Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
J Cardiovasc Surg (Torino) ; 65(3): 289-295, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38511306

RESUMEN

BACKGROUND: The redundant leaflet tissue and annular pathology of Barlow disease can make surgical repair challenging. We examined perioperative and late outcomes of a large cohort of patients with Barlow disease undergoing surgical repair. METHODS: Patients included in this analysis underwent mitral valve repair from 01/2004-11/2021 by a single surgeon. RESULTS: Of 2798 patients undergoing mitral valve operations, 46% (N.=1292) had degenerative pathology and 7% (N.=184) had Barlow disease. Of the 179 Barlow patients, median age at surgery was 62 (51-70) years; 64% were male (115/179). Rates of non-resectional cordal repair and resectional repair were 86% (154/179) and 14% (25/179). Among patients undergoing non-resectional repair, the median number of cordal pairs inserted on the anterior and posterior leaflets was 2 (2-3) and 4 (3-4). Incidence of return to bypass for systolic anterior motion of the mitral valve, perioperative death, stroke, and renal failure was 2% (4/179), 1% (2/179), 0% (0/179), and 0% (0/179). Rates of clinical and echocardiographic follow-up were 93% (165/177) and 89% (157/177). Median time to latest postoperative clinical and echocardiographic follow-up was 2.4 (0.8-6.1) and 2.1 (0.6-4.7) years. Mitral regurgitation grade at latest follow-up or time of repair failure was none/trace, mild, mild to moderate, and severe in 63% (98/157), 26% (41/157), 8% (12/157), and 4% (6/157); five of six patients with severe MR underwent reoperation. Since 2011 97% (139/144) of patients underwent cordal repair without resection. CONCLUSIONS: Non-resectional artificial cordal repair is safe and feasible in almost all patients with Barlow valves and is associated with excellent mid-term results.


Asunto(s)
Anuloplastia de la Válvula Mitral , Válvula Mitral , Humanos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Válvula Mitral/cirugía , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Resultado del Tratamiento , Estudios Retrospectivos , Factores de Tiempo , Anuloplastia de la Válvula Mitral/efectos adversos , Anuloplastia de la Válvula Mitral/instrumentación , Prolapso de la Válvula Mitral/cirugía , Prolapso de la Válvula Mitral/diagnóstico por imagen , Prolapso de la Válvula Mitral/fisiopatología , Complicaciones Posoperatorias/etiología , Factores de Riesgo , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/fisiopatología , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Recuperación de la Función
2.
Res Sq ; 2024 Jan 16.
Artículo en Inglés | MEDLINE | ID: mdl-38313271

RESUMEN

Purpose: Early detection of acute brain injury (ABI) is critical for improving survival for patients with extracorporeal membrane oxygenation (ECMO) support. We aimed to evaluate the safety of ultra-low-field portable MRI (ULF-pMRI) and the frequency and types of ABI observed during ECMO support. Methods: We conducted a multicenter prospective observational study (NCT05469139) at two academic tertiary centers (August 2022-November 2023). Primary outcomes were safety and validation of ULF-pMRI in ECMO, defined as exam completion without adverse events (AEs); secondary outcomes were ABI frequency and type. Results: ULF-pMRI was performed in 50 patients with 34 (68%) on venoarterial (VA)-ECMO (11 central; 23 peripheral) and 16 (32%) with venovenous (VV)-ECMO (9 single lumen; 7 double lumen). All patients were imaged successfully with ULF-pMRI, demonstrating discernible intracranial pathologies with good quality. AEs occurred in 3 (6%) patients (2 minor; 1 serious) without causing significant clinical issues.ABI was observed in ULF-pMRI scans for 22 patients (44%): ischemic stroke (36%), intracranial hemorrhage (6%), and hypoxic-ischemic brain injury (4%). Of 18 patients with both ULF-pMRI and head CT (HCT) within 24 hours, ABI was observed in 9 patients with 10 events: 8 ischemic (8 observed on ULF-oMRI, 4 on HCT) and 2 hemorrhagic (1 observed on ULF-pMRI, 2 on HCT). Conclusions: ULF-pMRI was shown to be safe and valid in ECMO patients across different ECMO cannulation strategies. The incidence of ABI was high, and ULF-pMRI may more sensitive to ischemic ABI than HCT. ULF-pMRI may benefit both clinical care and future studies of ECMO-associated ABI.

3.
Diagnostics (Basel) ; 12(11)2022 Nov 19.
Artículo en Inglés | MEDLINE | ID: mdl-36428931

RESUMEN

(1) Background: Fifty percent of patients supported on veno-arterial extracorporeal membrane oxygenation (VA-ECMO) are concurrently supported with an intra-aortic balloon pump (IABP). Acute brain injury (ABI) is a devastating complication related to ECMO and IABP use. The standard of care for ABI diagnosis requires transport to a head CT (HCT) scanner. Recent data suggest that point-of-care (POC) magnetic resonance imaging (MRI) is safe and may be effective in diagnosing ABI in ECMO patients; however, no data exist in patients supported on ECMO with an IABP. We report pre-clinical safety data and a case series to evaluate the safety and feasibility of POC brain MRI in ECMO patients supported with IABP. (2) Methods: Prior to patient use, ex vivo testing with an IABP catheter within the Swoop® Portable MRI (0.064 T) System™ was conducted. After IRB approval, clinical testing was performed for the safety and feasibility of early ABI detection. (3) Results: No deflection force was measured with a 7.5 French Maquet Linear IABP within the 0.064 T field. Three adult ECMO patients (average age: 40 years; 67% female) supported with IABP completed four POC brain MRI exams (median exam time: 30 min). Multiple signal abnormalities were detected on the POC brain MRI, corresponding to HCT results. (4) Conclusions: Our preliminary results suggest that adult VA-ECMO patients with IABP support can be safely imaged with low-field POC brain MRI in the intensive care unit, allowing for the early and bedside imaging of patients.

4.
Crit Care ; 26(1): 119, 2022 04 30.
Artículo en Inglés | MEDLINE | ID: mdl-35501837

RESUMEN

BACKGROUND: To assess the safety and feasibility of imaging of the brain with a point-of-care (POC) magnetic resonance imaging (MRI) system in patients on extracorporeal membrane oxygenation (ECMO). Early detection of acute brain injury (ABI) is critical in improving survival for patients with ECMO support. METHODS: Patients from a single tertiary academic ECMO center who underwent head CT (HCT), followed by POC brain MRI examinations within 24 h following HCT while on ECMO. Primary outcomes were safety and feasibility, defined as completion of MRI examination without serious adverse events (SAEs). Secondary outcome was the quality of MR images in assessing ABIs. RESULTS: We report 3 consecutive adult patients (median age 47 years; 67% male) with veno-arterial (n = 1) and veno-venous ECMO (n = 2) (VA- and VV-ECMO) support. All patients were imaged successfully without SAEs. Times to complete POC brain MRI examinations were 34, 40, and 43 min. Two patients had ECMO suction events, resolved with fluid and repositioning. Two patients were found to have an unsuspected acute stroke, well visualized with MRI. CONCLUSIONS: Adult patients with VA- or VV-ECMO support can be safely imaged with low-field POC brain MRI in the intensive care unit, allowing for the assessment of presence and timing of ABI.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Adulto , Encéfalo/diagnóstico por imagen , Oxigenación por Membrana Extracorpórea/métodos , Estudios de Factibilidad , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
6.
J Am Soc Mass Spectrom ; 27(5): 786-94, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-26860087

RESUMEN

Ion mobility spectrometry-mass spectrometry (IMS-MS) techniques are used to study the general effects of phosphorylation on peptide structure. Cross sections for a library of 66 singly phosphorylated peptide ions from 33 pairs of positional isomers, and unmodified analogues were measured. Intrinsic size parameters (ISPs) derived from these measurements yield calculated collision cross sections for 85% of these phosphopeptide sequences that are within ±2.5% of experimental values. The average ISP for the phosphoryl group (0.64 ± 0.05) suggests that in general this moiety forms intramolecular interactions with the neighboring residues and peptide backbone, resulting in relatively compact structures. We assess the capability of ion mobility to separate positional isomers (i.e., peptide sequences that differ only in the location of the modification) and find that more than half of the isomeric pairs have >1% difference in collision cross section. Phosphorylation is also found to influence populations of structures that differ in the cis/trans orientation of Xaa-Pro peptide bonds. Several sequences with phosphorylated Ser or Thr residues located N-terminally adjacent to Pro residues show fewer conformations compared to the unmodified sequences.


Asunto(s)
Iones/química , Espectrometría de Masas/métodos , Fosfopéptidos/química , Iones/metabolismo , Isomerismo , Fosfopéptidos/metabolismo , Fosforilación , Prolina/química , Prolina/metabolismo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...