Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
1.
J Ultrasound Med ; 43(3): 513-523, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38050780

RESUMEN

OBJECTIVES: The number and distribution of lung ultrasound (LUS) imaging artifacts termed B-lines correlate with the presence of acute lung disease such as infection, acute respiratory distress syndrome (ARDS), and pulmonary edema. Detection and interpretation of B-lines require dedicated training and is machine and operator-dependent. The goal of this study was to identify radio frequency (RF) signal features associated with B-lines in a cohort of patients with cardiogenic pulmonary edema. A quantitative signal indicator could then be used in a single-element, non-imaging, wearable, automated lung ultrasound sensor (LUSS) for continuous hands-free monitoring of lung fluid. METHODS: In this prospective study a 10-zone LUS exam was performed in 16 participants, including 12 patients admitted with acute cardiogenic pulmonary edema (mean age 60 ± 12 years) and 4 healthy controls (mean age 44 ± 21). Overall,160 individual LUS video clips were recorded. The LUS exams were performed with a phased array probe driven by an open-platform ultrasound system with simultaneous RF signal collection. RF data were analyzed offline for candidate B-line indicators based on signal amplitude, temporal variability, and frequency spectrum; blinded independent review of LUS images for the presence or absence of B-lines served as ground truth. Predictive performance of the signal indicators was determined with receiving operator characteristic (ROC) analysis with k-fold cross-validation. RESULTS: Two RF signal features-temporal variability of signal amplitude at large depths and at the pleural line-were strongly associated with B-line presence. The sensitivity and specificity of a combinatorial indicator were 93.2 and 58.5%, respectively, with cross-validated area under the ROC curve (AUC) of 0.91 (95% CI = 0.80-0.94). CONCLUSION: A combinatorial signal indicator for use with single-element non-imaging LUSS was developed to facilitate continuous monitoring of lung fluid in patients with respiratory illness.


Asunto(s)
Edema Pulmonar , Síndrome de Dificultad Respiratoria , Humanos , Persona de Mediana Edad , Anciano , Adulto Joven , Adulto , Estudios Prospectivos , Pulmón/diagnóstico por imagen , Sensibilidad y Especificidad , Ultrasonografía/métodos
2.
J Correct Health Care ; 29(6): 411-420, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37917880

RESUMEN

People experiencing incarceration in the United States receive much of their health care outside of custodial settings. Optimizing care in this setting requires further understanding of the training and experiences of noncustodial health care workers. We conducted a cross-sectional, exploratory survey of health care workers at a single academic institution to assess their training and experiences related to caring for this patient population. Of 333 respondents, 94.1% had cared for patients experiencing incarceration but only 22.5% had received any formal training, with 94.6% somewhat or very interested in further training. Common challenges included lack of privacy, difficulty obtaining patient history or completing an examination, and patient distress. Health care workers frequently experience challenges and report strong interest in further training to address knowledge gaps, and further detailed investigation is needed.


Asunto(s)
Atención a la Salud , Personal de Salud , Humanos , Estados Unidos , Estudios Transversales , Personal de Salud/educación , Instituciones Académicas , Atención al Paciente
3.
J Am Soc Echocardiogr ; 36(11): 1127-1139, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37925190

RESUMEN

The COVID-19 pandemic has evolved since the publication of the initial American Society of Echocardiography (ASE) statements providing guidance to echocardiography laboratories. In light of new developments, the ASE convened a diverse, expert writing group to address the current state of the COVID-19 pandemic and to apply lessons learned to echocardiography laboratory operations in future pandemics. This statement addresses important areas specifically impacted by the current and future pandemics: (1) indications for echocardiography, (2) application of echocardiographic services in a pandemic, (3) infection/transmission mitigation strategies, (4) role of cardiac point-of-care ultrasound/critical care echocardiography, and (5) training in echocardiography.


Asunto(s)
COVID-19 , Humanos , Estados Unidos/epidemiología , COVID-19/epidemiología , Pandemias , Ecocardiografía , Sociedades Médicas
4.
Ultrasound Med Biol ; 49(12): 2451-2458, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37718123

RESUMEN

OBJECTIVE: Bacterial loads can be effectively reduced using cavitation-mediated focused ultrasound, or histotripsy. In this study, gram-negative bacteria (Escherichia coli) in suspension were used as model bacteria to evaluate the effectiveness of two regimens of histotripsy treatments: cavitation histotripsy (CH) and boiling histotripsy (BH). METHODS: Ten-milliliter volumes of Escherichia coli were treated at different negative focal pressure amplitudes and over time periods up to 40 min. Cavitation activity was characterized with coaxial passive cavitation detection (PCD) and synchronized plane wave B-mode imaging. RESULTS: CH treatments exhibited a threshold behavior that was consistent with PCD metrics of cavitation. Above the threshold, bacterial inactivation followed a monotonically increasing log-linear relationship that indicated an exponential inactivation rate. BH exhibited no threshold, but instead followed a different monotonically increasing inactivation rate. Inactivation rates were larger for BH at or below the CH threshold, and larger for CH substantially above the threshold. CH studies performed at different pulse lengths at the same duty cycle had similar inactivation rates, suggesting that at any given pressure amplitude, the "on time" was the most important variable for inactivating E. coli. The maximum inactivation was produced by CH at the highest pressure amplitudes used, leading to a log reduction >4.2 for a 40 min treatment. CONCLUSION: The results of this study suggest that both CH and BH can be used to inactivate E. coli in suspension, with the optimal regimen depending on the attainable peak negative focal pressure at the target.


Asunto(s)
Ultrasonido Enfocado de Alta Intensidad de Ablación , Litotricia , Escherichia coli , Ultrasonido Enfocado de Alta Intensidad de Ablación/métodos , Litotricia/métodos , Fantasmas de Imagen
5.
Cureus ; 14(10): e30927, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36465735

RESUMEN

Background Cardiogenic shock (CS) is critical end-organ hypoperfusion due to reduced cardiac output. Early therapy, such as vasoactive agents or the initiation of mechanical circulatory support (MCS), requires early diagnosis and is associated with better outcomes. A novel ultrasound platform (GE Healthcare, Milwaukee, WI) has semi-automated imaging software (SAIS), which could simplify the point-of-care ultrasound (POCUS) diagnosis of CS. We assessed the feasibility of using POCUS with SAIS in patients in shock, determined the ability of SAIS to identify the subset of patients with CS, and described the process and outcome of care of patients with vs. without CS after presenting to Emergency Department (ED) with hypotension. Methods This prospective case-control study was conducted at an urban ED. Physicians with prior POCUS education received one hour of training with the study device. The qualitative ejection fraction was determined by visual assessment. SAIS measurements of hemodynamics were made with the study device and included left ventricle outflow tract velocity time integral (LVOT VTI), inferior vena cava collapsibility or distensibility indices, and pulmonary B-line assessment. ED patients with a systolic blood pressure ≤ 90 mmHg or need for a vasopressor initiation in the ED were enrolled. The diagnosis of CS was determined by a medical record review. All data were summarized descriptively. Results Twenty-nine cases underwent POCUS, and 87 controls did not. Baseline characteristics, process, and outcome of care were similar between groups. Seventy-nine percent (79%) of cases had a complete POCUS with SAIS. Of these, 55% had reduced LVOT VTI, 38% had IVC collapsibility <50%, and 48% of cases had a B-line pattern consistent with pulmonary edema. The mean LVOT VTI for cases with CS was 9.4± 5.4 cm; the mean LVOT VTI for cases without CS was 15.2 ± 6.0 cm. Among patients who did not undergo POCUS, 31 (36%) had a formal echocardiogram, and eight (9%) had a final diagnosis of cardiogenic shock during hospitalization. Conclusion Physicians with one hour of platform-specific training were able to implement POCUS with SAIS among patients who present with shock. POCUS with SAIS may aid in the early recognition of CS.

6.
Neurocrit Care ; 37(1): 200-208, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35314968

RESUMEN

BACKGROUND: Cardiac dysfunction is common in the days after severe traumatic brain injury (TBI) and may contribute to hypotension episodes, leading to worse outcomes. Little is known about cardiac function in the minutes and hours immediately following TBI. By using fluid percussion TBI in a swine model, we aimed to characterize the immediate post injury cardiac function. METHODS: Intubated, anesthetized immature (25.8 ± 1.5 kg) female swine were subjected to severe fluid percussion TBI (4.2 ± 0.2 atm). Beginning at 45 min, simulating hospital arrival, all animals were resuscitated with normal saline (NS), mannitol, and phenylephrine as needed to maintain a cerebral perfusion pressure more than 60 mm Hg and intracranial pressure (ICP) less than 20 mm Hg. Primary outcomes of cardiac function were cardiac output measured by thermodilution and transesophageal echo measurements of cardiac function recorded at prespecified time points and tested for trends over time using linear regression with spline at the time of resuscitation onset. Secondary outcomes included hemodynamic measurements, ICP, and cerebral perfusion pressure. RESULTS: Eighteen animals were included. Post-TBI hemodynamic changes demonstrated an early decrease in mean arterial pressure and cerebral perfusion pressure with a corresponding increase in heart rate and ICP. Immediately after injury, there was a significant decrease in both left atrial area and tissue Doppler imaging e' of the LV lateral wall. In addition, there was a simultaneous increase in LV end diastolic diameter and increase in E/e' ratio of the lateral mitral annulus. All other transesophageal echo measurements demonstrated no significant changes throughout the duration of the experiment. CONCLUSIONS: Traumatic brain injury is associated with cardiac dysfunction and increased mortality, however there is still a limited understanding of the hemodynamic and echocardiographic response associated with TBI. In this study we demonstrate the hemodynamic and echocardiographic changes in the early stages of TBI in swine. The authors hope that these results may help better understanding on the management of patients with severe head injury.


Asunto(s)
Lesiones Traumáticas del Encéfalo , Lesiones Encefálicas , Cardiopatías , Animales , Lesiones Traumáticas del Encéfalo/complicaciones , Lesiones Traumáticas del Encéfalo/diagnóstico por imagen , Femenino , Cardiopatías/complicaciones , Presión Intracraneal/fisiología , Porcinos , Función Ventricular Izquierda
7.
Echocardiography ; 39(2): 240-247, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-35034372

RESUMEN

INTRODUCTION: Cardiac point-of-care ultrasound (c-POCUS) is an increasingly implemented diagnostic tool with the potential to guide clinical management. We sought to characterize and analyze the existing c-POCUS literature with a focus on the temporal trends and differences across specialties. METHODS: A literature search for c-POCUS and related terms was conducted using Ovid (MEDLINE and Embase) and Web of Science databases through 2020. Eligible publications were classified by publication type and topic, author specialty, geographical region of senior author, and journal specialty. RESULTS: The initial search produced 1761 potential publications. A strict definition of c-POCUS yielded a final total of 574 cardiac POCUS manuscripts. A yearly increase in c-POCUS publications was observed. Nearly half of publications were original research (48.8%) followed by case report or series (22.8%). Most publications had an emergency medicine senior author (38.5%), followed by cardiology (20.8%), anesthesiology (12.5%), and critical care (12.5%). The proportion authored by emergency medicine and cardiologists has decreased over time while those by anesthesiology and critical care has generally increased, particularly over the last decade. First authorship demonstrated a similar trend. Articles were published in emergency medicine (24.4%) and cardiology journals (20.5%) with comparable frequency. CONCLUSION: The annual number of c-POCUS publications has steadily increased over time, reflecting the increased recognition and utilization of c-POCUS. This study can help inform clinicians of the current state of c-POCUS and augment the discussion surrounding barriers to continued adoption across all specialties.


Asunto(s)
Sistemas de Atención de Punto , Pruebas en el Punto de Atención , Cuidados Críticos , Corazón , Humanos , Ultrasonografía
8.
Resuscitation ; 134: 76-80, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30365974

RESUMEN

INTRODUCTION: Hemodynamic-guided cardiopulmonary resuscitation (HGCPR) achieves better outcomes than standard resuscitation. Currently, HGCPR requires an invasive procedure, infeasible during resuscitation. Non-invasive measures of blood flow could provide useful hemodynamic guidance to rescuers. OBJECTIVE: We describe initial efforts to develop a device that detects, analyzes, and measures the velocity of carotid artery blood flow (CABF) towards the brain at pre-arrest baseline ('baseline') and during cardiopulmonary resuscitation, here tested in a swine model of cardiac arrest (CA). A key element of that device consists of non-imaging diagnostic ultrasound, due to its simplicity and small form factor, hence potential for deployment during HGCPR in a bandage placed on the neck. METHODS: Sixteen mixed-breed domestic swine were sedated, anesthetized and paralyzed, followed by endotracheal intubation and mechanical ventilation. Cardiac arrest was induced with a 3-s 100 mA transthoracic shock or bolus of fentanyl, after which all animals received mechanical CPR. A non-imaging ultrasound probe was manually applied to the neck over the carotid artery to capture CABF during baseline, as verified with diagnostic ultrasound imaging, and during mechanical resuscitation. RESULTS: We successfully collected CABF measurements at baseline in 14/16 swine and during attempted resuscitation with mechanical chest compression in 5/16 swine. Signal characteristics include peak blood flow both towards (90.4 +/-20.4 cm/s) and away from the brain (-44.2 +/-31.8 cm/s) during resuscitation, each larger than flow towards (41.7+/-14.8 cm/s) and away from brain (-3.0 +/-7.8 cm/s) during baseline. CONCLUSION: Measurement of CABF before and during CPR in swine with a non-imaging ultrasound probe is feasible before CA and informative when achieved during CPR. For example, observations of reverse flow within the carotid artery during CPR merits further study for its prevalence and effect on resuscitation outcomes. Also, tissue motion represents a significant obstacle for CABF measurement during CPR. Additional work will determine the feasibility and utility of non-imaging ultrasound measurements of CABF during resuscitation.


Asunto(s)
Reanimación Cardiopulmonar/métodos , Arterias Carótidas/diagnóstico por imagen , Paro Cardíaco/terapia , Ultrasonografía Doppler/métodos , Animales , Velocidad del Flujo Sanguíneo/fisiología , Arterias Carótidas/fisiopatología , Modelos Animales de Enfermedad , Masaje Cardíaco/métodos , Humanos , Proyectos Piloto , Porcinos
9.
Am J Emerg Med ; 36(9): 1631-1634, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-29960660

RESUMEN

BACKGROUND: Incarcerated individuals represent a significant proportion of the US population and face unique healthcare challenges. Scarce articles have been published about emergency department (ED) care of these patients. We studied the ED visits from one urban jail to better describe this population. METHODS: A cohort study design was used, identifying patients who were sent to the ED from a city jail in 2015. Demographics, triage information, length of stay, number of studies, billing codes, diagnoses, and disposition data were collected. These were compared to the overall ED patient population in the same year. RESULTS: 868 ED visits by jail patients occurred, representing 1.3% of the ED census. Compared to the general population, incarcerated patients were younger (32.1 years vs. 44.0 years, p < .01), healthier based on Elixhauser comorbidity scores (0.71 vs. 0.98, p < .01), and had lower admission rates (11.29% vs. 21.54%, p < .01). An abnormal vital sign was noted in 25% of incarcerated patients. Laboratory (61% vs. 57%, p < .02) and radiologic (63% vs 45%, p < .001) testing was more frequent for inmates and length of stay was longer (271 vs. 225 min, p < .01). CONCLUSION: ED visits from jail were common, involving a relatively young and healthy population with a low incidence of abnormal vital signs and admission. Given the high costs associated with ED care and the medical resources available at some jails, further study should evaluate if increased jail medical capabilities could improve care and decrease costs by decreasing ED visits.


Asunto(s)
Servicio de Urgencia en Hospital/estadística & datos numéricos , Aceptación de la Atención de Salud/estadística & datos numéricos , Prisioneros/estadística & datos numéricos , Adulto , Femenino , Humanos , Tiempo de Internación/estadística & datos numéricos , Masculino , Prisiones/estadística & datos numéricos , Población Urbana/estadística & datos numéricos , Washingtón
10.
BMJ Qual Saf ; 26(11): 881-891, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-28866621

RESUMEN

BACKGROUND: A subset of high-risk procedures present significant safety threats due to their (1) infrequent occurrence, (2) execution under time constraints and (3) immediate necessity for patient survival. A Just-in-Time (JIT) intervention could provide real-time bedside guidance to improve high-risk procedural performance and address procedural deficits associated with skill decay. OBJECTIVE: To evaluate the impact of a novel JIT intervention on transvenous pacemaker (TVP) placement during a simulated patient event. METHODS: This was a prospective, randomised controlled study to determine the effect of a JIT intervention on performance of TVP placement. Subjects included board-certified emergency medicine physicians from two hospitals. The JIT intervention consisted of a portable, bedside computer-based procedural adjunct. The primary outcome was performance during a simulated patient encounter requiring TVP placement, as assessed by trained raters using a technical skills checklist. Secondary outcomes included global performance ratings, time to TVP placement, number of critical omissions and System Usability Scale scores (intervention only). RESULTS: Groups were similar at baseline across all outcomes. Compared with the control group, the intervention group demonstrated statistically significant improvement in the technical checklist score (11.45 vs 23.44, p<0.001, Cohen's d effect size 4.64), the global rating scale (2.27 vs 4.54, p<0.001, Cohen's d effect size 3.76), and a statistically significant reduction in critical omissions (2.23 vs 0.68, p<0.001, Cohen's d effect size -1.86). The difference in time to procedural completion was not statistically significant between conditions (11.15 min vs 12.80 min, p=0.12, Cohen's d effect size 0.65). System Usability Scale scores demonstrated excellent usability. CONCLUSION: A JIT intervention improved procedure perfromance, suggesting a role for JIT interventions in rarely performed procedures.


Asunto(s)
Procedimientos Quirúrgicos Cardiovasculares/educación , Competencia Clínica , Medicina de Emergencia/educación , Adulto , Lista de Verificación , Simulación por Computador , Femenino , Humanos , Masculino , Persona de Mediana Edad , Marcapaso Artificial , Estudios Prospectivos , Factores de Tiempo
11.
Crit Care ; 19: 282, 2015 Jul 21.
Artículo en Inglés | MEDLINE | ID: mdl-26325623

RESUMEN

INTRODUCTION: In low-resource settings it is not always possible to acquire the information required to diagnose acute respiratory distress syndrome (ARDS). Ultrasound and pulse oximetry, however, may be available in these settings. This study was designed to test whether pulmonary ultrasound and pulse oximetry could be used in place of traditional radiographic and oxygenation evaluation for ARDS. METHODS: This study was a prospective, single-center study in the ICU of Harborview Medical Center, a referral hospital in Seattle, Washington, USA. Bedside pulmonary ultrasound was performed on ICU patients receiving invasive mechanical ventilation. Pulse oximetric oxygen saturation (SpO2), partial pressure of oxygen (PaO2), fraction of inspired oxygen (FiO2), provider diagnoses, and chest radiograph closest to time of ultrasound were recorded or interpreted. RESULTS: One hundred and twenty three ultrasound assessments were performed on 77 consecutively enrolled patients with respiratory failure. Oxygenation and radiographic criteria for ARDS were met in 35 assessments. Where SpO2 ≤ 97%, the Spearman rank correlation coefficient between SpO2/FiO2 and PaO2/FiO2 was 0.83, p < 0.0001. The sensitivity and specificity of the previously reported threshold of SpO2/FiO2 ≤ 315 for PaO2/FiO2 ≤ 300 was 83% (95% confidence interval (CI) 68-93), and 50% (95% CI 1-99), respectively. Sensitivity and specificity of SpO2/FiO2 ≤ 235 for PaO2/FiO2 ≤ 200 was 70% (95% CI 47-87), and 90% (95% CI 68-99), respectively. For pulmonary ultrasound assessments interpreted by the study physician, the sensitivity and specificity of ultrasound interstitial syndrome bilaterally and involving at least three lung fields were 80% (95% CI 63-92) and 62% (95% CI 49-74) for radiographic criteria for ARDS. Combining SpO2/FiO2 with ultrasound to determine oxygenation and radiographic criteria for ARDS, the sensitivity was 83% (95% CI 52-98) and specificity was 62% (95% CI 38-82). For moderate-severe ARDS criteria (PaO2/FiO2 ≤ 200), sensitivity was 64% (95% CI 31-89) and specificity was 86% (95% CI 65-97). Excluding repeat assessments and independent interpretation of ultrasound images did not significantly alter the sensitivity measures. CONCLUSIONS: Pulse oximetry and pulmonary ultrasound may be useful tools to screen for, or rule out, impaired oxygenation or lung abnormalities consistent with ARDS in under-resourced settings where arterial blood gas testing and chest radiography are not readily available.


Asunto(s)
Análisis de los Gases de la Sangre , Pulmón/diagnóstico por imagen , Oximetría , Síndrome de Dificultad Respiratoria/diagnóstico , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Proyectos Piloto , Estudios Prospectivos , Radiografía Torácica , Reproducibilidad de los Resultados , Síndrome de Dificultad Respiratoria/sangre , Síndrome de Dificultad Respiratoria/diagnóstico por imagen , Sensibilidad y Especificidad , Ultrasonografía
12.
Resuscitation ; 96: 121-5, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26234896

RESUMEN

OBJECTIVE: High quality chest compressions are the cornerstone of effective cardiopulmonary resuscitation (CPR). There is no available method of real time noninvasive hemodynamic measurement and feedback to inform rescuers of the efficacy of compressions. Ultrasound-based measures of blood flow may provide immediate, noninvasive hemodynamic information. Our objective was to determine the feasibility and safety of using ultrasound to measure blood flow on patients with cardiac arrest. METHODS: Study design This was a prospective cohort study in an emergency department setting. Subjects Included were patients receiving ongoing manual chest compressions for cardiac arrest. Excluded were those less than 18 years of age, incarcerated, pregnant, with neck injury, or obvious traumatic cause of arrest. Scan protocol Physicians recorded blood flow over the common carotid arteries during chest compressions with transverse and longitudinal color flow and Doppler using a portable ultrasound machine (CX30, Philips Healthcare., Andover, MA). Measurements Duration of scan time, and the median values for peak systolic (PSV), end-diastolic (EDV) and mean diastolic (MDV) carotid blood flow velocities were captured. Feasibility was defined as the proportion of eligible subjects upon whom ultrasound was initiated Safety was defined as availability of at least 5 min of scanning time. RESULTS: Nineteen patients (56% of eligible) where enrolled and had ultrasound measurements attempted during manual compressions. In one patient, scanning was not initiated because ongoing CPR efforts were terminated. Three patients were enrolled but had no images available for review. A total of 15 patients (78% of attempted) had ultrasound imaging saved. Most (n=10, 66%) had scanning times greater than 5 min (median 5 min 59s, interquartile range 3 min 15s to 8 min 25s), median PSV was 67 cms(-1) (IQR 55-106), median EDV was 18 cms(-1) (IQR 12-27), and median MDV was 14 cms(-1) (IQR 9-18). CONCLUSIONS: Ultrasound measurement of common carotid artery blood flow during CPR is feasible. Further studies are necessary to correlate carotid blood flow to other hemodynamic measures and its effects on patient outcomes.


Asunto(s)
Velocidad del Flujo Sanguíneo/fisiología , Reanimación Cardiopulmonar/métodos , Arterias Carótidas/diagnóstico por imagen , Paro Cardíaco/diagnóstico por imagen , Masaje Cardíaco/métodos , Ultrasonografía Doppler/métodos , Adulto , Anciano , Arterias Carótidas/fisiopatología , Servicio de Urgencia en Hospital , Estudios de Factibilidad , Femenino , Estudios de Seguimiento , Paro Cardíaco/fisiopatología , Paro Cardíaco/terapia , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Reproducibilidad de los Resultados
13.
Crit Ultrasound J ; 7(1): 28, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26123609

RESUMEN

BACKGROUND: Access to ultrasound has increased significantly in resource-limited settings, including the developing world; however, there remains a lack of sonography education and ultrasound-trained physician support in developing countries. To further investigate this potential knowledge gap, our primary objective was to assess perceived barriers to ultrasound use in resource-limited settings by surveying care providers who practice in low- and middle-income settings. METHODS: A 25-question online survey was made available to health care providers who work with an ultrasound machine in low- and middle-income countries (LMICs), including doctors, nurses, technicians, and clinical officers. This was a convenience sample obtained from list-serves of ultrasound and radiologic societies. The survey was analyzed, and descriptive results were obtained. RESULTS: One hundred and thirty-eight respondents representing 44 LMICs including countries from the continents of Africa, South America, and Asia completed the survey, with a response rate of 9.6 %. Ninety-one percent of the respondents were doctors, and 9 % were nurses or other providers. Applications for ultrasound were diverse, including obstetrics (75 %), DVT evaluation (51 %), abscess evaluation (54 %), cardiac evaluation (64 %), inferior vena cava (IVC) assessment (49 %), Focused Assessment Sonography for Trauma (FAST) exam (64 %), biliary tree assessment (54 %), and other applications. The respondents identified the following barriers to use of ultrasound: lack of training (60 %), lack of equipment (45 %), ultrasound machine malfunction (37 %), and lack of ultrasound maintenance capability (47 %). Seventy-four percent of the respondents wished to have further training in ultrasound, and 82 % were open to receiving distance learning or telesonography training. Subjects used communication tools including Skype, Dropbox, emailed photos, and picture archiving and communication system (PACS) as ways to communicate and receive feedback on ultrasound images. CONCLUSIONS: Health care providers in the developing world identify lack of training as a primary barrier to regular use of ultrasound in their practice. While equipment requirements including maintenance and cost of machines are also important factors, future research is warranted on best practices for training methods, including telesonography and distance learning to enhance ultrasound use in low-resource settings.

14.
J Surg Educ ; 72(4): e82-7, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25911457

RESUMEN

OBJECTIVE: Point-of-care ultrasound (POCUS) is a vital tool for diagnosis and management of critically ill patients, particularly in resource-limited settings where access to diagnostic imaging may be constrained. We aimed to develop a novel POCUS training curriculum for surgical practice in the United States and in resource-limited settings in low- and middle-income countries and to determine its effect on surgical resident self-assessments of efficacy and confidence. DESIGN: We conducted an observational cohort study evaluating a POCUS training course that comprised 7 sessions of 2 hours each with didactics and proctored skills stations covering ultrasound applications for trauma (Focused Assessement with Sonography for Trauma (FAST) examination), obstetrics, vascular, soft tissue, regional anesthesia, focused echocardiography, and ultrasound guidance for procedures. Surveys on attitudes, prior experience, and confidence in point-of-care ultrasound applications were conducted before and after the course. SETTING: General Surgery Training Program in Seattle, Washington. PARTICIPANTS: A total of 16 residents participated in the course; 15 and 10 residents completed the precourse and postcourse surveys, respectively. RESULTS: The mean composite confidence score from pretest compared with posttest improved from 23.3 (±10.2) to 37.8 (±6.7). Median confidence scores (1-6 scale) improved from 1.5 to 5.0 in performance of FAST (p < 0.001). Residents reported greater confidence in their ability to identify pericardial (2 to 4, p = 0.009) and peritoneal fluid (2 to 4.5, p < 0.001), to use ultrasound to guide procedures (3.5 to 4.0, p = 0.008), and to estimate ejection fraction (1 to 4, p = 0.004). Both before and after training, surgical residents overwhelmingly agreed with statements that ultrasound would improve their US-based practice, make them a better surgical resident, and improve their practice in resource-limited settings. CONCLUSIONS: After a POCUS course designed specifically for surgeons, surgical residents had improved self-efficacy and confidence levels across a broad range of skills.


Asunto(s)
Cirugía General/educación , Internado y Residencia , Sistemas de Atención de Punto , Ultrasonografía , Salud Global/educación , Resultado del Tratamiento
15.
West J Emerg Med ; 15(6): 636-40, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25247032

RESUMEN

INTRODUCTION: Late obstetric emergencies are time critical presentations in the emergency department. Evaluation to ensure the safety of mother and child includes rapid assessment of fetal viability, fetal heart rate (FHR), fetal lie, and estimated gestational age (EGA). Point-of-care (POC) obstetric ultrasound (OBUS) offers the advantage of being able to provide all these measurements. We studied the impact of POC OBUS training on emergency physician (EP) confidence, knowledge, and OBUS skill performance on a live model. METHODS: This is a prospective observational study evaluating an educational intervention we designed, called the BE-SAFE curriculum (BEdside Sonography for the Assessment of the Fetus in Emergencies). Subjects were a convenience sample of EP attendings (N=17) and residents (N=14). Prior to the educational intervention, participants completed a self-assessment survey on their confidence regarding OBUS, and took a pre-test to assess their baseline knowledge of OBUS. They then completed a 3-hour training session consisting of didactic and hands-on education in OBUS. After training, each subject's time and accuracy of performance of FHR, EGA, and fetal lie was recorded. Post-intervention knowledge tests and confidence surveys were administered. Results were compared with non-parametric t-tests. RESULTS: Pre- and post-test knowledge assessment scores for previously untrained EPs improved from 65.7% [SD=20.8] to 90% [SD=8.2] (p<0.0007). Self-confidence on a scale of 1-6 improved significantly for identification of FHR, fetal lie, and EGA. After training, the average times for completion of OBUS critical skills were as follows: cardiac activity (9s), FHR (68.6s), fetal lie (28.1s), and EGA (158.1 sec). EGA estimates averaged 28w0d (25w0d-30w6d) for the model's true gestational age of 27w0d. CONCLUSION: After a focused POC OBUS training intervention, the BE-SAFE educational intervention, EPs can accurately and rapidly use ultrasound to determine FHR, fetal lie, and estimate gestational age in mid-late pregnancy.


Asunto(s)
Servicio de Urgencia en Hospital , Enfermedades Fetales/diagnóstico por imagen , Obstetricia/educación , Complicaciones del Embarazo/diagnóstico por imagen , Competencia Clínica , Evaluación Educacional , Femenino , Edad Gestacional , Humanos , Obstetricia/instrumentación , Sistemas de Atención de Punto , Embarazo , Tercer Trimestre del Embarazo , Estudios Prospectivos , Ultrasonografía
16.
BMJ Case Rep ; 20132013 Jul 16.
Artículo en Inglés | MEDLINE | ID: mdl-23861276

RESUMEN

Agranulocytosis is a rare yet life-threatening complication of methimazole therapy for hyperthyroidism. We present the case of a 37-year-old female recently started on methimazole for hyperthyroidism who presented to our facility for evaluation of suspected thyroid storm. In addition to having abnormal thyroid indices, she was noted to have an odontogenic abscess, and was septic with profound neutropenia. Her symptoms resolved quickly following incision and drainage of her abscess and treatment with broad-spectrum antibiotics. Her neutrophil count improved significantly following cessation of methimazole and administration of granulocyte colony-stimulating factor. Diagnosis was initially confounded by the similarity between symptoms of early sepsis and those of thyroid storm. This case report discusses the factors leading to diagnostic delay and highlights the dangerous manifestations of neutropenia in patients on methimazole therapy.


Asunto(s)
Agranulocitosis/inducido químicamente , Antitiroideos/efectos adversos , Hipertiroidismo/tratamiento farmacológico , Metimazol/efectos adversos , Sepsis/diagnóstico , Crisis Tiroidea/diagnóstico , Adulto , Diagnóstico Diferencial , Femenino , Humanos
18.
Am J Emerg Med ; 27(9): 1170.e1-2, 2009 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-19931781

RESUMEN

An interstitial pregnancy is a rare type of ectopic pregnancy located within the proximal portion of the fallopian tube in the muscular wall of the uterus. They are more likely to result in significant or fatal hemorrhage because of the increased vascularity. Diagnosis of interstitial pregnancy is challenging but critical to facilitate prompt and appropriate intervention. Ultrasound performed by an emergency physician is commonly used to assess early pregnancy, but little has been published in the emergency medicine literature regarding its use in assessing for presence of interstitial pregnancy. We describe a case of a ruptured interstitial pregnancy diagnosed by emergency ultrasonography in the emergency department and review the literature regarding the sonographic findings of interstitial pregnancies.


Asunto(s)
Embarazo Abdominal/diagnóstico por imagen , Ultrasonografía Prenatal , Rotura Uterina/diagnóstico por imagen , Adulto , Servicio de Urgencia en Hospital , Femenino , Humanos , Embarazo , Embarazo Abdominal/cirugía , Rotura Uterina/cirugía
19.
Emerg Med Clin North Am ; 24(2): 433-48, viii, 2006 May.
Artículo en Inglés | MEDLINE | ID: mdl-16584965

RESUMEN

As life expectancy continues to rise, the number of geriatric patients will increase and the percentages of geriatric patients seen in the emergency department will reflect those numbers. Emergency physicians are responsible for making immediate diagnoses and initiating expeditious treatment. Infectious diseases in the elderly are more prevalent, challenging to diagnose, and are associated with greater morbidity and mortality than with the younger patient population.


Asunto(s)
Enfermedades Transmisibles , Urgencias Médicas/epidemiología , Anciano , Enfermedades Transmisibles/epidemiología , Enfermedades Transmisibles/terapia , Servicio de Urgencia en Hospital/estadística & datos numéricos , Servicios de Salud para Ancianos/estadística & datos numéricos , Humanos , Incidencia , Estados Unidos/epidemiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...