Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
2.
Sci Rep ; 14(1): 10719, 2024 05 10.
Artículo en Inglés | MEDLINE | ID: mdl-38729975

RESUMEN

The shielding parameters can vary depending on the geometrical structure of the linear accelerators (LINAC), treatment techniques, and beam energies. Recently, the introduction of O-ring type linear accelerators is increasing. The objective of this study is to evaluate the shielding parameters of new type of linac using a dedicated program developed by us named ORSE (O-ring type Radiation therapy equipment Shielding Evaluation). The shielding evaluation was conducted for a total of four treatment rooms including Elekta Unity, Varian Halcyon, and Accuray Tomotherapy. The developed program possesses the capability to calculate transmitted dose, maximum treatable patient capacity, and shielding wall thickness based on patient data. The doses were measured for five days using glass dosimeters to compare with the results of program. The IMRT factors and use factors obtained from patient data showed differences of up to 65.0% and 33.8%, respectively, compared to safety management report. The shielding evaluation conducted in each treatment room showed that the transmitted dose at every location was below 1% of the dose limit. The results of program and measurements showed a maximum difference of 0.003 mSv/week in transmitted dose. The ORSE program allows for the shielding evaluation results to the clinical environment of each institution based on patient data.


Asunto(s)
Aceleradores de Partículas , Protección Radiológica , Aceleradores de Partículas/instrumentación , Protección Radiológica/instrumentación , Protección Radiológica/métodos , Humanos , Radioterapia de Intensidad Modulada/métodos , Dosis de Radiación
3.
PLoS One ; 19(4): e0301435, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38635642

RESUMEN

In radiotherapy, when photon energy exceeding 8 MV is utilized, photoneutrons can activate the components within the gantry of the linear accelerator (linac). At the end of the linac's lifecycle, radiation workers are tasked with its dismantling and disposal, potentially exposing them to unintentional radiation. This study aims to identify and measure the radioisotopes generated by this activation through spectroscopy, and to evaluate the effective dose rate. We selected nine medical linacs, considering various factors such as manufacturer (Siemens, Varian, and Elekta), model, energy, period of operation, and workload. We identified the radionuclides in the linac head by employing an in situ high-purity germanium (HPGe) detector. Spectroscopy and dose-rate measurements were conducted post-shutdown. We also measured the dose rates at the beam-exit window following irradiation with 10 MV and 15 MV photon beams. As a result of the spectroscopy, we identified approximately 20 nuclides including those with half-lives of 100 days or longer, such as 54Mn, 60Co, 65Zn, 122Sb, and 198Au. The dose rate measurements after 10 MV irradiation decreased to the background level in 10 min. By contrast, on 15 MV irradiation, the dose rate was 628 nSv/h after 10 min and decreased to 268 nSv/h after 1.5 hours. It was confirmed that the difference in the level of radiation and the type of nuclide depends on the period of use, energy, and workload. However, the type of nuclide does not differ significantly between the linacs. It is necessary to propose appropriate guidelines for the safety of workers, and disposal/move-install should be planned while taking into consideration the equipment's energy usage rate.


Asunto(s)
Manganeso , Radioisótopos , Humanos , Dosificación Radioterapéutica , Aceleradores de Partículas , Fotones , Análisis Espectral
4.
Yonsei Med J ; 65(4): 217-226, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38515359

RESUMEN

PURPOSE: Research on the relationship between diet and dementia among Koreans are lacking. This study investigated the association between dietary habits and dementia progression over 3 years in patients with Alzheimer's disease dementia (ADD). MATERIALS AND METHODS: This study included 705 patients with mild-to-moderate ADD. Dietary habits were assessed using the Mini Dietary Assessment Index, comprising 10 questions. Outcome measures included the Clinical Dementia Rating scale-Sum of Boxes (CDR-SB), Seoul-Instrumental Activities of Daily Living, Caregiver-Administered Neuropsychiatric Inventory (CGA-NPI), and neuropsychological test battery (NTB) z-scores, which were evaluated annually over 3 years. RESULTS: In Q10 (eat all food evenly without being picky), the 3-year mean differences in CDR-SB (increases in scores represent worsening) compared to the "rarely" group were -1.86 [95% confidence interval (CI)=-3.64 - -0.09, p=0.039] for the "usually" group and -2.23 (95% CI=-4.40 - -0.06, p=0.044) for the "always" group. In Q7 (add salt or soy sauce to food when eating), the 3-year mean differences in CDR-SB compared to the "always" group were -2.47 (95% CI=-4.70 - -0.24, p=0.030) for the "usually" group and -3.16 (95% CI=-5.36 - -0.96, p=0.005) for the "rarely" group. The "rarely" and "usually" groups in Q7 showed significantly less decline in NTB z-score and CGA-NPI compared to the "always" group. CONCLUSION: Eating a balanced diet and reducing salt intake were associated with a slower decline in dementia severity, cognition, and behavioral alterations in patients with ADD.


Asunto(s)
Enfermedad de Alzheimer , Humanos , Actividades Cotidianas , Pruebas Neuropsicológicas , Cognición , Conducta Alimentaria , Progresión de la Enfermedad
6.
Phys Eng Sci Med ; 47(2): 443-451, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38224383

RESUMEN

With the increasing use of flattening filter free (FFF) beams, it is important to evaluate the impact on the skin dose and target coverage of breast cancer treatments. This study aimed to compare skin doses of treatments using FFF and flattening filter (FF) beams for breast cancer. The study established treatment plans for left breast of an anthropomorphic phantom using Halcyon's 6-MV FFF beam and TrueBeam's 6-MV FF beam. Volumetric modulated arc therapy (VMAT) with varying numbers of arcs and intensity modulated radiation therapy (IMRT) were employed, and skin doses were measured at five points using Gafchromic EBT3 film. Each measurement was repeated three times, and averaged to reduce uncertainty. All plans were compared in terms of plan quality to ensure homogeneous target coverage. The study found that when using VMAT with two, four, and six arcs, in-field doses were 19%, 15%, and 6% higher, respectively, when using Halcyon compared to TrueBeam. Additionally, when using two arcs for VMAT, in-field doses were 10% and 15% higher compared to four and six arcs when using Halcyon. Finally, in-field dose from Halcyon using IMRT was about 1% higher than when using TrueBeam. Our research confirmed that when treating breast cancer with FFF beams, skin dose is higher than with traditional FF beams. Moreover, number of arcs used in VMAT treatment with FFF beams affects skin dose to the patient. To maintain a skin dose similar to that of FF beams when using Halcyon, it may be worth considering increasing the number of arcs.


Asunto(s)
Neoplasias de la Mama , Aceleradores de Partículas , Fantasmas de Imagen , Dosificación Radioterapéutica , Radioterapia de Intensidad Modulada , Piel , Humanos , Piel/efectos de la radiación , Femenino , Neoplasias de la Mama/radioterapia , Mama/efectos de la radiación , Mama/diagnóstico por imagen , Planificación de la Radioterapia Asistida por Computador , Relación Dosis-Respuesta en la Radiación , Dosis de Radiación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...