Humanos , Pirimidinas/química , Pirimidinas/sangre , Pirimidinas/síntesis química , Fluorometría , Colorantes Fluorescentes/química , Colorantes Fluorescentes/síntesis química , Solventes/química , Estructura Molecular
2.
Spectrochim Acta A Mol Biomol Spectrosc ; 320: 124596, 2024 Jun 04.
Artículo en Inglés | MEDLINE | ID: mdl-38850823

RESUMEN

People frequently administer Tizanidine (TIZ) to treat spasticity resulting from diseases like multiple sclerosis or spinal cord injuries. It also helps prevent muscle spasms. It helps to relax and release tense and stiff muscles by inhibiting specific nerve signals in the brain and spinal cord. The technique employed in this study made use of the unique ability of benzofurazan to confer fluorescent character when reacted with TIZ at specific conditions. This fluorogenic property was harnessed to evolve a remarkably sensitive, affordable, and selective method to quantify TIZ. The resulting yellow fluorescent product was observedat a wavelength beam of 532.9 nm, and an excitation wavelength beam of 474.9 nm was applied. By looking at the response across the TIZ concentration, the calibration chart's linearity was assessed in the range of 40-500 ng/mL. By computation, the approach's detection level (LOD) was determined to be 11.9 ng/mL, while the quantitation level was approximated to be 36 ng/mL. All pertinent factors impacting the strategy's efficacy were thoroughly inspected and adjusted accordingly. The proposed strategy was validated following the guidelines outlined by the ICH. The outcomes confirmed the method's capability for the accurate quantifying of TIZ in tablets, spiked plasma, and pharmaceutical assessing content uniformity.

3.
Spectrochim Acta A Mol Biomol Spectrosc ; 318: 124470, 2024 Oct 05.
Artículo en Inglés | MEDLINE | ID: mdl-38761476

RESUMEN

Recently, nanomaterials have attracted a lot of attention due to their potential as effective fluorescent nano-sensor probes. They were distinguishing substitutes for other luminescent techniques, such as fluorescent dyes and luminous derivatization, because of their affordability, environmental friendliness, and special photocatalytic properties. In the suggested work, a straightforward method was used to create boron and nitrogen carbon dots (B@CDs) with a good quantum yield value of 31.15 % utilizing boric acid and di-sodium EDTA. For the purpose of characterizing QDs, a variety of instruments were employed, such as transmission electron microscopy, fluorescence spectroscopy, X-ray FTIR, and UV-VIS spectroscopy. Nebivolol (NEB) is a cardiovascular medication used globally to treat congestive heart failure and hypertension, is in the meantime. For this reason, a brand-new, environmentally friendly analytical technique was created to determine the amount of human plasma, uniformity test, and commercial nebivolol (NEB) tablets. After gradually adding NEB, the response of B@CQDs was enhanced at 438 nm (excitation at 371 nm). The calibration graph ranged between 20 and 500 ng mL-1 with a quantification limit (LOQ) of 2.50 ng mL-1 and a detection limit (LOD) of 0.82 ng mL-1.


Asunto(s)
Boro , Carbono , Nebivolol , Puntos Cuánticos , Nebivolol/sangre , Nebivolol/análisis , Humanos , Carbono/química , Puntos Cuánticos/química , Boro/química , Tecnología Química Verde/métodos , Espectrometría de Fluorescencia/métodos , Límite de Detección , Espectroscopía Infrarroja por Transformada de Fourier , Comprimidos , Espectrofotometría Ultravioleta
4.
Luminescence ; 39(5): e4777, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38785072

RESUMEN

This study introduces a practical and cost-effective method for tracking diltiazem (DLZ) analytically. It utilizes a fluorimetric approach that relies on the modulation of fluorescence intensity of a dye called erythrosine B. Through a one-pot experiment performed in an acidic environment, a complex is rapidly formed between DLZ and erythrosine B. By observing the decrease in erythrosine B emission, a linear calibration plot is established, enabling the detection and quantification of DLZ concentrations ranging from 40 to 850 ng/ml. The estimated limits of detection and quantitation were 10.5 and 32.1 ng/ml, respectively. The variables affecting the DLZ-dye complex system were carefully adjusted. The validity of the approach was confirmed through a thorough evaluation based on the criteria set by ICH guidelines. The accuracy and precision of the methodology were evaluated, and the standard deviation and relative standard deviation were below 2. The strategy was successfully employed to analyze DLZ in tablets and capsules, and no significant variation between the proposed and reported methods as the values of the estimated t-test and F-test at five determinations were below 2.306 and 6.338, respectively. Notably, the method adheres to the principle of green chemistry by utilizing distilled water as the dispersing medium.


Asunto(s)
Diltiazem , Eritrosina , Diltiazem/análisis , Diltiazem/química , Eritrosina/química , Eritrosina/análisis , Espectrometría de Fluorescencia , Comprimidos/análisis , Concentración de Iones de Hidrógeno , Límite de Detección , Cápsulas/química , Colorantes Fluorescentes/química , Formas de Dosificación
5.
Luminescence ; 39(5): e4766, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38785095

RESUMEN

In this work, two validated approaches were used for estimating hydroxyzine HCl for the first time using resonance Rayleigh scattering (RRS) and spectrofluorimetric techniques. The suggested approaches relied on forming an association complex between hydroxyzine HCl and 2,4,5,7-tetraiodofluorescein (erythrosin B) reagent in an acidic media. The quenching in the fluorescence intensity of 2,4,5,7-tetraiodofluorescein by hydroxyzine at 551.5 nm (excitation = 527.5 nm) was used for determining the studied drug by the spectrofluorimetric technique. The RRS approach is based on amplifying the RRS spectrum at 348 nm upon the interaction of hydroxyzine HCl with 2,4,5,7-tetraiodofluorescein. The spectrofluorimetric methodology and the RRS methodology produced linear results within ranges of 0.15-1.5 µg ml-1 and 0.1-1.2 µg ml-1, respectively. LOD values for these methods were determined to be 0.047 µg ml-1 and 0.033 µg ml-1, respectively. The content of hydroxyzine HCl in its pharmaceutical tablet was estimated using the developed procedures with acceptable recoveries. Additionally, the application of four greenness and whiteness algorithms shows that they are superior to the previously reported method in terms of sustainability, economics, analytical performance, and practicality.


Asunto(s)
Algoritmos , Hidroxizina , Espectrometría de Fluorescencia , Hidroxizina/análisis , Hidroxizina/química , Antagonistas de los Receptores Histamínicos/análisis , Antagonistas de los Receptores Histamínicos/química , Dispersión de Radiación , Eritrosina/química , Eritrosina/análisis
6.
RSC Adv ; 14(24): 16982-16990, 2024 May 22.
Artículo en Inglés | MEDLINE | ID: mdl-38799220

RESUMEN

In this study, a phenothiazine-thiosemicarbazide (PTZDS) probe was synthesized and characterized. The synthesized PTZDS probe exhibited a yellow color, with a native fluorescence emission at λemission = 550 nm and λexcitation = 450 nm. Over other metal ions, the probe exhibited significant selectivity and sensitivity towards Hg2+ and Cu2+. The probe showed fluorescence quenching along with a minor shift in the absorbance spectra from 400 to 450 nm and 430 nm in the presence of Hg2+ and Cu2+, respectively. In addition, the color of the synthesized probe remarkedly faded with the addition of Hg2+ or Cu2+. Fluorescence measurements, infrared spectroscopy (IR), and density functional theory studies were employed to elucidate the binding process in the PTZDS + Cu2+ and PTZDS + Hg2+ sensor systems. Furthermore, photophysical investigations of the synthesized probe with Hg2+ and Cu2+ were performed. Finally, the probe was successfully employed as a solid-state thin layer chromatography (TLC) optical sensor for detecting Hg2+ and Cu2+ ions.

7.
Luminescence ; 39(4): e4748, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38644515

RESUMEN

In an acidic buffered solution, erythrosine B can react with amiodarone to form an association complex, which not only generates great enhancement in resonance Rayleigh scattering (RRS) spectrum of erythrosine B at 346.5 nm but also results in quenching of fluorescence spectra of erythrosine B at λemission = 550.4 nm/λexcitation = 528.5 nm. In addition, the formed erythrosine B-amiodarone complex produces a new absorbance peak at 555 nm. The spectral characteristics of the RRS, absorbance, and fluorescence spectra, as well as the optimum analytical conditions, were studied and investigated. As a result, new spectroscopic methods were developed to determine amiodarone by utilizing erythrosine B as a probe. Moreover, the ICH guidelines were used to validate the developed RRS, photometric, and fluorimetric methods. The enhancements in the absorbance and the RRS intensity and the decrease in the fluorescence intensity of the used probe were proportional to the concentration of amiodarone in ranges of 2.5-20.0, 0.2-2.5, and 0.25-1.75 µg/mL, respectively. Furthermore, limit of detection values were 0.52 ng/mL for the spectrophotometric method, 0.051 µg/mL for the RRS method, and 0.075 µg/mL for the fluorimetric method. Moreover, with good recoveries, the developed spectroscopic procedures were applied to analyze amiodarone in its commercial tablets.


Asunto(s)
Amiodarona , Eritrosina , Espectrometría de Fluorescencia , Amiodarona/análisis , Amiodarona/química , Eritrosina/química , Eritrosina/análisis , Antiarrítmicos/análisis , Antiarrítmicos/química , Estructura Molecular
8.
J Fluoresc ; 2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38625571

RESUMEN

For the first time, clemastine was estimated in this work utilizing two validated resonance Rayleigh scattering (RRS) and fluorimetric methods. The methods relied on forming an association complex in an acidic medium between eosin Y reagent and clemastine. In the spectrofluorimetric approach, the investigated drug was quantified by quenching the fluorescence-emission intensity of eosin Y at 543.5 nm. The RRS method relied on enhancing the RRS spectrum at 331.8 nm, which is produced when eosin Y interacts with clemastine. Suitable conditions were established for the reaction to achieve maximum sensitivity. The linear values obtained from the spectrofluorimetric approach and the RRS method fall into the ranges of 0.2-1.5 µg mL- 1 and 0.25-2.0 µg mL- 1, respectively. It was established that the detection limits for these methods were 0.045 µg mL- 1 and 0.059 µg mL- 1, respectively. The developed methodologies yielded acceptable recoveries when used to estimate the quantity of clemastine in its pharmaceutical tablet dosage form. Regarding the use of greener solvents that were chosen, the suggested and reported methods were compared with the help of the Green Solvents Selecting (GSST) tool for assessing hazardous solvents to achieve sustainability. Furthermore, analytical Eco scale and comprehensive assessments of whiteness, blueness, and greenness were carried out utilizing Modified NEMI, ComplexGAPI, and AGREE evaluation tools. Additionally, recently developed tools such as BAGI and RGB 12 were applied to assess the blueness and the whiteness of the suggested methods.

9.
Luminescence ; 2023 Dec 11.
Artículo en Inglés | MEDLINE | ID: mdl-38081623

RESUMEN

In this study, netilmicin (NTM) was selectively assessed in its dosage forms after a facile derivatization reaction. The proposed approach was based on the interaction between NTM and o-phthalaldehyde/2-mercaptoethanol (Roth's reagent). The reaction product was fluorometrically measured at λemission of 434 nm after λexcitation of 338 nm. All reaction conditions for achieving the optimum fluorescence switch-on activity were visualized and monitored. Moreover, the method was validated under ICH guidelines, and was linear over the range 30-210 ng/ml after plotting netilmicin concentrations against the corresponding fluorescence intensity values. In addition, the selectivity of the developed method was investigated against either the co-formulated drug (dexamethasone) or a common ophthalmic drop excipient (benzalkonium chloride) without interference from either of them. Furthermore, the developed method was applied to assay netilmicin in various samples of pharmaceutical eye drops with good recovery. Finally, multicriteria greenness and whiteness metrics were used to evaluate the sustainability, greenness, and whiteness of the approach. The applied tools were the AGREE algorithm, the RGB 12 algorithm, and HEXAGON.

10.
Int J Nanomedicine ; 18: 5831-5869, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37869062

RESUMEN

Purpose: Immunomodulatory and broad-spectrum antiviral activities have motivated the evaluation of curcumin for Coronavirus infection 2019 (COVID-19) management. Inadequate bioavailability is the main impediment to the therapeutic effects of oral Cur. This study aimed to develop an optimal curcumin transferosome-loaded thermosensitive in situ gel to improve its delivery to the lungs. Methods: Transferosomes were developed by using 33 screening layouts. The phospholipid concentration as well as the concentration and type of surfactant were considered independent variables. The entrapment efficiency (EE%), size, surface charge, and polydispersity index (PDI) were regarded as dependent factors. A cold technique was employed to develop thermosensitive in-situ gels. Optimized transferosomes were loaded onto the selected gels. The produced gel was assessed based on shape attributes, ex vivo permeability enhancement, and the safety of the nasal mucosa. The in vitro cytotoxicity, antiviral cytopathic effect, and plaque assay (CV/CPE/Plaque activity), and in vivo performance were evaluated after intranasal administration in experimental rabbits. Results: The optimized preparation displayed a particle size of 664.3 ± 69.3 nm, EE% of 82.8 ± 0.02%, ZP of -11.23 ± 2.5 mV, and PDI of 0.6 ± 0.03. The in vitro curcumin release from the optimized transferosomal gel was markedly improved compared with that of the free drug-loaded gel. An ex vivo permeation study revealed a significant improvement (2.58-fold) in drug permeability across nasal tissues of sheep. Histopathological screening confirmed the safety of these preparations. This formulation showed high antiviral activity against SARS-CoV-2 at reduced concentrations. High relative bioavailability (226.45%) was attained after the formula intranasally administered to rabbits compared to the free drug in-situ gel. The curcumin transferosome gel displayed a relatively high lung accumulation after intranasal administration. Conclusion: This study provides a promising formulation for the antiviral treatment of COVID-19 patients, which can be evaluated further in preclinical and clinical studies.


Asunto(s)
COVID-19 , Curcumina , Humanos , Animales , Conejos , Ovinos , Liposomas , Administración Intranasal , Curcumina/farmacología , SARS-CoV-2 , Portadores de Fármacos , Geles , Antivirales/farmacología , Tamaño de la Partícula
11.
Luminescence ; 38(10): 1836-1843, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37555794

RESUMEN

Naftidrofuryl is a vasodilator medication used for treating cerebral and peripheral vascular diseases. In this study, two spectroscopical techniques, spectrofluorimetric and resonance Rayleigh scattering (RRS), were utilized to quantify naftidrofuryl in its pharmaceutical samples. The developed methodologies in this study rely on a facile process of forming an association complex between erythrosine B reagent and naftidrofuryl under acidic conditions. The fluorimetric assay is based on the ability of naftidrofuryl to quench and decrease the native fluorescence intensity of the reagent when measured at λ emis . = 550 nm ( λ excit . = 526 nm). Under similar reaction conditions, the RRS method relies on the observed amplification in the RRS spectrum of the reagent at a wavelength of 577 nm following its interaction with naftidrofuryl. The methods exhibited linearity within the ranges 0.2-1.6 µg/ml (r2  = 0.999) and 0.1-1.4 µg/ml (r2  = 0.9994), with limit of quantitation values of 0.146 and 0.099 µg/ml, and limit of detection values of 0.048 and 0.032 µg/ml, for the fluorometric and the RRS methods, respectively. Moreover, the quenching between the dye and naftidrofuryl was studied using Stern-Volmer analysis, and the methodologies were experimentally optimized and validated. Additionally, acceptable recoveries were achieved when the procedures were applied to determine naftidrofuryl in pharmaceutical samples.


Asunto(s)
Eritrosina , Nafronil , Nafronil/análisis , Espectrometría de Fluorescencia/métodos , Dispersión de Radiación , Preparaciones Farmacéuticas
12.
Spectrochim Acta A Mol Biomol Spectrosc ; 299: 122839, 2023 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-37201330

RESUMEN

Netilmicin is an aminoglycoside antibiotic used to treat infections caused by a broad spectrum of Gram-negative and Gram-positive bacteria and is pharmaceutically formulated in ophthalmic dosage forms. In this study, two spectrofluorimetric approaches were designed and developed to switch-on the fluorescence activity of NTC. The first method, or Hantzsch (HNZ) method, was relied on measuring the generated fluorescence intensity upon the condensation of NTC with acetylacetone and formaldehyde (Hantzsch reaction) at λemis=483 nm/λexcit=425.5 nm. While the second fluorometric method (NHD method) was relied on measuring the generated fluorescence intensity upon the condensation of NTC with ninhydrin/phenylacetaldehyde at λemis=482.2 nm/λexcit=385.8 nm. The reaction conditions for the two approaches were well investigated and optimized. The selectivity study for the methods was investigated by determining NTC in the presence of the co-formulated drug (dexamethasone) and pharmaceutical excipients. The validation for two approaches was performed based on ICH guidelines, and ranges of linearity were 0.1-1.2 and 1.5-6.0 µg/mL, while LOD values were 0.039 and 0.207 µg/mL for the HNZ method and the NHD method, respectively. Finally, NTC has been determined in different ophthalmic preparations by the proposed approaches with adequate recovery values.


Asunto(s)
Netilmicina , Ninhidrina , Indicadores y Reactivos , Espectrometría de Fluorescencia/métodos , Formaldehído
13.
Luminescence ; 38(4): 477-486, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36880484

RESUMEN

A sensitive and selective phenothiazine-based sensor (PTZ) has been successfully synthesized. The sensor PTZ displayed specific identification of CN- 'turn-off' fluorescence responses with a quick reaction and strong reversibility in an acetonitrile:water (90:10, V/V) solution. The sensor PTZ for detecting CN- exhibits the marked advantages of quenching the fluorescence intensity, fast response time (60 s), and low value of the detection limit. The concentration that is authorized for drinking water by the WHO (1.9 µM) is far higher than the detection limit, which was found to be 9.11 × 10-9 . The sensor displays distinct colorimetric and spectrofluorometric detection for CN- anion due to the addition of CN- anion to the electron-deficient vinyl group of PTZ, which reduces intramolecular charge transfer efficiencies. The 1:2 binding mechanism of PTZ with CN- was validated by fluorescence titration, Job's plot, HRMS, 1 H NMR, FTIR analysis, and density functional theory (DFT) investigations, among other methods. Additionally, the PTZ sensor was successfully used to precisely and accurately detect cyanide anions in actual water samples.


Asunto(s)
Cianuros , Agua Potable , Cianuros/química , Aniones/química , Agua Potable/análisis , Espectrofotometría , Colorimetría/métodos
14.
Spectrochim Acta A Mol Biomol Spectrosc ; 295: 122616, 2023 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-36947938

RESUMEN

Principles of Green Analytical Chemistry recommended preferring using reagents from renewable sources and eliminating toxic reagents. Vachellia nilotica is a widespread plant throughout different parts of the world. In this study, using microwave energy, fluorescent carbon dots were synthesized for the first time from Vachellia nilotica pods. The morphology of the prepared carbon dots was characterized by SEM and TEM techniques, and the spectroscopic character exhibit green emission at 480 nm at λex = 386.5 nm. This fluorescence can be effectively quenched by adding Fe (III) ions (Method I). Furthermore, Vachellia nilotica pods were extracted by different solvents, including methanol, deionized water, absolute ethanol, acetone, acetonitrile, and DMF. The acetonitrile extract of Vachellia nilotica exhibited a strong red fluorescence emission at 673.9 at λex = 410 nm. Among various types of salt metals, only Fe (III) can effectively quench the fluorescence intensity of the acetonitrile extract (method II). Moreover, the bright yellow color of the aqueous extract can be changed into violet color. The absorbance of the resulted color can be spectrophotometrically measured at λ max = 530 nm (method III). The best analytical factors were optimized for the developed methods. The developed methods were applied to determine Fe (III) in different water samples.

15.
Luminescence ; 38(2): 92-98, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36427249

RESUMEN

Indigo Carmine is a hazardous dye and produces an allergic action for humans despite the excessive use of the dye in several industrial fields. A sensitive and simple fluorescent assay for determining Indigo Carmine relying on quenching of the fluorescent europium-doped carbon dots by the action of inner filter effect was developed. This sensing platform involved the preparation of europium-doped carbon dots from the hydrothermal carbonization of tannic acid and europium chloride, which was used as fluorescent reagent with a distinctive excitation/emission wavelength at 307/340 nm. Both excitation and emission fluorescence of prepared carbon dots can be successfully quenched by adding Indigo Carmine dye. The developed spectrofluorimetric method exhibits good linearity with the concentration of Indigo Carmine dye in the range of 1.5 to 10.0 µg/ml and provided a limit of detection (LOD) value of 0.40 µg/ml. Furthermore, the prepared carbon nanoparticles were identified and characterized by transmission electron microscopy (TEM), scanning electron microscopy (SEM), Fourier-transform infrared (FTIR), and ultraviolet (UV)-spectrophotometer techniques. In addition, the developed detecting approach was applied to determine Indigo Carmine in juice samples with acceptable recovery.


Asunto(s)
Carmin de Índigo , Puntos Cuánticos , Humanos , Carbono , Carmín , Europio , Colorantes , Taninos , Colorantes Fluorescentes
16.
Spectrochim Acta A Mol Biomol Spectrosc ; 287(Pt 1): 122124, 2023 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-36427404

RESUMEN

Turmeric, a spice known for its therapeutic benefits, is a major source of curcumin which is a polyphenol with anti-inflammatory properties. It aids in treating arthritis, anxiety, metabolic syndrome, liver disease, hyperlipidemia, and inflammatory diseases. In this study, a novel fluorescence probe was designed to detect the adulteration of curcumin by metanil yellow (a harmful artificial dye). The probe was synthesized from the carbonization and conversion of the Tannic acid-Eu3+ complex to bright fluorescence Eu-carbon dots in the presence of orthophosphoric acid. The size, morphological, and optical features of the formed Eu-carbon dots were characterized by UV, SEM, TEM, and FTIR techniques. Furthermore, the formed Eu-carbon dots possess unique fluorescence excitation and emission features at 307.5 nm and 340.6 nm, respectively. These fluorescence features can be successfully quenched upon the addition of metanil yellow dye. The value of quenching in the fluorescence intensity of the Eu-C-dots was directly proportional to the dye's concentration. The LOD value for the proposed method was 0.390 µg/mL with a linear range of 1.0-15.0 µg/mL. Furthermore, the methodology exhibited good recovery values for determining the studied dye without any interference from the presence of curcumin.


Asunto(s)
Curcuma , Curcumina , Polvos , Fluorescencia , Europio , Carbono
17.
J Pharm Biomed Anal ; 219: 114941, 2022 Sep 20.
Artículo en Inglés | MEDLINE | ID: mdl-35905532

RESUMEN

Nitazoxanide is an antimicrobial compound that was originally developed as an antiprotozoal drug. Recently nitazoxanide has been identified as broad-spectrum antiviral agent and redirected for the remediation of some respiratory tract viral infections. In this study, the spectrofluorimetric technique has been applied to determine Nitazoxanide (NTX) in tablets or its metabolite, tizoxanide (TZD), in human urine samples. The developed methodology is based on oxidizing NTX (non-fluorescence) into a highly fluorescent product by sodium hypochlorite. The fluorescence emission intensity was measured at 436.5 nm after fluorescence excitation at 362.5 nm. After optimizing all conditions, the analytical procedures and bio-analytical steps were evaluated and validated using ICH and FDA criteria, respectively. The method linearity, LOQ, and LOD values of NTX were 1.0-5.0 µg/mL, 0.434, and 0.143 µg/mL, respectively. The other novelty side of the presented work is the application of cobalt ferrite (CoFe2O4) nanoparticles (NPs) as a magnetic solid-phase for the pre-concentration and extraction process. The synthesized magnetic nanoparticles were characterized by scanning electron microscope and zeta sizer techniques. Finally, the utilized magnetic nanoparticles exhibited good recovery results for pre-concentration and extraction of NTX or its metabolite from spiked and real human urine samples, respectively.


Asunto(s)
Ácido Hipocloroso , Nanopartículas , Cobalto , Compuestos Férricos , Colorantes Fluorescentes , Humanos , Nitrocompuestos , Oxidación-Reducción , Tiazoles
18.
Sci Rep ; 12(1): 6953, 2022 04 28.
Artículo en Inglés | MEDLINE | ID: mdl-35484380

RESUMEN

Polyvinylpyrrolidone stabilized silver nanoparticles (PV-AgNPs) were synthesized from AgNO3/trisodium citrate and with the assistance of microwave energy. The synthesized PV-AgNPs were found to own an actual peroxidase mimicking activity. This catalytic activity can oxidize the non-fluorescence reagent (o-phenylenediamine) to a high fluorescence reaction product (2,3-diaminophenazine). The reaction product exhibited a fluorescence emission at 563 nm upon the excitation at 420. Among many metals, only mercury (II) ions can inhibit the catalytic activity of PV-AgNPs nanozyme. Accordingly, the fluorescence intensity of the reaction product has been successfully quenched. This quenching effect in the fluorescence intensity was directly proportional to the concentration of mercury (II). Depending on this finding, a simple, cost-effective, and selective spectrofluorimetric approach has been designed for mercury (II) detection in water samples. The linear relationship between the inhibition in fluorescence intensity and mercury (II) concentration was found in 20-2000 nM with a detection limit of 8.9 nM.


Asunto(s)
Mercurio , Nanopartículas del Metal , Peróxido de Hidrógeno , Iones , Peroxidasas , Fenilendiaminas , Plata
19.
Luminescence ; 37(6): 1001-1008, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35412020

RESUMEN

Selective fluorometric detection and determination of uranium ions is provided here using a novel fluorescent reagent, namely (E)-4-([4-hydroxynaphthalen-1-yl]diazenyl)-N-(5-methyleisoxazol-3-yl) benzenesulfonamide (UVI reagent). The UVI reagent offers a selective fluorescence enhancement behaviour at emission wavelength = 557 nm. The parameters affecting fluorometric detection of uranium ions, such as the pH, solvent type, ligand concentration, interaction time, and interfering ions, were investigated and adjusted. The proposed UVI reagent can detect and determine uranium ions even at low concentrations, for which the obtained limit of detection was 0.1 ppm. Additionally, this proposed determination protocol was successfully used to detect, monitor, and determine uranium ions in actual water samples.


Asunto(s)
Uranio , Iones , Espectrometría de Fluorescencia , Sulfonamidas , Agua , Bencenosulfonamidas
20.
Luminescence ; 37(3): 448-454, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35023289

RESUMEN

In this study, a fluorescence azothiazol-benzenesulfonamide derivative (M-sensor) was prepared for the determination of Mg2+ ions in different samples. The utilized M-sensor exhibited an emission fluorescence activity at 587 nm upon excitation at 537 nm. The developed method was based on the quenching effect of Mg2+ ions on the fluorescence intensity of the M-sensor with the above-mentioned fluorescence features. Furthermore, the utilized M-sensor was complexed with Mg2+ ions in the molar ratio of 1:1 (Mg2+ to M-sensor) and the selectivity of M-sensor toward Mg2+ against other metals ions, and the reversibility and reusability of the sensor were studied and verified. After optimization of the fluorometric detection, the quenching effect was directly proportional to the increase in the concentration of Mg2+ in the linear range 100-600 ng ml-1 with a limit of detection value of 18 ng ml-1 . The fluorescence sensor was successfully applied with good recovery for the determination of Mg2+ in water samples and different pharmaceutical samples (ampoules and suspension) without any interference from aluminium.


Asunto(s)
Magnesio , Agua , Iones , Espectrometría de Fluorescencia/métodos , Sulfonamidas , Bencenosulfonamidas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA