Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 54
Filtrar
1.
J Med Ultrasound ; 31(2): 147-149, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37576414

RESUMEN

Core needle biopsy of breast masses is a common procedure for tissue diagnosis of breast lesions. The incidence of complications is low, with pseudoaneurysm (PA) after core biopsy has been described in the literature, and the subsequent need for surgical management. Ultrasonography is the most common modality used for not only diagnosis but also treatment of a PA. Color Doppler images show a heterogeneous echoic lesion with whirling flow inside of the lesion. We describe a patient whose breast PA that developed after core needle biopsy was successfully treated with sonographically-guided intravascular glue embolization.

2.
Taehan Yongsang Uihakhoe Chi ; 83(3): 608-619, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-36238503

RESUMEN

Purpose: This study aimed to evaluate the natural growth of subepithelial tumors of the small bowel detected on CT. Materials and Methods: Consecutive patients who were suspected of having subepithelial tumors of the small bowel between January 2005 and December 2020 were reviewed. Eligible patients with suspected small (< 30 mm) subepithelial tumors on at least two CT evaluations were included in the analysis. The patients' data on demographic characteristics, tumoral characteristics, and tumoral size changes during the follow-up were collected. Results: This study included 64 patients with suspected small subepithelial tumors (n = 64) of the small bowel. After a median follow-up of 15.8 months, the diameter and volume growth rates were 0.02 mm/month and 1.5 mm3/month, respectively. A significant correlation was observed between the initial size and the growth rate of the small bowel subepithelial tumors. The group of large-sized tumors (initial diameter ≥ 10 mm) tended to show lobulated contours, heterogeneous enhancement, and necrotic changes more frequently than the group of small-sized tumors (initial diameter < 10 mm). Conclusion: Small bowel subepithelial tumors measuring less than 10 mm grew more slowly than those measuring 10-30 mm.

3.
J Korean Soc Radiol ; 83(4): 808-829, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36238905

RESUMEN

Hepatocellular carcinoma (HCC) can be diagnosed noninvasively on multiphasic CT and MRI based on its distinctive imaging findings. These features include arterial phase hyperenhancement and washout on portal or delayed phase images. However, radiologists face significant diagnostic challenges because some HCCs exhibit atypical imaging characteristics. In addition to many HCC-mimicking lesions, such as arterioportal shunts, combined HCC-cholangiocarcinoma, intrahepatic cholangiocarcinoma, and hemangioma present a challenge for radiologists in actual clinical practice. The ability to distinguish HCCs from mimickers on initial imaging examinations is crucial for appropriate management and treatment decisions. Therefore, this pictorial review presents the imaging findings of atypical HCCs and HCCs mimicking malignant and benign lesions and discusses important clues that may help narrow down the differential diagnosis.

4.
Medicine (Baltimore) ; 101(34): e30376, 2022 Aug 26.
Artículo en Inglés | MEDLINE | ID: mdl-36042611

RESUMEN

This study aimed to investigate the clinical outcomes of causative microorganisms in obstructive pyelonephritis associated with ureteral stones (OPU) and their antibiotic susceptibilities. This retrospective cohort study included female patients diagnosed with community-acquired acute pyelonephritis (APN) at a tertiary-care hospital between 2008 and 2017. A comparison of APN cases associated with the obstruction of the upper urinary tract by ureteral stones and APN cases without complications was performed. Propensity score (PS) matching was used to adjust the heterogeneity within each group. Of the 588 female patients with community-acquired APN, 107 were diagnosed with OPU and 481 with uncomplicated APN. After PS matching, Enterobacteriaceae strains isolated from OPU cases were more resistant to fluoroquinolones (51.9% vs 16.0%, P < .001). Extended-spectrum ß-lactamase was detected in 22.2% and 21.0% of the Enterobacteriaceae strains isolated from OPU and uncomplicated APN cases, respectively (P = 1.000). The treatment failure rate was similar in OPU and uncomplicated APN groups (16.0% vs 21.0%, P = .545). Patients with OPU may be empirically treated with antibiotics in accordance with the treatment protocol for general pyelonephritis. Clinicians should exercise caution in prescribing fluoroquinolones for treating OPU.


Asunto(s)
Infecciones Comunitarias Adquiridas , Pielonefritis , Enfermedad Aguda , Antibacterianos/farmacología , Antibacterianos/uso terapéutico , Infecciones Comunitarias Adquiridas/tratamiento farmacológico , Farmacorresistencia Bacteriana , Enterobacteriaceae , Femenino , Fluoroquinolonas/farmacología , Fluoroquinolonas/uso terapéutico , Humanos , Pielonefritis/complicaciones , Pielonefritis/tratamiento farmacológico , Estudios Retrospectivos
5.
J Med Ultrasound ; 30(2): 116-124, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35832367

RESUMEN

Background: The purpose of this study was to compare the performance between noncontrast-enhanced computed tomography (NECT) plus abdominal ultrasound (US) (NECT + US) with contrast-enhanced computed tomography (CECT) for the detection of hepatic metastasis in breast cancer patient with postsurgical follow-up. Methods: A total of 1470 patients without already diagnosed hepatic metastasis were included. All patients underwent US and multiphase CECT including the NECT. Independent reviewers analyzed images obtained in four settings, namely, abdominal US, NECT, NECT + US, and CECT and recorded liver metastases using a 5-grade scale of diagnostic confidence. Sensitivity, specificity (diagnostic performance), and area under the receiver operating characteristic curve (AUC, diagnostic confidence) were calculated. Interoperator agreement was calculated using the kappa test. Results: Reference standards revealed no metastases in 1108/1470 patients, and metastasis was detected in 362/1470 patients. Abdominal US (P < 0.01) and NECT (P = 0.01) significantly differed from CECT, but NECT + US did not significantly differ from CECT in terms of sensitivity (P = 0.09), specificity (P = 0.5), and AUC (P = 0.43). After an additional review of abdominal US, readers changed the diagnostic confidence scores of 106 metastatic lesions diagnosed using NECT. Interobserver agreements were good or very good in all four settings. Additional review of abdominal US with NECT allowed a change in the therapeutic plan of 108 patients. Conclusion: Abdominal US + NECT showed better diagnostic performance for the detection of hepatic metastases than did NECT alone; its diagnostic performance and confidence were similar to those of CECT.

6.
Asia Pac J Clin Oncol ; 18(4): 363-370, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34219355

RESUMEN

AIM: Abdominopelvic computed tomography (APCT) is a commonly used staging investigation to detect asymptomatic metastasis in breast cancer including early breast cancer (EBC). This study aimed to assess the usefulness of APCT in breast cancers at each clinical stage. METHODS: Patients with new or recurrent invasive breast cancer between January 2009 and December 2014 were included in the study. All staging APCT results were reviewed to evaluate its yield and false positive rate (FPR) and how many investigations are needed to confirm indeterminate results. Odds ratios (ORs) for positive APCT results were calculated for possible risk factors for asymptomatic metastasis. RESULTS: Sixty-five asymptomatic metastases were detected from 1002 APCTs, giving an overall yield of 6.5%. The overall false-positive rate was 14.9 % due to 149 indeterminate findings that were found not to be metastases after further investigations or observation. Whereas the APCTs have a low yield of 3.1% in EBC, but advanced breast cancer and recurrent breast cancer have a high incidence of asymptomatic metastases (13.8% and 16.3%, respectively). The most common cause of indeterminate findings was small liver nodules, including liver cysts and liver hemangiomas. Human epidermal growth factor receptor2 (HER2) status and tumor stage are most significant predictors for positive results of staging APCT scans with high ORs (3.9 and 3.7, respectively). CONCLUSION: Staging APCT is associated with a high incidence of FPRs and low yield, especially among EBCs. It is desirable to choose this investigation more selectively according to HER2 status and tumor stage.


Asunto(s)
Neoplasias de la Mama , Neoplasias Hepáticas , Neoplasias de la Mama/patología , Femenino , Humanos , Neoplasias Hepáticas/patología , Recurrencia Local de Neoplasia/diagnóstico por imagen , Recurrencia Local de Neoplasia/patología , Estadificación de Neoplasias , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos
7.
Korean J Radiol ; 22(7): 1066-1076, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33739633

RESUMEN

OBJECTIVE: To evaluate the performance of the 2018 Korean Liver Cancer Association-National Cancer Center (KLCA-NCC) Practice Guidelines (hereafter, PG) for the diagnosis of hepatocellular carcinoma (HCC) using gadoxetic acid-enhanced MRI, compared to the Liver Imaging-Reporting and Data System (LI-RADS) version 2018 (hereafter, v2018). MATERIALS AND METHODS: From January 2013 to October 2015, treatment-naïve hepatic lesions (≥ 1 cm) on gadoxetic acid-enhanced MRI in consecutive patients with chronic hepatitis B or cirrhosis were retrospectively evaluated. For each lesion, three radiologists independently analyzed the imaging features and classified the lesions into categories according to the 2018 KLCA-NCC PG and LI-RADS v2018. The imaging features and categories were determined by consensus. Generalized estimating equation (GEE) models were used to compare the per-lesion diagnostic performance of the 2018 KLCA-NCC PG and LI-RADS v2018 using the consensus data. RESULTS: In total, 422 lesions (234 HCCs, 45 non-HCC malignancies, and 143 benign lesions) from 387 patients (79% male; mean age, 59 years) were included. In all lesions, the definite HCC (2018 KLCA-NCC PG) had a higher sensitivity and lower specificity than LR-5 (LI-RADS v2018) (87.2% [204/234] vs. 80.8% [189/234], p < 0.001; 86.2% [162/188] vs. 91.0% [171/188], p = 0.002). However, in lesions of size ≥ 2 cm, the definite HCC had a higher sensitivity than the LR-5 (86.8% [164/189] vs. 82.0 (155/189), p = 0.002) without a reduction in the specificity (80.0% [48/60] vs. 83.3% [50/60], p = 0.15). In all lesions, the sensitivity and specificity of the definite/probable HCC (2018 KLCA-NCC PG) and LR-5/4 did not differ significantly (89.7% [210/234] vs. 91.5% [214/234], p = 0.204; 83.5% [157/188] vs. 79.3% [149/188], p = 0.071). CONCLUSION: For the diagnosis of HCC of size ≥ 2 cm, the definite HCC (2018 KLCA-NCC PG) had a higher sensitivity than LR-5, without a reduction in specificity. The definite/probable HCC (2018 KLCA-NCC PG) had a similar sensitivity and specificity to that those of the LR-5/4.


Asunto(s)
Carcinoma Hepatocelular , Hepatitis B Crónica , Neoplasias Hepáticas , Carcinoma Hepatocelular/diagnóstico por imagen , Medios de Contraste , Femenino , Gadolinio DTPA , Humanos , Cirrosis Hepática/diagnóstico por imagen , Neoplasias Hepáticas/diagnóstico por imagen , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Sensibilidad y Especificidad
8.
Br J Radiol ; 94(1118): 20201087, 2021 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-33306919

RESUMEN

OBJECTIVES: To evaluate the effectiveness of follow-up with non-enhanced CT (NECT) in patients with breast cancer. METHODS: The present retrospective study included 1396 patients with breast cancer. Group A included patients with no metastasis to evaluate the diagnostic performance of NECT in detecting newly developed metastasis. Group B included patients with known hepatic metastasis to evaluate the accuracy of NECT for the assessment of hepatic metastasis. RESULTS: Group A included 895 patients (mean age 52.8 years). Among them, 145 patients had 160 metastases. The per-patient sensitivities for diagnosing newly developed metastasis were 68.3 and 53.8% according to the two reviewers, while the per-lesion sensitivities were 89.4 and 85.0%. Sensitivities for bone metastasis were 98.9 and 95.9%, while sensitivities for hepatic metastasis were 73.7 and 68.4%. In group B, the accuracy of hepatic metastasis response evaluation according to the RECIST criteria was 70.8% for reviewer 1 and 63.8% for reviewer 2. CONCLUSIONS: NECT showed inadequate diagnostic performance in detecting newly developed metastasis and in evaluating the response of hepatic metastasis. However, NECT can be utilized as a follow-up modality in patients with decreased renal function or hypersensitivity to iodinated contrast media. ADVANCES IN KNOWLEDGE: The risk of side effects of contrast media should be considered as important when NECT can be utilized as a follow-up modality in decreased renal function patients.


Asunto(s)
Neoplasias Abdominales/diagnóstico por imagen , Neoplasias Óseas/diagnóstico por imagen , Neoplasias de la Mama/patología , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Pélvicas/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Neoplasias Abdominales/secundario , Adulto , Anciano , Anciano de 80 o más Años , Neoplasias Óseas/secundario , Femenino , Estudios de Seguimiento , Humanos , Neoplasias Hepáticas/secundario , Persona de Mediana Edad , Neoplasias Pélvicas/secundario , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad , Adulto Joven
9.
Abdom Radiol (NY) ; 46(2): 723-731, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-32857260

RESUMEN

OBJECTIVE: Sepsis is major determinants of prognosis in acute pyelonephritis (APN). This study aimed to assess factors associated with the development of sepsis among patients with clinically uncomplicated APN. SUBJECTS AND METHODS: We examined 463 patients presenting to our hospital without complications. We assessed clinical factors including demographic and laboratory features. Renal and extrarenal features on computed tomography (CT) were also analyzed. Risk factors of sepsis are assessed. RESULTS: The study included 361 patients without (78.0%) and 102 patients with sepsis (22.0%). Crude and attributable mortality rates were 3.9% and 2.0% versus 1.4% and 0.6%, respectively, among patients with and without sepsis. Clinical risk factors for sepsis were age >65 years (odds ratio [OR] 1.79, P = 0.02), absence of flank pain (OR 1.59, P = 0.04), absence of costovertebral tenderness (OR 1.89, P = 0.03), diabetes mellitus (OR 2.25, P = 0.02), bacteremia (OR 2.8, P = 0.01), C-reactive protein level >100 mg/L (OR 1.42, P = 0.02), and lack of previous APN history (OR 1.76, P = 0.04). APN grade IV (OR 3.16, P = 0.01), high grade hydronephrosis (OR 1.50, P = 0.03), diffuse peritoneal thickening (OR 4.12, P = 0.01), and acute interstitial pulmonary edema (OR 3.73, P = 0.01) were the CT features predictive of septic shock. CONCLUSIONS: Although uncomplicated APN was largely non-fatal, several clinical and CT features could lead to sepsis. Our findings may be useful for predicting sepsis risk and deciding whether intravenous antibiotic treatment and intensive management should be initiated for uncomplicated APN.


Asunto(s)
Pielonefritis , Sepsis , Enfermedad Aguda , Anciano , Femenino , Humanos , Pielonefritis/diagnóstico por imagen , Estudios Retrospectivos , Sepsis/diagnóstico por imagen , Tomografía Computarizada por Rayos X
10.
Eur Radiol ; 31(4): 2433-2443, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33000305

RESUMEN

OBJECTIVES: To predict poor survival and tumor recurrence in patients with ampullary adenocarcinoma using preoperative clinical and CT findings. MATERIALS AND METHODS: A total of 216 patients with ampullary adenocarcinoma who underwent preoperative CT and surgery were retrospectively included. CT was assessed by two radiologists. Clinical and histopathological characteristics including histologic subtypes were investigated. A Cox proportional hazard model and the Kaplan-Meier method were used to identify disease-free survival (DFS) and overall survival (OS). A nomogram was created based on the multivariate analysis. The optimal cutoff size of the tumor was evaluated and validated by internal cross validation. RESULTS: The median OS was 62.8 ± 37.9, and the median DFS was 54.3 ± 41.2 months. For OS, tumor size (hazard ratio [HR] 2.79, p < 0.001), papillary bulging (HR 0.63, p = 0.049), organ invasion on CT (HR 1.92, p = 0.04), male sex (HR 1.59, p = 0.046), elevated CA 19-9 (HR 1.92, p = 0.01), pT stage (HR 2.45, p = 0.001), and pN stage (HR 3.04, p < 0.001) were important predictors of survival. In terms of recurrence, tumor size (HR 2.37, p = 0.04), pT stage (HR 1.76, p = 0.03), pN stage (HR 2.23, p = 0.001), and histologic differentiation (HR 4.31, p = 0.008) were important predictors of recurrence. In terms of tumor size on CT, 2.65 cm and 3.15 cm were significant cutoff values for poor OS and RFS (p < 0.001). CONCLUSION: Preoperative clinical and CT findings were useful to predict the outcomes of ampullary adenocarcinoma. In particular, tumor size, papillary bulging, organ invasion on CT, male sex, and elevated CA 19-9 were important predictors of poor survival after surgery. KEY POINTS: • Clinical staging based on preoperative clinical information and CT findings can be useful to predict the prognosis of ampullary adenocarcinoma patients. • In terms of survival, tumor size (HR 2.79), papillary bulging (HR 0.63), organ invasion on CT (HR 1.92), male sex (HR 1.59), and elevated CA 19-9 (HR 1.92) were important clinical predictors of poor survival. • Tumor size on CT was of special importance for both poor overall survival and disease-free survival, with optimal cutoff values of 2.65 cm and 3.15 cm, respectively (p < 0.001).


Asunto(s)
Adenocarcinoma , Recurrencia Local de Neoplasia , Adenocarcinoma/diagnóstico por imagen , Adenocarcinoma/patología , Adenocarcinoma/cirugía , Supervivencia sin Enfermedad , Humanos , Masculino , Recurrencia Local de Neoplasia/diagnóstico por imagen , Estadificación de Neoplasias , Pronóstico , Estudios Retrospectivos , Tomografía Computarizada por Rayos X
11.
Liver Cancer ; 9(5): 503-517, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-33083277

RESUMEN

BACKGROUND AND AIMS: Biannual ultrasonography (US) is a current recommendation for hepatocellular carcinoma (HCC) surveillance in a high-risk group. The sensitivity of US, however, has been low in patients with a high risk of developing HCC. We aimed to compare sensitivity for HCC of biannual US and two-phase low-dose computed tomography (LDCT) in patients with a high risk of HCC. METHODS: In this prospective single-arm study, participants with an annual risk of HCC greater than 5% (based on a risk index of ≥2.33) and who did not have a history of HCC were enrolled from November 2014 to July 2016. Participants underwent paired biannual US and two-phase LDCT 1-3 times. Two-phase LDCT included arterial and 3-min delayed phases. The sensitivity, specificity, and positive predictive value of HCC detection using US and two-phase LDCT were compared using a composite algorithm as a standard of reference. RESULTS: Of the 139 enrolled participants, 137 underwent both the biannual US and two-phase LDCT at least once and had follow-up images. Among them, 27 cases of HCC (mean size: 14 ± 4 mm) developed in 24 participants over 1.5 years. Two-phase LDCT showed a significantly higher sensitivity (83.3% [20/24] vs. 29.2% [7/24], p < 0.001) and specificity (95.6% [108/113] vs. 87.7% [99/113], p =0.03) than US. A false-positive result was reported in 14 participants at US and 5 participants at two-phase LDCT, resulting in a significantly higher positive predictive value of two-phase LDCT (33.3% [7/21] vs. 80% [20/25], p < 0.001). CONCLUSIONS: Patients with a risk index ≥2.33 showed a high annual incidence of HCC development in our study, and two-phase LDCT showed significantly higher sensitivity and specificity for HCC detection than US.

12.
PLoS One ; 15(9): e0231431, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32881876

RESUMEN

OBJECTIVE: To compare the radiation dose and the objective and subjective image quality of 80 kVp and 80/150 kVp with tin filter (80/Sn150 kVp) computed tomography (CT) in oncology patients. METHODS: One-hundred-and-forty-five consecutive oncology patients who underwent third-generation dual-source dual-energy CT of the abdomen for evaluation of malignant visceral, peritoneal, extraperitoneal, and bone tumor were retrospectively recruited. Two radiologists independently reviewed each observation in 80 kVp CT and 80/Sn150 kVp CT. Modified line-density profile of the tumor and contrast-to-noise ratio (CNR) were measured. Diagnostic confidence, lesion conspicuity, and subjective image quality were calculated and compared between image sets. The effective dose and size-specific dose estimate (SSDE) were calculated in the image sets. RESULTS: Modified line-density profile analysis revealed higher attenuation differences between the tumor and normal tissue in 80 kVp CT than in 80/Sn150 kVp CT (127 vs. 107, P = 0.05). The 80 kVp CT showed increased CNR in the liver (8.0 vs. 7.6) and the aorta (18.9 vs. 16.3) than the 80/Sn150 kVp CT. The 80 kVp CT yielded higher enhancement of organs (4.9 ± 0.2 vs. 4.7 ± 0.4, P<0.001) and lesion conspicuity (4.9 ± 0.3 vs. 4.8 ± 0.5, P = 0.035) than the 80/Sn150 kVp CT; overall image quality and confidence index were comparable. The effective dose was reduced by 45.2% with 80 kVp CT (2.3 mSv ± 0.9) compared to 80/Sn150 kVp CT (4.1 mSv ± 1.5). The SSDE was 7.4 ± 3.8 mGy on 80/Sn150 kVp CT and 4.1 ± 2.2 mGy on 80 kVp CT. CONCLUSIONS: The 80 kVp CT reduced the radiation dose by 45.2% in oncology patients while showing comparable or superior image quality to that of 80/Sn150 kVp CT for abdominal tumor evaluation.


Asunto(s)
Neoplasias/diagnóstico por imagen , Dosis de Radiación , Intensificación de Imagen Radiográfica/instrumentación , Estaño , Tomografía Computarizada por Rayos X/instrumentación , Abdomen/diagnóstico por imagen , Anciano , Algoritmos , Medios de Contraste/administración & dosificación , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pelvis/diagnóstico por imagen , Intensificación de Imagen Radiográfica/métodos , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos
13.
Acta Radiol ; 61(11): 1452-1462, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32228032

RESUMEN

BACKGROUND: Previous studies evaluating predictive factors for the conversion from laparoscopic to open cholecystectomy have reported conflicting conclusions. PURPOSE: To create a risk assessment model to predict the conversion from laparoscopic to open cholecystectomy in patients with acute calculous cholecystitis. MATERIAL AND METHODS: A retrospective review of patients with acute calculous cholecystitis with available preoperative contrast-enhanced computed tomography (CT) findings who underwent laparoscopic cholecystectomy was performed. Forty-four parameters-including demographics, clinical history, laboratory data, and CT findings-were analyzed. RESULTS: Among the included 581 patients, conversion occurred in 113 (19%) cases. Multivariate analysis identified obesity (odd ratio [OR] 2.58, P = 0.04), history of abdominal surgery (OR 1.78, P = 0.03), and prolonged prothrombin time (OR 1.98, P = 0.03) as predictors of conversion. In preoperative CT findings, the absence of gallbladder wall enhancement (OR 3.15, P = 0.03), presence of a gallstone in the gallbladder infundibulum (OR 2.11, P = 0.04), and inflammation of the hepatic pedicle (OR 1.71, P = 0.04) were associated with conversion. Inter-observer agreement for CT study interpretation was very good (range 0.81-1.00). A model was created to calculate the risk for conversion, with an area under the receiver operating characteristic curve of 0.87. The risk for conversion, estimated based on the number of factors identified, was in the range of 5.3% (with one factor) to 86.4% (with six factors). CONCLUSION: Obesity, history of abdominal surgery, prolonged prothrombin time, absence of gallbladder wall enhancement, presence of a gallstone in the gallbladder infundibulum, and inflammation of the hepatic pedicle are associated with conversion of laparoscopic to open cholecystectomy.


Asunto(s)
Colecistectomía Laparoscópica/métodos , Colecistitis Aguda/diagnóstico por imagen , Colecistitis Aguda/cirugía , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Vesícula Biliar/diagnóstico por imagen , Vesícula Biliar/cirugía , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Medición de Riesgo , Adulto Joven
14.
Eur Radiol ; 30(5): 2861-2870, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-32006170

RESUMEN

OBJECTIVES: This study was conducted in order to assess the performance of the Liver Imaging Reporting and Data System (LI-RADS) treatment response (TR) (LR-TR) categorization on gadoxetic acid-enhanced MRI (Gd-EOB-MRI) for detecting viable tumors in hepatocellular carcinoma (HCC) treated with locoregional treatment (LRT) and to investigate the added value of ancillary features (AFs) to conventional enhancement-based criteria. METHODS: This retrospective study included 183 patients with Gd-EOB-MRI after LRT for HCC and appropriate reference standards for tumor viability (84 viable and 99 nonviable). Two independent radiologists assigned per-lesion mRECIST and TR categories (TR-nonviable, TR-equivocal, or TR-viable) according to the LR-TR algorithm and modified LR-TR algorithms including mLR-TR(TP) allowing transitional phase (TP) washout and mLR-TR(AF) allowing category adjustment by applying AFs. Diagnostic performances of imaging criteria were compared using the Cochran's Q test with post hoc analysis. RESULTS: For detecting viable tumors, LR-TR-viable resulted in sensitivities of 64.5%/39.3% and specificities of 98.0%/98.0% in reviewers 1/2. In comparison to LR-TR-viable, mRECIST-viable, mLR-TR(TP)-viable, and mLR-TR(AF)-viable showed significantly higher sensitivities (92.9%/94.0%, 77.4%/56.6%, and 86.9%/83.3% in reviewers 1/2) (ps < 0.001). The specificity of mRECIST-viable (73.7%/62.6%) was significantly lower than that of LR-TR-viable (ps < 0.001), while those of mLR-TR(TP)-viable and mLR-TR(AF)-viable were greater than 95% (98.0%/96.0% and 97.0%/96.0%), statistically equivalent to LR-TR-viable (ps > 0.05). TR-equivocal was least assigned on mLR-TR(AF) (1.1%/7.7%) than LR-TR (15.8%/32.2%) or mLR-TR(TP) (6.6%/23.5%) in both reviewers. CONCLUSION: The LR-TR algorithm on Gd-EOB-MRI provides a specific diagnosis of viable tumor but with limited sensitivity. By applying AFs in the category adjustment, more sensitive and confident diagnosis can be achieved without significant loss of specificity. KEY POINTS: • The LI-RADS treatment response (LR-TR) algorithm on Gd-EOB-MRI provides a highly specific diagnosis of viable HCC but with limited sensitivity. • The inferior sensitivity of LR-TR-viable category to that of mRECIST can be improved by applying ancillary features in the category adjustment.


Asunto(s)
Carcinoma Hepatocelular/diagnóstico por imagen , Gadolinio DTPA , Aumento de la Imagen/métodos , Neoplasias Hepáticas/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Sistemas de Información Radiológica/estadística & datos numéricos , Algoritmos , Carcinoma Hepatocelular/terapia , Medios de Contraste , Femenino , Humanos , Hígado/diagnóstico por imagen , Neoplasias Hepáticas/terapia , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad , Resultado del Tratamiento
15.
Abdom Radiol (NY) ; 45(9): 2669-2679, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-31894381

RESUMEN

PURPOSE: The incidence of Klebsiella pneumoniae pyogenic liver abscesses (KP-PLA) is increasing. However, its diagnosis and treatment are often delayed, leading to complications. In this study, we aimed to retrospectively compare computed tomographic (CT) features of KP-PLAs with those of abscesses caused by other bacterial pathogens (non-KP-PLAS) and to further identify prognostic factors for PLA. METHODS: Data of 219 study patients including clinical presentation, comorbid conditions, metastatic infection, treatment duration, and mortality were retrospectively collated. CT characteristics of abscesses were recorded. Etiology was established by pus and/or blood culture. The differentiating CT features and clinical findings were compared between the monomicrobial KP-PLA and non-KP-PLA groups. Furthermore, factors related to in-hospital case fatality were analyzed. RESULTS: Multivariate analysis identified thin-walled abscesses, absent rim enhancement, metastatic infection, and absence of underlying biliary tract disease as significant predictors of KP-PLA. With 3/4 criteria applied in combination, a specificity of 96.5% was achieved for KP-PLA diagnosis. The in-hospital mortality rate was 3.7%. Multivariate analysis revealed that diabetes mellitus (P = 0.031), multiple abscesses (P = 0.026), internal gas bubble (P = 0.041), metastatic infection (P = 0.004), and septic shock (P = 0.002) were significantly associated with mortality. CONCLUSION: Thin-walled abscess, metastatic infection, absence of rim enhancement, and absence of underlying biliary tract disease are potentially useful CT findings for early KP-PLA diagnosis.


Asunto(s)
Infecciones por Klebsiella , Absceso Piógeno Hepático , Humanos , Infecciones por Klebsiella/diagnóstico por imagen , Klebsiella pneumoniae , Absceso Piógeno Hepático/diagnóstico por imagen , Estudios Retrospectivos , Tomografía Computarizada por Rayos X
16.
Acta Radiol ; 61(8): 1105-1115, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-31795730

RESUMEN

BACKGROUND: Patients with renal stones receive multiple computed tomography (CT) examinations. We investigated whether submillisievert (sub-mSv) CT for stone detection could reduce radiation dose at exposure levels comparable to kidney, ureter, and bladder (KUB) radiography. PURPOSE: To evaluate the radiation dose exposure, diagnostic performance, and image quality of sub-mSv non-contrast CT using advanced modelled iterative reconstruction algorithm with spectral filtration for the detection of urolithiasis. MATERIAL AND METHODS: A total of 145 consecutive patients underwent non-contrast CT using a third-generation dual-source scanner to obtain two datasets, i.e. 16.7% (sub-mSv CT, tube detector A) and 100% (standard-dose CT, combination of tube detector A and B) tube loads with spectral filtration. The performance of sub-mSv CT for the detection of stones was analyzed by two readers and compared with that of standard-dose CT. Image quality was measured subjectively and objectively. RESULTS: In total, 171 stones were detected in 79 patients. The mean effective radiation doses of sub-mSv CT was 0.3 mSv. The sensitivity and specificity values for diagnosis of stones measuring ≥3 mm was 95.1% and 100% for sub-mSv CT. The sensitivity and specificity for all stone detection was 74.9% and 97.8%, respectivey, for sub-mSv CT. The image quality was lower for sub-mSv CT than for standard-dose CT (P < 0.01). CONCLUSION: Sub-mSv CT can be achieved with radiation doses close to KUB radiography. Sub-mSv CT with spectral filtration can be used to detect stones measuring ≥3 mm and be used as a follow-up imaging modality as an alternative to KUB radiography.


Asunto(s)
Tomografía Computarizada por Rayos X/métodos , Urolitiasis/diagnóstico por imagen , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Dosis de Radiación , Exposición a la Radiación , Sensibilidad y Especificidad
17.
Ultrasonography ; 39(2): 121-129, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31693842

RESUMEN

PURPOSE: The purpose of this study was to evaluate the intra-observer reproducibility of ultrasound attenuation imaging (ATI) for the noninvasive assessment of hepatic steatosis in patients with suspected hepatic steatosis and the inter-observer reproducibility in asymptomatic volunteers. METHODS: This prospective study was approved by our institutional review board and informed consent was obtained from all patients. In group 1, composed of patients with suspected hepatic steatosis (n=143), one abdominal radiologist performed gray-scale ultrasonography and two sessions of ATI. In group 2, composed of healthy volunteers (n=18), three independent sessions of ATI were performed by three abdominal radiologists. The visual degree of hepatic steatosis in all study subjects was graded on a 4-point scale by two independent reviewers using gray-scale ultrasonography. Thereafter, the attenuation coefficient (AC) was correlated with the degree of hepatic steatosis using Spearman rank correlation analysis. Intra-class correlation coefficients (ICCs) were used to assess the intra-observer (group 1) and inter-observer reproducibility (group 2) of ATI measurements. RESULTS: For the intra-observer reproducibility of ATI, the ICC was 0.929 (95% confidence interval [CI], 0.901 to 0.949), and the coefficient of variation was 7.1%. Inter-observer reproducibility of ATI measurements showed an ICC of 0.792 (95% CI, 0.549 to 0.916). The AC showed a significant correlation with the visual grade of hepatic steatosis for both reviewers (rho, 0.780 and 0.695; P<0.001, respectively). CONCLUSION: ATI showed high intra- and inter-observer reproducibility in the assessment of hepatic steatosis.

18.
BJR Case Rep ; 5(3): 20190018, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31555478

RESUMEN

Extramammary Paget's disease (EMPD) is a rare cutaneous malignancy involving the scrotum and may be confused with other scrotal malignancy. We describe the sonographic findings of an extremely rare case of mass-forming EMPD of the scrotal wall. Ultrasonography, which shows mild heterogeneous hyperechoic masses with a stalk connected to the dermis, can help predict the depth of vertical invasion of the lesion. The lesion extent should be precisely evaluated because the presence of dermal invasion of EMPD is the risk factor in distant metastasis and is known to result in a worse prognosis. Ultrasonography is a primary imaging modality to evaluate the extent and vertical invasion of EMPD. Surgical local wide excision is the treatment of choice for EMPD and histopathology confirmed the diagnosis.

19.
Radiology ; 293(2): 343-349, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31502935

RESUMEN

Background Accurate assessment of local resectability of pancreatic cancer at initial workup is critical to determine the most appropriate management strategy among up-front operation, neoadjuvant treatment, or palliative treatment. Purpose To investigate the interobserver agreement of the preoperative CT classification of the local resectability of pancreatic cancer and to determine if radiologist experience level impacts evaluation, and to evaluate the reader performance in assessing resectability at CT in a subset of patients with a reference standard for local resectability. Materials and Methods This retrospective study was composed of patients with pathologic-analysis-confirmed pancreatic cancers between January 2013 and December 2014 who underwent baseline multiphasic contrast agent-enhanced CT. Eight board-certified radiologists with different levels of experience (more experienced, ≥6 years, n = 4; less experienced, 1st- or 2nd-year fellows, n = 4) reviewed the CT images and classified cancers as resectable, borderline resectable, or unresectable. Interobserver agreements were determined for all reviewers and subgroups of reviewers stratified according to experience (more vs less) by using Fleiss κ statistics. In patients with reference standards for local resectability, diagnostic performances of each reviewer were assessed by using receiver operating characteristic curve analysis. Results There were 110 patients (mean age, 61 years ± 11; 60 men) who were evaluated. Overall interobserver agreements were moderate for resectability classification (κ = 0.48; 95% confidence interval: 0.45, 0.50). Only 30.0% of patients (33 of 110) were given the same resectability classification from all reviewers. More experienced reviewers demonstrated higher agreement in category assignments than less experienced reviewers (κ = 0.55 [95% confidence interval: 0.50, 0.60] vs 0.43 [95% confidence interval: 0.38, 0.49], respectively). For prediction at CT of margin-negative (ie, R0) resections (n = 82), areas under the receiver operating characteristic curve of all reviewers were greater than 0.80 (range, 0.83-0.96). However, borderline resectable cancers showed diverse R0 rates ranging from 0% to 74% depending on the reviewers. Conclusion Considerable interobserver variability exists in the assignment at CT of the local resectability of pancreatic cancer, even among experienced radiologists. © RSNA, 2019 Online supplemental material is available for this article.


Asunto(s)
Competencia Clínica , Neoplasias Pancreáticas/diagnóstico por imagen , Neoplasias Pancreáticas/cirugía , Tomografía Computarizada por Rayos X/métodos , Anciano , Medios de Contraste , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Estudios Retrospectivos
20.
Ultrasonography ; 38(4): 345-354, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-31500403

RESUMEN

PURPOSE: The purpose of this study was to compare the technical success rate and reliability of measurements made using three shear wave elastography (SWE) techniques and to assess the inter-platform reproducibility of the resultant liver stiffness measurements. METHODS: This prospective study included 54 patients with liver disease. Liver stiffness (LS) measurements were obtained using 2-point SWE techniques (Virtual Touch Quantification and S-Shearwave) and 2-dimensional (2D) SWE, with transient elastography (TE) serving as the reference standard. The technical success rates and measurement reliability of the three techniques were compared. LS values measured using the three SWE techniques and TE were compared using Spearman correlation coefficients and 95% Bland-Altman limits of agreement. Intra-class correlation coefficients (ICC) were used to analyze the inter-platform reproducibility of LS measurements. RESULTS: The three SWE techniques and TE showed similar technical success rates (P=0.682) but demonstrated significant differences in the reliability of LS measurements (P=0.006) and mean LS measurements (P<0.001). Despite strong correlations (r=0.73-0.94) between SWE systems, various degrees of inter-platform reproducibility (ICC, 0.58-0.92) were observed for the three SWE techniques. The best agreement was observed between S-Shearwave and TE (ICC, 0.92), and the worst agreement was observed between 2D-SWE and TE (ICC, 0.58). In the BlandAltman analysis, a tendency toward lower LS values with the three SWE techniques than with TE in patients with F3 and F4 disease was observed. CONCLUSION: Significant inter-system variability was observed in LS measurements made using the three SWE techniques. Therefore, LS values measured using different SWE techniques should not be used interchangeably for longitudinal follow-up.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA