Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 314
Filtrar
1.
Clin Ophthalmol ; 18: 1789-1795, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38919403

RESUMEN

To review the latest surgical advances and evolving clinical use of scleral bio-tissue for reinforcement in the eye and review the published literature on novel surgical applications of scleral allograft bio-tissue. Conventional surgical procedures for scleral reinforcement using homologous scleral allograft have been traditionally ab-externo interventions comprising of anterior or posterior reinforcement of the sclera for clinical indications such as trauma, scleromalacia, glaucoma drainage device coverage, scleral perforation, buckle repair as well as posterior reinforcement for pathologic myopia and staphyloma. There have been a few novel ab-interno uses of scleral bio-tissue for reinforcement in both retina and glaucoma. Over the last decade, there has been an increase in peer-reviewed publications on scleral reinforcement, reflecting more interest in its clinical applications. With favorable biological and biomechanical properties, scleral allograft may be an ideal substrate for an array of new applications and surgical uses.

2.
Ophthalmol Glaucoma ; 2024 Jun 06.
Artículo en Inglés | MEDLINE | ID: mdl-38851392

RESUMEN

PURPOSE: To compare the effectiveness and adverse event profile of standalone SIBS microshunt implantation with adjunct MMC 0.2 mg/ml and MMC 0.4 mg/ml. DESIGN: Mega-analysis using individual patient data from international prospective and retrospective clinical studies. STUDY POPULATION: Patients with glaucoma who underwent implantation of a SIBS microshunt with MMC as a standalone procedure. METHODS: A comparison of eyes that received MMC 0.2 mg/ml or 0.4 mg/ml MAIN OUTCOMES MEASURES: Primary outcome was complete success defined as the proportion of eyes at one year with all of the following: (1) no two consecutive IOPs > 17 mmHg; (2) no clinical hypotony (3) ≥20% IOP reduction from baseline and (4) no use of glaucoma medications. Secondary outcomes included IOP thresholds of 12 mmHg,14 mm Hg and 21mmHg, median IOP, number of medications, risk factors for failure, interventions, adverse events, and reoperations. RESULTS: At 1 year, the complete success rate was significantly higher (71.3% vs 50.46%, p<0.001) and the median IOP significantly lower (13.0 vs. 14.2 mmHg, p<0.05) in the MMC 0.4 mg/ml group. MMC 0.2 mg/ml was found to be a significant risk factor for failure (HR 1.75 95%CI 1.14 to 2.67). Needling and surgical revision occurred at a lower rate in the MMC 0.4 mg/ml group (7% vs. 18.8%, p= 0.002 and 4.3% vs.13.7% p= 0.0087, respectively). Adverse events occurred at a similar frequency in both groups (26.6% MMC 0.2 mg/ml vs. 29.6% MMC 0.4 mg/ml, p=0.46), most of which were early and transient. CONCLUSION: SIBS microshunt implantation with MMC 0.4 mg/ml resulted in a higher success rate with greater IOP reduction compared to MMC 0.2 mg/ml. Higher MMC concentration was not associated with increased serious adverse events.

3.
Invest Ophthalmol Vis Sci ; 65(5): 13, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38713484

RESUMEN

Purpose: The purpose of this study was to measure intraocular pressure (IOP) elevation while applying standard gonioscopy, selective laser trabeculoplasty (SLT), and laser iridotomy procedural lenses. Methods: Twelve cadaver eyes were mounted to a custom apparatus and cannulated with a pressure transducer which measured IOP. The apparatus was mounted to a load cell which measured the force on the eye. Six ophthalmologists performed simulated gonioscopy (Sussman 4 mirror lens), SLT (Latina lens), and laser iridotomy (Abraham lens) while a computer recorded IOP (mm Hg) and force (grams). The main outcome measures were IOP and force applied to the eye globe during ophthalmic diagnostics and procedures. Results: The average IOP's during gonioscopy, SLT, and laser iridotomy were 43.2 ± 16.9 mm Hg, 39.8 ± 9.9 mm Hg, and 42.7 ± 12.6 mm Hg, respectively. The mean force on the eye for the Sussman, Latina, and Abraham lens was 40.3 ± 26.4 grams, 66.7 ± 29.8 grams, and 65.5 ± 35.9 grams, respectively. The average force applied to the eye by the Sussman lens was significantly lower than both the Latina lens (P = 0.0008) and the Abraham lens (P = 0.001). During gonioscopy indentation, IOP elevated on average to 80.5 ± 22.6 mm Hg. During simulated laser iridotomy tamponade, IOP elevated on average to 82.3 ± 27.2 mm Hg. Conclusions: In cadaver eyes, the use of standard ophthalmic procedural lenses elevated IOP by approximately 20 mm Hg above baseline.


Asunto(s)
Cadáver , Gonioscopía , Presión Intraocular , Iris , Terapia por Láser , Trabeculectomía , Humanos , Presión Intraocular/fisiología , Terapia por Láser/métodos , Iris/cirugía , Trabeculectomía/métodos , Tonometría Ocular , Anciano , Iridectomía/métodos , Femenino , Masculino , Anciano de 80 o más Años
4.
BMJ Open Ophthalmol ; 9(1)2024 May 09.
Artículo en Inglés | MEDLINE | ID: mdl-38729627

RESUMEN

PURPOSE: Risk communication is an integral aspect of shared decision-making and evidence-based patient choice. There is currently no recommended way of communicating risks and benefits of cataract surgery to patients. This study aims to investigate whether the way this information is presented influences patients' perception of how risky surgery will be. METHODS AND ANALYSIS: Two-arm parallel randomised study and patients referred for cataract surgery were assigned to receive information framed either positively (99% chance of no adverse effects) or negatively (1% chance of adverse effects). Subsequently, patients rated their perceived risk of experiencing surgical side effects on a 1-6 scale. RESULTS: This study included 100 patients, 50 in each study group. Median (IQR) risk perception was 2 (1-2) in the positive framing group and 3 (1-3) in the negative framing group (p<0.0001). Risk framing was the only factor that was significant in risk perception, with no differences found by other patient clinical or demographic characteristics. CONCLUSION: Patients who received positive framing reported lower risk scores for cataract surgery than patients who received negative framing. Patient factors were not identified as significant determinants in patients' perceived risk. Larger longitudinal studies are warranted to further investigate.


Asunto(s)
Extracción de Catarata , Comunicación , Humanos , Masculino , Femenino , Anciano , Medición de Riesgo , Persona de Mediana Edad , Encuestas y Cuestionarios , Anciano de 80 o más Años , Educación del Paciente como Asunto
5.
Transl Vis Sci Technol ; 13(3): 10, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38488433

RESUMEN

Purpose: Compare estimated sensitivities of SITA-Standard to the RATA-Standard algorithm of the Radius virtual reality perimeter (VRP), and measure concordance in glaucoma staging. Methods: One hundred adult glaucoma patients-half with suspect or mild glaucoma, and half with moderate or severe-from five clinics performed four 24-2 visual field tests during a single visit, two with the Humphrey Field Analyzer (HFA) and two with Radius, in randomized order: HRHR or RHRH. Only one eye was tested per participant. We used the Wilcoxon rank sum test with Bonferroni correction to compare distributions of estimated sensitivities across all 54 test locations over the 15 to 40 dB measurement range of the Radius. Weighted kappa measured concordance in glaucoma staging between two masked glaucoma experts using Medicare definitions of severity. Results: A total of 62 OD and 38 OS eyes were tested. Estimated sensitivities for SITA-Standard and RATA-Standard were not significantly different for OD, but were for OS-likely because of SITA-Standard OD and OS being significantly different in our sample, but not for RATA-Standard. Low agreement was observed between 15 to 22 dB. Concordance in glaucoma staging was high for both graders: kappa = 0.91 and kappa = 0.93. Average test duration was 298 seconds for RATA-Standard and 341 seconds for SITA-Standard. The correlation in mean deviation was 0.94. Conclusions: Estimated sensitivities of RATA-Standard are comparable to SITA-Standard between 23 to 40 dB with high concordance in glaucoma staging. Translational Relevance: Radius VRP is statistically noninferior to HFA when staging glaucoma using Medicare definitions.


Asunto(s)
Glaucoma , Realidad Virtual , Dispositivos Electrónicos Vestibles , Anciano , Estados Unidos , Adulto , Humanos , Campos Visuales , Trastornos de la Visión , Reproducibilidad de los Resultados , Medicare , Glaucoma/diagnóstico , Pruebas del Campo Visual/métodos
6.
BMC Ophthalmol ; 24(1): 122, 2024 Mar 18.
Artículo en Inglés | MEDLINE | ID: mdl-38494493

RESUMEN

BACKGROUND: To evaluate the safety and efficacy of the Minimally Invasive Micro Sclerotomy (MIMS) procedure in the management of uncontrolled open-angle glaucoma. METHODS: A prospective, open-label, single-arm clinical evaluation with intra-subject comparisons performed at the Ophthalmologic Center after S.V. Malayan, Yerevan, Armenia. Included were adults with primary open-angle glaucoma (OAG) (N = 114) or exfoliative glaucoma (N = 6) who were uncontrolled (IOP > 21) on tolerated topical medication. Mild (N = 7), moderate (N = 66) and severe (n = 47) cases were prospectively included without preselection. Following subconjunctival Mitomycin C, an ab-interno MIMS procedure was performed alone (N = 100) or combined with phacoemulsification (N = 20). Patients were followed for 52 weeks. Procedure-related complications and adverse events were recorded. Success criteria were defined as -5 < IOP ≤ 21mmHg OR a reduction in IOP of ≥ 20% from baseline with (qualified success) or without (complete success) hypotensive medications. RESULTS: Mean patient age was 69 ± 10.1 years. The mean duration of the procedure was 2:01 ± 0:41 min:sec. Scleral drainage channels were achieved in all cases. No device malfunctions, intraoperative complications, or serious adverse events were reported. Iris plugging of the sclerostomy site and early spikes in IOP were the most common adverse events. The only reason for failure was final IOP > 21 mmHg on tolerated medication. At 52 weeks (n = 93), mean IOP decreased by 38% from baseline (P < 0.001), from 27.9 ± 3.7 to 17.5 ± 5.3 mmHg, a difference of 10.5 mmHg (95% CI: -11.7, -9.3). One-year qualified success was documented in 82.1% (95% CI: 72.9%,89.2%) of the patients and complete success, in 70.5% (60.3-79.4%). 60% (95 CI:49.4%,69.9%) of the patients achieved maximum IOP level of 14 mmHg or at least 30% reduction in IOP. CONCLUSIONS: MIMS procedure is a relatively simple, short and safe minimally invasive bleb-forming procedure. Its efficacy, as found in this short-term evaluation, lends it suitable for mild and moderate uncontrolled open-angle glaucoma patients. TRIAL REGISTRATION: ClinicalTrials.gov ID: NCT04503590 2019-05-29.


Asunto(s)
Glaucoma de Ángulo Abierto , Esclerostomía , Adulto , Anciano , Humanos , Persona de Mediana Edad , Glaucoma de Ángulo Abierto/cirugía , Glaucoma de Ángulo Abierto/tratamiento farmacológico , Presión Intraocular , Estudios Prospectivos , Esclerótica/cirugía , Esclerostomía/métodos , Resultado del Tratamiento
7.
Eye (Lond) ; 38(8): 1518-1528, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38326483

RESUMEN

BACKGROUND: To investigate the effect of perioperative intraocular pressure (IOP) lowering medications on controlling postoperative IOP following uncomplicated phacoemulsification. METHODS: Ovid MEDLINE, EMBASE, and Cochrane CENTRAL databases were searched up until November 2022. Randomised controlled trials (RCTs) that assessed IOP change via applanation tonometry in medicated and control arms following uncomplicated cataract surgery in healthy eyes were included. The primary outcome was the weighted mean difference (WMD) of IOP at 2-8 h, 12-24 h, and 1-7 days postoperatively within each medication class or common fixed-combination formulations. Risk of bias was assessed using the revised risk of bias in randomised trials (RoB-2). Level of evidence was rated using the Grading of Recommendation, Assessment, Development and Evaluation (GRADE) RESULTS: From 702 screened articles, 30 RCTs involving 2986 eyes were included. There was a statistically significant reduction in IOP favouring treatment arms at 2-8 h (WMD = -3.87 mmHg; 95% CI [-4.75, -3.00]; p < 0.001) and 12-24 h (WMD = -2.69 mmHg; 95% CI [-3.36, -2.02]; p < 0.001), with the effect wearing off beyond 1 day (p = 0.18). Between medication classes, the largest effect at both 2-8 h and 12-24 h was observed with intracameral cholinergics or fixed-combination carbonic anhydrase inhibitor-beta-blocker (FCCB) formulations. Conversely, the smallest effect was observed with prostaglandin analogues, alpha-agonists, and topical carbonic anhydrase inhibitors (CAIs). CONCLUSION: Prophylaxis against acute IOP elevations following uncomplicated cataract surgery is effective. FCCB and intracameral cholinergics are the most effective ocular antihypertensive agents, while alpha-agonists, prostaglandin analogues, and topical CAIs were found to be the least effective. These findings may inform future surgical guidelines.


Asunto(s)
Antihipertensivos , Presión Intraocular , Facoemulsificación , Humanos , Presión Intraocular/efectos de los fármacos , Presión Intraocular/fisiología , Antihipertensivos/uso terapéutico , Complicaciones Posoperatorias/prevención & control , Tonometría Ocular , Hipertensión Ocular/prevención & control
8.
Am J Ophthalmol ; 263: 81-92, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38387827

RESUMEN

PURPOSE: To investigate the association between social determinants of health (SDH) in the domains of social and community context, education access, environmental context, economic stability, and healthcare access, with glaucoma prevalence. DESIGN: Cross-sectional study. METHODS: The study population consisted of adult participants who answered glaucoma-related questions on the 2017 National Health Interview Survey (NHIS), the most recent iteration that includes glaucoma-related questions. The main outcome measures included the relationships between SDH-related factors and self-reported glaucoma diagnosis as well as self-reported glaucomatous vision loss were examined using univariable and multivariable regression models. RESULTS: In total, 26,696 of 26,742 (99.83%) NHIS respondents were included, of whom 880 (3.30%) reported a glaucoma diagnosis and 275 (1.03%) reported glaucomatous vision loss. Participants were predominantly middle-aged (50.95 ± 18.60 years), female (54.75%), and non-Hispanic White (70.49%). In age-adjusted multivariable regression (n = 25,456), non-Hispanic Black race (odds ratio [OR] = 1.87, 99% CI = [1.37, 2.55], P < .001, compared to non-Hispanic White race) and poor health status (OR = 1.54, 99% CI = [1.00, 2.37], P = .01, compared to good health status) were significant predictors of glaucoma diagnosis. For glaucomatous vision loss, having an income below the poverty threshold (OR = 2.41, 99% CI = [1.12, 5.20], P = .003, compared to income ≥5 times the poverty threshold) was the only significant predictor in univariable analyses. No SDH-related factors were significantly associated with glaucomatous vision loss in multivariable analysis (n = 848). Multicollinearity was minimal (variation inflation factor<1.6 for all independent variables). CONCLUSIONS: Non-Hispanic Black race and poor health status were associated with self-reported glaucoma diagnosis. Physicians and policymakers may consider SDH when assessing clinical risk and designing public health interventions.


Asunto(s)
Glaucoma , Encuestas Epidemiológicas , Autoinforme , Humanos , Masculino , Femenino , Estudios Transversales , Persona de Mediana Edad , Glaucoma/epidemiología , Glaucoma/diagnóstico , Estados Unidos/epidemiología , Anciano , Adulto , Prevalencia , Factores Sociodemográficos , Determinantes Sociales de la Salud , Factores de Riesgo , Adulto Joven
9.
J Cataract Refract Surg ; 50(3): 306-311, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38381619

RESUMEN

A 78-year-old woman with an ocular history of cataract surgery with a diffractive intraocular lens (IOL) in each eye has developed fluctuating vision, greater in the right eye than the left eye, after 4 years. She has a history of inactive central serous retinopathy and a vision potential of 20/25 + 2 in the right eye and 20/25 in the left eye. She has well-controlled diabetes, hypertension, and hypercholesterolemia. She has enjoyed her spectacle independence for some time and wishes to have her vision restored. On examination, her uncorrected distance visual acuity (UDVA) was 20/50 in the right eye and 20/25 in the left eye and her uncorrected near visual acuity (UNVA) was J3 in the right eye and J1 in the left eye. Intraocular pressures (IOPs) measured 22 mm Hg in the right eye and 18 mm Hg in the left eye. Pupils had limited reactivity with irregularity in the right eye but no obvious relative afferent pupillary defect. Motility and confrontation visual fields were unremarkable in both eyes. Retinal acuity meter was 20/20 in both eyes, and manifest refraction was plano -1.25 × 105 20/40, J3 in the right eye and +0.50 × 20/25, J1 in the left eye. Pertinent findings on slitlamp examination included temporal iris atrophy and transillumination defects greater in the right eye than the left eye, peripupillary pseudoexfoliative changes in both eyes, significant inferior subluxation of a diffractive 3-piece posterior chamber IOL in the capsular bag with lens-pitting peripherally and few central, moderate pseudophacodonesis, and an open posterior capsule in the right eye. In the left eye, she had mild inferior subluxation of a single-piece acrylic diffractive IOL in the capsular bag with moderate pseudophacodonesis and an open posterior capsule (Figure 1JOURNAL/jcrs/04.03/02158034-202403000-00019/figure1/v/2024-02-20T193212Z/r/image-tiff). All other anterior segment findings were unremarkable. On dilated posterior examination, she had a cup-to-disc ratio of 0.50 in the right eye and 0.65 in the left eye without edema hemorrhage or pallor. There were attenuated vessels in both eyes, posterior vitreous detachment in both eyes, and a few small drusen peripherally in both eyes. There was retinal pigment epithelium irregularity and dropout parafoveal in the right eye and subfoveal in the left eye (Figure 2). There was no evidence of macular edema, subretinal fluid, choroidal thickening, or neovascular membranes. The periphery was unremarkable in both eyes.JOURNAL/jcrs/04.03/02158034-202403000-00019/figure2/v/2024-02-20T193212Z/r/image-tiff What testing would you obtain preoperatively to help guide your decision-making? How would you counsel the patient regarding comorbid conditions and expectations?


Asunto(s)
Extracción de Catarata , Lentes Intraoculares , Humanos , Femenino , Anciano , Implantación de Lentes Intraoculares , Motivación , Agudeza Visual
10.
Br J Ophthalmol ; 108(2): 217-222, 2024 01 29.
Artículo en Inglés | MEDLINE | ID: mdl-36593090

RESUMEN

BACKGROUND/AIMS: To report a first-in-human trial in open-angle glaucoma (OAG) subjects treated with a new microinterventional biostent-reinforced cyclodialysis technique to enhance supraciliary aqueous drainage. METHODS: Subjects (N=10; 74.1±7.9 years old) with OAG and cataracts underwent combined phacoemulsification cataract surgery with implantation of a permanent endoscleral supraciliary biostent to reinforce a controlled cyclodialysis cleft. The biostent comprised decellularised scleral allograft tissue microtrephined into a polymer tubular implant intraoperative/postoperative safety, intraocular pressure (IOP) and glaucoma medications were tracked through 12 months postimplantation. RESULTS: Baseline medicated IOP averaged 24.2±6.9 mm Hg with subjects using 1.3±0.8 IOP-lowering medications. Successful biostent implantation was achieved in all individuals without significant complications. Immediate IOP lowering was sustained through 1 year. Twelve-month mean IOP was reduced 40% from baseline to 14.6±3.2 mm Hg (p=0.004; paired two-tailed t-test), and 80% of patients achieved >20% IOP reduction. Biostenting reduced glaucoma medication use 62%, from a baseline mean of 1.3 required medications to 0.5 medications (p=0.037) at postoperative 12 months. The biotissue implant was well tolerated and demonstrated good endothelial safety with only 11% endothelial cell loss at 12 months after combined phaco-biostenting surgery, similar to that expected after phacoemulsification alone. Mean BCVA increased from baseline 20/130 Snellen to 20/36 at postoperative 12 months (p=0.001). CONCLUSION: Supraciliary biostenting in OAG patients is well tolerated, has a good safety profile and produces long-term IOP-lowering while reducing glaucoma medication requirements.


Asunto(s)
Extracción de Catarata , Implantes de Drenaje de Glaucoma , Glaucoma de Ángulo Abierto , Glaucoma , Facoemulsificación , Anciano , Anciano de 80 o más Años , Humanos , Extracción de Catarata/métodos , Glaucoma/cirugía , Glaucoma de Ángulo Abierto/tratamiento farmacológico , Presión Intraocular , Facoemulsificación/métodos , Stents , Resultado del Tratamiento
12.
J Cataract Refract Surg ; 50(4): 369-377, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-37988037

RESUMEN

PURPOSE: To compare 5-year corneal endothelial safety of 3 minimally invasive glaucoma surgery (MIGS) devices (iStent inject , Hydrus Microstent, CyPass Micro-Stent). SETTING: U.S. multicenter trials. DESIGN: Post hoc 5-year analysis from prospective randomized single-masked pivotal trials. METHODS: Mild to moderate open-angle glaucoma subjects received a MIGS implant with phacoemulsification (implant + phaco) or phaco alone (control). In addition, 5-year end points comparing the implant and control groups included proportion of eyes with significant endothelial cell loss (ECL) (>30% or ≥30% vs baseline) and mean endothelial cell density (ECD). RESULTS: Comparable proportions of eyes in the iStent inject + phaco and control groups had significant 60-month ECL (9.4% vs 6.3%, respectively, diff: 3.2%, 95% CI, -5.0% to 11.3%, P = .77). Hydrus (20.8% vs 10.6%, diff: 10.2%, 95% CI, 3.2% to 17.2%, P = .01) and CyPass (27.2% vs 10.0%, diff: 17.2%, 95% CI, 5.6% to 28.7%, P = .02) had more eyes with ECL vs controls (iStent inject 1.49X, Hydrus 1.96X, CyPass 2.72X vs controls). Mean ECD over 60 months for iStent inject was indistinguishable vs control, whereas greater ECL was observed primarily 3 months postoperative (Hydrus) or accelerated after 2 years (CyPass). No iStent inject or Hydrus subjects developed persistent corneal edema, whereas 7 CyPass-implanted eyes developed ECL-related complications. CONCLUSIONS: Through 5 years postoperative, there were no differences in proportion of eyes with significant ECL or mean ECD between the iStent inject and control groups. There was greater 5-year ECL and lower ECD in the Hydrus and CyPass groups vs controls. The Hydrus ECL rate mirrored control after 3 months; the CyPass ECL rate accelerated vs control.


Asunto(s)
Extracción de Catarata , Glaucoma de Ángulo Abierto , Glaucoma , Facoemulsificación , Humanos , Glaucoma de Ángulo Abierto/cirugía , Estudios Prospectivos , Glaucoma/cirugía , Stents , Presión Intraocular
13.
Ophthalmol Sci ; 4(1): 100349, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-37869021

RESUMEN

Objective: In a world where digital media is deeply engrained into our everyday lives, there lies an opportunity to leverage interactions with technology for health and wellness. The Vision Performance Index (VPI) leverages natural human-technology interaction to evaluate visual function using visual, cognitive, and motor psychometric data over 5 domains: field of view, accuracy, multitracking, endurance, and detection. The purpose of this study was to describe a novel method of evaluating holistic visual function through video game-derived VPI score data in patients with specific ocular pathology. Design: Prospective comparative analysis. Participants: Patients with dry eye, glaucoma, cataract, diabetic retinopathy (DR), age-related macular degeneration, and healthy individuals. Methods: The Vizzario Inc software development kit was integrated into 2 video game applications, Balloon Pop and Picture Perfect, which allowed for generation of VPI scores. Study participants were instructed to play rounds of each video game, from which a VPI score was compiled. Main Outcome Measures: The primary outcome was VPI overall score in each comparison group. Vision Performance Index component, subcomponent scores, and psychophysical inputs were also compared. Results: Vision Performance Index scores were generated from 93 patients with macular degeneration (n = 10), cataract (n = 10), DR (n = 15), dry eye (n = 15), glaucoma (n = 16), and no ocular disease (n = 27). The VPI overall score was not significantly different across comparison groups. The VPI subcomponent "reaction accuracy" score was significantly greater in DR patients (106 ± 13.2) versus controls (96.9 ± 11.5), P = 0.0220. The VPI subcomponent "color detection" score was significantly lower in patients with DR (96.8 ± 2.5; p=0.0217) and glaucoma (98.5 ± 6.3; P = 0.0093) compared with controls (101 ± 11). Psychophysical measures were statistically significantly different from controls: proportion correct (lower in DR, age-related macular degeneration), contrast errors (higher in cataract, DR), and saturation errors (higher in dry eye). Conclusions: Vision Performance Index scores can be generated from interactions of an ocular disease population with video games. The VPI may offer utility in monitoring select ocular diseases through evaluation of subcomponent and psychophysical input scores; however, future larger-scale studies must evaluate the validity of this tool. Financial Disclosures: Proprietary or commercial disclosure may be found after the references.

14.
J Cataract Refract Surg ; 50(1): 97-103, 2024 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-38133650

RESUMEN

A 70-year-old man had progressive and severe glaucoma in each eye. He was intolerant to dorzolamide, brimonidine, and netarsudil. Each eye had prior selective laser trabeculoplasty (SLT) as well as phacoemulsification plus minimally invasive glaucoma surgery (MIGS) 6 years before current presentation (iStent [Glaukos Corp.] in the right eye and Cypass [Alcon Laboratories, Inc.] in the left eye). Postoperative acuities were 20/20 and 20/25 in the right and left eyes, respectively. When his left eye progressed with loss of central acuity despite peak intraocular pressures (IOPs) in the middle to upper teens, neuro-ophthalmology consultation was obtained (Figure 1JOURNAL/jcrs/04.03/02158034-202401000-00017/figure1/v/2023-12-22T124801Z/r/image-tiff). That workup included magnetic resonance imaging scan and hematologic screening, but all results were negative, and the neuro-ophthalmic consultant concluded that the vision loss was likely on the basis of glaucoma. Accordingly, a trabeculectomy was performed in the left eye achieving consistent IOPs in the range of 7 to 10 mm Hg without medications, rending the left eye stable since the filtration surgery nearly 2 years previously. The right eye continued to progress both subjectively and objectively, and on recent examination, the IOP measured 20 mm Hg and 09 mm Hg in the right and left eyes, respectively (Figure 2JOURNAL/jcrs/04.03/02158034-202401000-00017/figure2/v/2023-12-22T124801Z/r/image-tiff). Medications included timolol and latanoprostene bunod in the right eye only. Central corneal thickness was 526 µm and 527 µm in the right and left eyes, respectively. The visual acuity now measured 20/25 in the right eye and 20/250 in the left eye. The vertical cup-to-disc ratio was 0.9 in the right eye and 1.0 in the left eye. Gonioscopy revealed a wide open angle in each eye with a patent sclerostomy superiorly in the left eye. The conjunctiva and sclera were healthy and without scarring in the right eye. The bleb in the left eye was diffuse, lightly vascularized, and seidel negative. Axial length (AL) was 26.88 µm in the right eye and 26.77 µm in the left eye. The patient was in good health and was not anticoagulated. An extensive discussion ensued about the best course of action for the right eye. How would you proceed in managing definite progression in this individual's right eye, knowing that he had lost fixation in his left eye at similar pressures?


Asunto(s)
Glaucoma , Trabeculectomía , Masculino , Humanos , Adolescente , Anciano , Glaucoma/cirugía , Trabeculectomía/métodos , Presión Intraocular , Ojo , Timolol
15.
Am J Ophthalmol ; 260: 172-181, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38109951

RESUMEN

PURPOSE: To evaluate the performance and safety of minimally invasive glaucoma surgery with a supraciliary drainage device (MINIject; iSTAR Medical, Wavre, Belgium) in primary open-angle glaucoma (POAG) as a stand-alone procedure. DESIGN: Meta-analysis. METHODS: At 11 sites in Colombia, France, Germany, India, Panama, and Spain, 82 patients were treated in 3 prospective, multicenter, interventional, nonrandomized trials (STAR-I, II, III). Data were pooled in a meta-analysis of up to 2 years of follow-up postimplantation. The main outcome measures were mean relative and absolute reduction in diurnal intraocular pressure (IOP) compared to baseline. Secondary outcomes included patients with IOP ≤18 mmHg, patients with IOP reduction ≥20%, number of IOP-lowering medications, adverse events, and endothelial cell density loss. RESULTS: At the 2-year follow-up (n = 66), mean IOP was reduced from 23.8 ± 3.3 mmHg at baseline to 14.4 ± 4.5 mmHg (-39.3%; P < 0.0001). An IOP reduction of ≥20% was achieved in 89.4% of patients, with 84.8% having an IOP ≤18 mmHg. IOP-lowering medications were reduced from a mean of 2.4 ± 1.1 to 1.4 ± 1.4 (P < 0.0001), with 37.9% of patients being medication-free at 2 years. Mean endothelial cell density loss at 2 years was 6.2 ± 9.1% compared to baseline and no patient had a loss >30%. CONCLUSIONS: This meta-analysis demonstrates the favorable safety and efficacy profile of a supraciliary device implanted in a stand-alone, ab-interno procedure in patients with mild-to-moderate POAG. The data demonstrate that MINIject is a safe and effective, bleb-free treatment option for patients requiring low target IOP up to 2 years.


Asunto(s)
Implantes de Drenaje de Glaucoma , Glaucoma de Ángulo Abierto , Humanos , Estudios Prospectivos , Glaucoma de Ángulo Abierto/cirugía , Glaucoma de Ángulo Abierto/tratamiento farmacológico , Presión Intraocular , Tonometría Ocular , Resultado del Tratamiento , Estudios Multicéntricos como Asunto
16.
Orthod Craniofac Res ; 2023 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-38037851

RESUMEN

INTRODUCTION: Obesity and craniofacial structures are aetiologies of obstructive sleep apnoea (OSA). The effect of obesity onset on the craniofacial development and growth of obese OSA subjects has been suggested, but supporting data were lacking. This study aimed to assess the craniofacial features of adult obese OSA patients in relation to their obesity onset. MATERIALS AND METHODS: A total of 62 adult OSA patients were included in the study, consisting of 12 early-onset (i.e. before puberty), 21 late-onset (i.e. after puberty) and 29 non-obese. All participants underwent a sleep study and cephalometric radiograph. Cephalometric analysis was conducted to measure the craniofacial features among the groups. RESULTS: The early obesity onset group (n = 12) showed a more prognathic mandible, longer lower facial height, protrusive incisors, a more caudal position of the hyoid bone and a wider lower airway. The late-onset group (n = 21) had more proclined and protrusive upper incisors, a shallower overbite, a more inferiorly positioned hyoid bone and an obtuse craniocervical angle. The overall obese group showed a combination of the findings above, plus a shorter soft palate and shorter airway length. There was no significant difference between early and late obesity onset groups. However, the early group showed a tendency for a shallower or decreased mandibular plane angle and deeper overbite. CONCLUSIONS: The current pilot study had many limitations but holds important information as a hypothesis generator. Craniofacial features of OSA patients with different obesity onset showed discrepancies and were distinguished from non-obese controls. Adult OSA patients with an early obesity onset showed a tendency for a more hypodivergent growth pattern than those with a late obesity onset.

17.
AMA J Ethics ; 25(10): E771-776, 2023 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-37801062

RESUMEN

International medical graduates (IMGs) tend to choose careers in geriatric psychiatry likely because high-quality training and robust mentorship opportunities from other IMGs are available. Geriatric psychiatry offers stable career prospects and opportunities to express humanitarian impulses by working closely with elders. IMGs currently constitute almost a quarter of the psychiatry workforce and approximately 53% of the geriatric psychiatry work force in the United States. However, the number of IMGs entering psychiatry residencies-and, subsequently, geriatric psychiatry fellowships-has recently declined. Overreliance on IMGs in the US geriatric psychiatric workforce means these shortages will further burden an already-limited geriatric mental health care workforce and further compromise US health system capacity to meet its elders' needs.


Asunto(s)
Internado y Residencia , Médicos , Psiquiatría , Humanos , Estados Unidos , Anciano , Médicos Graduados Extranjeros , Recursos Humanos , Psiquiatría/educación , Personal de Salud/educación
18.
Clin Ophthalmol ; 17: 2575-2588, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37674591

RESUMEN

Purpose: To evaluate the safety and efficacy of a preservative-free latanoprost 0.005% formulation (T2345) in patients with primary open-angle glaucoma (POAG) or ocular hypertension (OHT) compared to benzalkonium chloride-preserved latanoprost 0.005% (BPL) formulation in the United States (US). Patients and Methods: A prospective, randomized, multicenter, observer-masked, parallel-group study enrolled 335 patients diagnosed with POAG or OHT from 31 US sites who had adequately controlled intraocular pressure (IOP; ≤18 mm Hg) with latanoprost monotherapy. After a ≥72-hour washout period, patients were randomized to T2345 (n=165) or BPL (n=170) groups. Study drugs were dosed once-daily from Day 0 to Day 84 in one or both eyes. The study eye was the eye with lower IOP at baseline. The primary efficacy measure was the between-group comparison of the mean IOP values in the study eye at each time point (8 AM, 10 AM, and 4 PM on Days 15, 42, and 84). Safety measurements included ocular and systemic treatment-emergent adverse events (TEAEs). Results: Both T2345 and BPL adequately controlled IOP with 95% CIs within 1.5 mm Hg in the study eye at all assessed time points. The percentages of patients with diurnal IOP <18 mm Hg at Day 84 were 73.1% vs 78.7% for the T2345 and BPL groups, respectively. Adverse events were generally mild-to-moderate and primarily ocular. Fewer patients in the T2345 group experienced ocular TEAEs (13.9% vs 22.5%, respectively) and TEAEs with a suspected relationship to the study medication compared with the BPL group (5.5% vs 11.8%, respectively). The most common ocular TEAEs were instillation site pain and conjunctival hyperemia. Conclusion: In patients with POAG or OHT, both T2345 and BPL maintained IOP at or below clinically meaningful values for the duration of the study. T2345 showed a favorable safety profile, with numerically lower incidences of ocular TEAEs than BPL.

19.
Carbohydr Polym ; 321: 121318, 2023 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-37739510

RESUMEN

The attention to polymer-based biomaterials, for instance, chitosan and its derivatives, as well as the techniques for using them in numerous scientific domains, is continuously rising. Chitosan is a decomposable naturally occurring polymeric material that is mostly obtained from seafood waste. Because of its special ecofriendly, biocompatible, non- toxic nature as well as antimicrobial properties, chitosan-based materials have received a lot of interest in the field of biomedical applications. The reactivity of chitosan is mainly because of the amino and hydroxyl groups in its composition, which makes it further fascinating for various uses, including biosensing, textile finishing, antimicrobial wound dressing, tissue engineering, bioimaging, gene, DNA and drug delivery and as a coating material for medical implants. This study is an overview of the different types of chitosan-based materials which now a days have been fabricated by applying different techniques and modifications that include etherification, esterification, crosslinking, graft copolymerization and o-acetylation etc. for hydroxyl groups' processes and acetylation, quaternization, Schiff's base reaction, and grafting for amino groups' reactions. Furthermore, this overview summarizes the literature from recent years related to the important applications of chitosan-based materials (i.e., thin films, nanocomposites or nanoparticles, sponges and hydrogels) in different biomedical applications.


Asunto(s)
Quitosano , Esterificación , Materiales Biocompatibles/farmacología , Acetilación , Vendajes , Polímeros
20.
Clin Ophthalmol ; 17: 2483-2492, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37637970

RESUMEN

Microinvasive glaucoma surgery (MIGS) has emerged as a safer method to lower IOP with minimal impact on patient quality of life compared to traditional glaucoma surgeries. With the advent of MIGS, there has been a renewed interest in exploring the suprachoroidal route. MIGS targeting the suprachoroidal space allow for a safe reduction in IOP while sparing conjunctiva and allowing "blebless" surgery, thus avoiding bleb-related complications. This article aims to review the rationale behind the suprachoroidal MIGS procedures and the literature surrounding the efficacy and safety of a novel suprachoroidal device, the MINIject. The available literature has shown promising IOP lowering results with the MINIject implant with a potentially safer and less invasive approach than traditional glaucoma surgeries.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...