Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Curr Res Toxicol ; 4: 100100, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36619289

RESUMEN

Animal testing of cosmetic ingredients and products has been banned in the European Union since 2013. However, in Japan, the application of new quasi-drugs requires the generation of data on acute oral toxicity through animal testing. A weight of evidence approach for assessing oral toxicity was challenged. This approach used a combination of safety data, including a neutral red uptake cytotoxicity assay using BALB/c3T3 cells (3T3-NRU cytotoxicity assay), which can assess the acute oral toxicity of quasi-drugs or cosmetic ingredients. We conclude that the step-by-step approach can be used to assess test substances that cause low acute oral toxicity, such as the median lethal dose (LD 50) > 2000 mg/kg, thereby avoiding animal testing.

2.
J Appl Toxicol ; 42(6): 1029-1043, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-34927266

RESUMEN

Demands for the elimination and replacement of animal experiments for cosmetic safety assessment have increased in recent years. Evaluation of skin sensitization, however, is a critical issue in cosmetic safety assessment. The SH test is an in vitro skin sensitization test method that evaluates protein binding of chemical substances, which is an important event in skin sensitization. We previously verified the technical transferability and between-laboratory reproducibility of the SH test, a domestic test method for which no scientific research has been conducted, and improved the protocol, but also noted some unresolved issues. Therefore, in the present study, we successfully improved the operational efficiency and clarity of the final judgment of the SH test by (i) developing a new decision-making system that can make a final judgment without statistical processing, (ii) changing the statistical method, and (iii) evaluating and determining the maximum number of repetitions necessary for optimal efficiency. The improved SH test was verified by comparing it with existing test methods already adopted by the Organization for Economic Cooperation and Development. The results of this study demonstrated excellent performance of the improved SH test, with high reproducibility, reliable predictability, and good operational efficiency. The predictive performance of the improved method does not differ significantly from that of the conventional method, although it is clearer and more efficient. Therefore, the results of the present improved method are consistent with those obtained using the conventional method, with higher efficiency.


Asunto(s)
Alternativas a las Pruebas en Animales , Cosméticos , Alternativas a las Pruebas en Animales/métodos , Animales , Árboles de Decisión , Reproducibilidad de los Resultados , Piel , Pruebas Cutáneas/métodos
3.
J Toxicol Sci ; 46(5): 235-248, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33952800

RESUMEN

There has been an increased demand to eliminate animal experiments and to replace the experiments with alternative tests for assessing the safety of cosmetics. The SH test is an in vitro skin sensitization test that evaluates the protein binding abilities of a test substance. Skin sensitization must be evaluated by multiple test methods. The SH test uses the same cell line and measuring instruments as the human Cell-Line Activation Test (h-CLAT), which is one of the test methods used to evaluate different key events and is listed in the OECD test guidelines. There are cost advantages to usher the SH test into facilities that are already running the h-CLAT. The SH test is conducted only at a facility that has developed the SH test because studies on the between-facility reproducibility and validity have not been performed. Therefore, to verify the transferability of the SH test and the between-facilities reproducibility, we evaluated the reproducibility of the SH test results at three facilities, including the development facility. After an initial round of testing, the protocol was refined as follows to improve reproducibility among the three facilities: i) determine the optimum pH range, ii) change the maximum applicable concentration of water-soluble substances, and iii) define the appropriate dispersion conditions for evaluating hydrophobic substances. These refinements markedly enhanced the between-facility reproducibility (from 76.0% to 96.0%) for the 25 substances evaluated in this study. This study confirmed that the SH test is an effective skin sensitization test method with high technical transferability and between-facility reproducibility.


Asunto(s)
Dermatitis Alérgica por Contacto , Haptenos/toxicidad , Laboratorios/normas , Pruebas de Toxicidad/métodos , Pruebas de Toxicidad/normas , Alternativas a las Pruebas en Animales/métodos , Alternativas a las Pruebas en Animales/normas , Línea Celular , Humanos , Reproducibilidad de los Resultados
4.
Chemistry ; 15(36): 9191-200, 2009 Sep 14.
Artículo en Inglés | MEDLINE | ID: mdl-19650089

RESUMEN

In spite of the wide availability of various near-infrared (NIR) fluorophores as labeling reagents, there are few functional NIR fluorescent probes for which change in the absorption and/or fluorescence spectra upon specific reaction with biomolecules is seen. The widely used photoinduced electron-transfer mechanism is unsuitable for NIR fluorophores, such as tricarbocyanines, because their long excitation wavelength results in a small singlet excitation energy. We have reported the unique spectral properties of amine-substituted tricarbocyanines, which were utilized to develop two design strategies. One approach was based on control of the absorption wavelength by using the difference in electron-donating ability before and after a specific reaction with a biomolecule, and the other approach was based on control of the fluorescence intensity by modulating the Förster resonance energy-transfer efficiency through a change in the overlap integral that arises from the change in absorption under acidic conditions. These strategies were validated by obtaining tricarbocyanine-based ratiometric NIR fluorescent probes for esterase and for pH level.


Asunto(s)
Carbocianinas/química , Colorantes Fluorescentes/química , Esterasas/metabolismo , Colorantes Fluorescentes/síntesis química , Concentración de Iones de Hidrógeno , Estructura Molecular , Espectroscopía Infrarroja Corta
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...