Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Invest Radiol ; 54(6): 349-355, 2019 06.
Artículo en Inglés | MEDLINE | ID: mdl-30688685

RESUMEN

OBJECTIVES: In human menisci, we aimed to investigate whether calcium pyrophosphate crystal deposition (CPPD) affects biomechanical and quantitative MR properties, and their zonal distribution. MATERIALS AND METHODS: From 9 cadaveric knees, sectioned triangular meniscus pieces were harvested. Samples were classified into "normal" or "CPPD" groups based upon visual inspection. Micro computed tomography scan verified CPPD. Using magnetic resonance imaging, ultrashort echo time (UTE) T2* and spin echo (SE) T2, quantitative values in 3 zones (red, red-white, and white) were determined. Using biomechanical test, indentation forces in the same zones were determined. Effects of CPPD and meniscal zone on indentation force and quantitative MR values were compared. RESULTS: On UTE MRI scans, CPPD-affected menisci exhibited punctate dark regions, found mostly (92%) in avascular white and red-white zones. Indentation forces were significantly higher for CPPD samples in the red-white (all P < 0.02) and white (all P < 0.004) zones but not in the vascular red zone (all P > 0.2). Similarly, UTE T2* red zone values were similar between both groups (~6.6 milliseconds, P = 0.8), whereas in the red-white and white zones, CPPD samples had significantly lower values (~5.1 milliseconds, P = 0.005 to 0.007). In contrast, SE T2 values showed no difference with CPPD (P = 0.12 to 0.16). UTE T2*, but not SE T2, correlated significantly with indentation force (R = -0.29, P = 0.009). CONCLUSIONS: Dark CPP deposits were detectable on UTE images featuring high signal intensity from surrounding meniscal tissue. Preliminary results indicate that CPP deposits were almost exclusively found in the avascular zones. Compared with normal, CPPD menisci featured higher indentation stiffness and lower UTE T2* values in the affected zones.


Asunto(s)
Pirofosfato de Calcio/metabolismo , Procesamiento de Imagen Asistido por Computador/métodos , Articulación de la Rodilla/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Menisco/diagnóstico por imagen , Fenómenos Biomecánicos , Cadáver , Femenino , Humanos , Articulación de la Rodilla/metabolismo , Masculino , Menisco/metabolismo , Persona de Mediana Edad , Microtomografía por Rayos X
2.
Invest Radiol ; 54(1): 32-38, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30157099

RESUMEN

OBJECTIVES: The objective of this study was to compare the diagnostic performance and confidence of conventional, optimized, and ultrashort time to echo (UTE) magnetic resonance (MR) protocols for detection of simulated lumbar spondylolysis in human cadavers. In addition, we sought to demonstrate the feasibility of the UTE technique in subjects with and without spondylolysis. MATERIALS AND METHODS: Four human lumbar spine specimens with 46 individual pars interarticularis were randomly left intact (n = 26) or received experimental osteotomy (n = 20) using a microsurgical saw to simulate spondylolysis. The specimens were imaged using a computed tomography (CT) scan along with 3 "Tiers" of MR protocols at 3 T: Tier 1, conventional lumbar MR protocol; Tier 2, optimized conventional protocol consisting of a sagittal oblique spoiled gradient recall echo and axial oblique T1 and short tau inversion recovery sequences; and Tier 3, a sagittal UTE MR sequence. Two blinded readers evaluated the images using a 4-point scale (1 = spondylolysis certainly absent, 2 = probably absent, 3 = probably present, 4 = certainly present) at each individual pars. For each imaging protocol, diagnostic performance (sensitivity, specificity, and area under the receiver operating characteristic curve, using the surgical osteotomy as the reference) and confidence were assessed and compared using the McNemar test. Furthermore, 2 human subjects were imaged with the conventional and UTE MR protocols to demonstrate feasibility in vivo. RESULTS: Diagnostic performance was moderate for Tiers 1 and 2, with a moderate sensitivity (0.70 to 0.75) and high (1.00) specificity. In contrast, CT and Tier 3 UTE MR imaging had both high sensitivity (1.00) and specificity (1.00). The sensitivities of CT or Tier 3 were statistically greater than Tier 1 sensitivity (P = 0.041) and neared statistical significance when compared with Tier 2 sensitivity (P = 0.074). Area under the receiver operating characteristic curve was also significantly greater for CT and Tier 3 (each area = 1.00), compared with the areas for Tier 1 (0.89, P = 0.037) or Tier 2 (0.873, P = 0.024). Diagnostic confidences of CT or Tier 3 were much greater than other Tiers: Both Tiers 1 and 2 had a large percentage of uncertain (>60%, P < 0.001) or wrong interpretations (>10%, P < 0.001), unlike CT or Tier 3 (0% uncertain or wrong interpretations). Preliminary in vivo UTE images clearly depicted intact and fractured pars. CONCLUSIONS: Our study demonstrated that the detection of pars fractures using a single sagittal UTE MR sequence is superior in performance and confidence to conventional and optimized MR protocols at 3 T, whereas matching those from CT evaluation. Furthermore, we demonstrated the feasibility of in vivo application of the UTE sequence in subjects with and without spondylolysis.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Espondilólisis/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Cadáver , Femenino , Humanos , Vértebras Lumbares/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Curva ROC , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
3.
Quant Imaging Med Surg ; 6(6): 744-755, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28090450

RESUMEN

Human lumbar spine is composed of multiple tissue components that serve to provide structural stability and proper nutrition. Conventional magnetic resonance (MR) imaging techniques have been useful for evaluation of IVD, but inadequate at imaging the discovertebral junction and ligamentous tissues due primarily to their short T2 nature. Ultrashort time to echo (UTE) MR techniques acquire sufficient MR signal from these short T2 tissues, thereby allowing direct and quantitative evaluation. This article discusses the anatomy of the lumbar spine, MR techniques available for morphologic and quantitative MR evaluation of long and short T2 tissues of the lumbar spine, considerations for T2 relaxation modeling and fitting, and existing and new techniques for spine image post-processing, focusing on segmentation. This article will be of interest to radiologic and orthopaedic researchers performing lumbar spine imaging.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...