Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 313
Filtrar
1.
ESC Heart Fail ; 2024 Sep 23.
Artículo en Inglés | MEDLINE | ID: mdl-39308333

RESUMEN

AIMS: Mitral transcatheter edge-to-edge repair (M-TEER) is a valid treatment option for severe mitral regurgitation (MR), necessitating accurate risk stratification of M-TEER candidates for effective patient selection, optimal periprocedural care and improved long-term outcomes. The body mass index (BMI) is a simple and practical prognostic index, and the obesity paradox has been widely reported. METHODS AND RESULTS: Between April 2018 and June 2021, 2149 patients undergoing M-TEER were registered in the prospective multicentre registry and classified into three groups: underweight (BMI < 18.5 kg/m2), normal weight (18.5 â‰¦ BMI < 25 kg/m2) and overweight and obese (25 kg/m2 â‰¦ BMI). The impact of underweight on the all-cause, cardiovascular and non-cardiovascular mortality following M-TEER was evaluated [follow-up duration: 436 (363-733) days]. The participants (median BMI: 21.1 kg/m2) were categorized as underweight (n = 450, 20.9%), normal weight (n = 1409, 65.6%) and overweight and obese (n = 290, 13.5%). Compared with the other two groups, the underweight group exhibited several negative prognostic factors, including older age, frailty, no dyslipidaemia, hypoalbuminaemia, residual MR and non-home discharge. Underweight patients had the highest rate of all-cause, cardiovascular and non-cardiovascular mortality, whereas those in the other two groups were similar. As per the multivariate analysis, underweight itself was associated with all-cause mortality (hazard ratio: 1.52, 95% confidence interval: 1.17-1.97, P = 0.009) and cardiovascular mortality (hazard ratio: 1.45, 95% confidence interval: 1.04-2.01, P = 0.028). CONCLUSIONS: Underweight patients had the highest mortality rate after M-TEER. Comorbidities, residual MR, discharge disposition and underweight status were correlated with postprocedural outcome.

2.
J Arrhythm ; 40(4): 1041-1044, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39139894

RESUMEN

Obstruction of a systemic venous pathway is relatively common after the Mustard operation. A helix-fixation leadless pacemaker was successfully implanted in the subpulmonic but morphologic LV in a d-TGA patient with post-Mustard baffle stenosis and failure of a previously implanted epicardial lead.

3.
J Cardiol ; 2024 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-39153660

RESUMEN

BACKGROUND: The benefit of prehospital 12­lead electrocardiogram (PH-ECG) performed by emergency medical service personnel at the site of first medical contact (FMC) in patients with ST-segment elevation myocardial infarction (STEMI) with cardiogenic shock (CS-STEMI) remains unclear. This study aimed to investigate the effect of PH-ECG on door-to-device time in patients with CS-STEMI. METHODS: This study enrolled CS-STEMI (Killip class IV) patients who were transferred directly to hospitals by ambulance (n = 517) from the Kanagawa Acute Cardiovascular Registry database. Patients were divided into PH-ECG (+) (n = 270) and PH-ECG (-) (n = 247) groups. Patients who experienced out-of-hospital cardiac arrest, who did not undergo emergent coronary intervention, or whose data were missing were excluded. Patient characteristics, FMC-to-door time, door-to-device time, and in-hospital mortality were compared between the groups. RESULTS: The patient backgrounds of the PH-ECG (+) and PH-ECG (-) groups were comparable. The peak creatinine kinase level was greater in the PH-ECG (+) group than in the PH-ECG (-) group [2756 (1292-6009) IU/ml vs. 2270 (957-5258) IU/ml, p = 0.048]. The FMC-to-door time was similar between the two groups [25 (20-33) min vs. 27 (20-35) min, p = 0.530], while the door-to-device time was significantly shorter in the PH-ECG group [74 (52-103) min vs. 83 (62-111) min, p = 0.007]. In-hospital mortality did not differ between the two groups (18 % vs. 21 %, p = 0.405). Multivariable logistic regression analyses revealed that PH-ECG (+) was independently associated with a door-to-device time < 60 min [odds ratio (95 % confidence intervals): 1.88 (1.24-2.83), p = 0.003]. CONCLUSIONS: PH-ECG was significantly associated with shorter door-to-device times in patients with CS-STEMI. Further studies with larger populations and more defined protocols are required to evaluate the utility of PH-ECG in patients with CS-STEMI.

4.
Echocardiography ; 41(8): e15892, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39023286

RESUMEN

PURPOSE: The extraaortic-valvular cardiac damage (EVCD) Stage has shown potential for risk stratification for patients with aortic stenosis (AS). This study aimed to examine the usefulness of the EVCD Stage in risk stratification of patients with moderate AS and reduced left ventricular ejection fraction (LVEF). METHODS: Clinical data from patients with moderate AS (aortic valve area, .60-.85 cm2/m2; peak aortic valve velocity, 2.0-4.0 m/s) and reduced LVEF (LVEF 20%-50%) were analyzed during 2010-2019. Patients were categorized into three groups: EVCD Stages 1 (LV damage), 2 (left atrium and/or mitral valve damage), and 3/4 (pulmonary artery vasculature and/or tricuspid valve damage or right ventricular damage). The primary endpoint included a composite of cardiac death and heart failure hospitalization, with non-cardiac death as a competing risk. RESULTS: The study included 130 patients (mean age 76.4 ± 6.8 years; 62.3% men). They were categorized into three groups: 26 (20.0%) in EVCD Stage 1, 66 (50.8%) in Stage 2, and 48 (29.2%) in Stage 3/4. The endpoint occurred in 54 (41.5%) patients during a median follow-up of 3.2 years (interquartile range, 1.4-5.1). Multivariate analysis indicated EVCD Stage 3/4 was significantly associated with the endpoint (hazard ratio 2.784; 95% confidence interval 1.197-6.476; P = .017) compared to Stage 1, while Stage 2 did not (hazard ratio 1.340; 95% confidence interval .577-3.115; P = .500). CONCLUSION: The EVCD staging system may aid in the risk stratification of patients with moderate AS and reduced LVEF.


Asunto(s)
Estenosis de la Válvula Aórtica , Volumen Sistólico , Humanos , Masculino , Femenino , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/complicaciones , Anciano , Volumen Sistólico/fisiología , Pronóstico , Ecocardiografía/métodos , Medición de Riesgo/métodos , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Función Ventricular Izquierda/fisiología , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Disfunción Ventricular Izquierda/fisiopatología , Disfunción Ventricular Izquierda/etiología , Disfunción Ventricular Izquierda/diagnóstico por imagen , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/fisiopatología
5.
Eur Heart J Imaging Methods Pract ; 2(2): qyae048, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-39045467

RESUMEN

Aims: Cardiac power output (CPO) measures cardiac performance, and its prognostic significance in heart failure with preserved ejection fraction (EF) has been previously reported. However, the effectiveness of CPO in risk stratification of patients with valvular heart disease and post-operative valvular disease has not been reported. We aimed to determine the association between CPO and clinical outcomes in patients with preserved left ventricular (LV) EF after transcatheter aortic valve implantation (TAVI). Methods and results: This retrospective observational study included 1047 consecutive patients with severe aortic stenosis after TAVI. All patients were followed up for all-cause mortality and hospitalization for HF. CPO was calculated as 0.222 × cardiac output × mean blood pressure (BP)/LV mass, where 0.222 was the conversion constant to W/100 g of the LV myocardium. CPO was assessed using transthoracic echocardiography at discharge after TAVI. Of the 1047 patients, 253 were excluded following the exclusion criteria, including those with low LVEF, and 794 patients (84.0 [80.0-88.0] years; 35.8% male) were included in this study. During a median follow-up period of 684 (237-1114) days, the composite endpoint occurred in 196 patients. A dose-dependent association was observed between the CPO levels and all-cause mortality. Patients in the lowest CPO tertile had significantly lower event-free survival rates (log-rank test, P = 0.043). Multivariate Cox regression analysis showed that CPO was independently associated with adverse outcomes (hazard ratio = 0.561, P = 0.020). CPO provided an incremental prognostic effect in the model based on clinical and echocardiographic markers (P = 0.034). Conclusion: CPO is independently and incrementally associated with adverse outcomes in patients with preserved LVEF following TAVI.

6.
J Arrhythm ; 40(3): 647-650, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38939798

RESUMEN

We report the behavior of OptiVol2 fluid index (OVFI2) and intrathoracic impedance on remote monitoring before the appearance of signs of infection. A sustained rise in OVFI2 early after implantation reflects peri-device fluid retention.

8.
Cardiovasc Interv Ther ; 39(3): 241-251, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38642290

RESUMEN

Despite guideline-based recommendation of the interchangeable use of instantaneous wave-free ratio (iFR) and fractional flow reserve (FFR) to guide revascularization decision-making, iFR/FFR could demonstrate different physiological or clinical outcomes in some specific patient or lesion subsets. Therefore, we sought to investigate the impact of difference between iFR and FFR-guided revascularization decision-making on clinical outcomes in patients with left main disease (LMD). In this international multicenter registry of LMD with physiological interrogation, we identified 275 patients in whom physiological assessment was performed with both iFR/FFR. Major adverse cardiovascular event (MACE) was defined as a composite of death, non-fatal myocardial infarction, and ischemia-driven target lesion revascularization. The receiver-operating characteristic analysis was performed for both iFR/FFR to predict MACE in respective patients in whom revascularization was deferred and performed. In 153 patients of revascularization deferral, MACE occurred in 17.0% patients. The optimal cut-off values of iFR and FFR to predict MACE were 0.88 (specificity:0.74; sensitivity:0.65) and 0.76 (specificity:0.81; sensitivity:0.46), respectively. The area under the curve (AUC) was significantly higher for iFR than FFR (0.74; 95%CI 0.62-0.85 vs. 0.62; 95%CI 0.48-0.75; p = 0.012). In 122 patients of coronary revascularization, MACE occurred in 13.1% patients. The optimal cut-off values of iFR and FFR were 0.92 (specificity:0.93; sensitivity:0.25) and 0.81 (specificity:0.047; sensitivity:1.00), respectively. The AUCs were not significantly different between iFR and FFR (0.57; 95%CI 0.40-0.73 vs. 0.46; 95%CI 0.31-0.61; p = 0.43). While neither baseline iFR nor FFR was predictive of MACE in patients in whom revascularization was performed, iFR-guided deferral seemed to be safer than FFR-guided deferral.


Asunto(s)
Enfermedad de la Arteria Coronaria , Reserva del Flujo Fraccional Miocárdico , Humanos , Reserva del Flujo Fraccional Miocárdico/fisiología , Masculino , Femenino , Anciano , Enfermedad de la Arteria Coronaria/fisiopatología , Enfermedad de la Arteria Coronaria/cirugía , Enfermedad de la Arteria Coronaria/diagnóstico , Persona de Mediana Edad , Angiografía Coronaria , Sistema de Registros , Revascularización Miocárdica/métodos , Curva ROC , Cateterismo Cardíaco/métodos , Estudios Retrospectivos
9.
J Clin Med ; 13(7)2024 Mar 24.
Artículo en Inglés | MEDLINE | ID: mdl-38610628

RESUMEN

Background: Transthoracic echocardiography (TTE) is the gold standard modality for evaluating cardiac morphology, function, and hemodynamics in clinical practice. While artificial intelligence (AI) is expected to contribute to improved accuracy and is being applied clinically, its impact on daily clinical practice has not been fully evaluated. Methods: We retrospectively examined 30 consecutive patients who underwent AI-equipped TTE at a single institution. All patients underwent manual and automatic measurements of TTE parameters using the AI-equipped TTE. Measurements were performed by three sonographers with varying experience levels: beginner, intermediate, and expert. Results: A comparison between the manual and automatic measurements assessed by the experts showed extremely high agreement in the left ventricular (LV) filling velocities (E wave: r = 0.998, A wave: r = 0.996; both p < 0.001). The automated measurements of LV end-diastolic and end-systolic diameters were slightly smaller (-2.41 mm and -1.19 mm) than the manual measurements, although without significant differences, and both methods showing high agreement (r = 0.942 and 0.977, both p < 0.001). However, LV wall thickness showed low agreement between the automated and manual measurements (septum: r = 0.670, posterior: r = 0.561; both p < 0.01), with automated measurements tending to be larger. Regarding interobserver variabilities, statistically significant agreement was observed among the measurements of expert, intermediate, and beginner sonographers for all the measurements. In terms of measurement time, automatic measurement significantly reduced measurement time compared to manual measurement (p < 0.001). Conclusions: This preliminary study confirms the accuracy and efficacy of AI-equipped TTE in routine clinical practice. A multicenter study with a larger sample size is warranted.

11.
Eur Heart J Open ; 4(2): oeae018, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38529170

RESUMEN

Aims: Current evidence on the prognostic value of exercise stress echocardiography (ESE) in asymptomatic patients with low-gradient severe aortic stenosis (AS) is limited. Therefore, this study aimed to elucidate its prognostic implications for patients with low-gradient severe AS and determine the added value of ESE in risk stratification for this population. Methods and results: This retrospective observational study included 122 consecutive asymptomatic patients with either moderate [mean pressure gradient (MPG) < 40 mmHg and aortic valve area (AVA) 1.0-1.5 cm2] or low-gradient severe (MPG < 40 mmHg and AVA < 1.0 cm2) AS and preserved left ventricular ejection fraction (≥50%) who underwent ESE. All patients were followed up for AS-related events. Of 143 patients, 21 who met any exclusion criteria, including early interventions, were excluded, and 122 conservatively managed patients [76.5 (71.0-80.3) years; 48.3% male] were included in this study. During a median follow-up period of 989 (578-1571) days, 64 patients experienced AS-related events. Patients with low-gradient severe AS had significantly lower event-free survival rates than those with moderate AS (log-rank test, P < 0.001). Multivariable Cox regression analysis showed that the mitral E/e' ratio during exercise was independently associated with AS-related events (hazard ratio = 1.075, P < 0.001) in patients with low-gradient severe AS. Conclusion: This study suggests that asymptomatic patients with low-gradient severe AS have worse prognoses than those with moderate AS. Additionally, the mitral E/e' ratio during exercise is a useful parameter for risk stratification in patients with low-gradient severe AS.

12.
Circ J ; 88(7): 1147-1154, 2024 06 25.
Artículo en Inglés | MEDLINE | ID: mdl-38311419

RESUMEN

BACKGROUND: High shock impedance is associated with conversion failure among patients with subcutaneous implantable cardioverter defibrillators (S-ICD). Currently, there is no preoperative assessment method for predicting high shock impedance. This study examined the efficacy of chest computed tomography (CT) as a preoperative evaluation tool to assess the shock impedance of S-ICDs. METHODS AND RESULTS: The amount of adipose tissue adjacent to the device and anteroposterior diameter at the basal heart region were measured preoperatively using chest CT. We examined the correlation between these measurements and shock impedance at the conversion test. We enrolled 43 patients with S-ICDs (mean [±SD] age 54±15 years; body mass index 23±4 kg/m2; PRAETORIAN score 30-270 points; amount of adipose tissue 1,250±716 cm3), who underwent intraoperative conversion tests by inducing ventricular fibrillation, which was terminated with a 65-J shock. A sufficient concordance correlation coefficient was observed between the shock impedance and the amount of adipose tissue (r=0.616, P<0.01) and anteroposterior diameter (r=0.645, P<0.01). In multiple regression analysis, the amount of adipose tissue (ß=0.439, P=0.009) and anteroposterior diameter (ß=0.344, P=0.038) were identified as independent predictive factors of shock impedance. CONCLUSIONS: The preoperative CT-measured amount of adipose tissue and basal heart anteroposterior diameter are independent predictors of shock impedance. These parameters may be more accurate in identifying higher shock impedance in patients with S-ICDs.


Asunto(s)
Desfibriladores Implantables , Impedancia Eléctrica , Tomografía Computarizada por Rayos X , Humanos , Persona de Mediana Edad , Masculino , Femenino , Anciano , Adulto , Tejido Adiposo/diagnóstico por imagen , Fibrilación Ventricular/terapia , Fibrilación Ventricular/diagnóstico por imagen , Fibrilación Ventricular/fisiopatología , Valor Predictivo de las Pruebas
13.
JACC Case Rep ; 29(4): 102216, 2024 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-38379648

RESUMEN

A 70-year-old patient with paroxysmal atrial fibrillation underwent left atrial appendage closure. The patient experienced transient hypotension during device implantation. The procedure was abandoned because of ST-T-wave changes on electrocardiography and elevated coronary flow velocity on transesophageal echocardiography, which indicated that the device caused coronary artery compression.

14.
Circ J ; 88(9): 1360-1371, 2024 Aug 23.
Artículo en Inglés | MEDLINE | ID: mdl-38220206

RESUMEN

BACKGROUND: This study aimed to clarify the effects of exercise-based cardiac rehabilitation (CR) on patients with heart failure. METHODS AND RESULTS: Patients were divided into groups according to intervention duration (<6 and ≥6 months). We searched for studies published up to July 2023 in Embase, MEDLINE, PubMed, and the Cochrane Library, without limitations on data, language, or publication status. We included randomized controlled trials comparing the efficacy of CR and usual care on mortality, prehospitalization, peak oxygen uptake (V̇O2), and quality of life. Seventy-two studies involving 8,495 patients were included in this review. It was found that CR reduced the risk of rehospitalization for any cause (risk ratio [RR] 0.80; 95% confidence interval [CI] 0.70-0.92) and for heart failure (RR 0.88; 95% CI 0.78-1.00). Furthermore, CR was found to improve exercise tolerance (measured by peak V̇O2and the 6-min walk test) and quality of life. A subanalysis performed based on intervention duration (<6 and ≥6 months) revealed a similar trend. CONCLUSIONS: Our meta-analysis showed that although CR does not reduce mortality, it is effective in reducing rehospitalization rates and improving exercise tolerance and quality of life, regardless of the intervention duration.


Asunto(s)
Rehabilitación Cardiaca , Terapia por Ejercicio , Tolerancia al Ejercicio , Insuficiencia Cardíaca , Calidad de Vida , Humanos , Insuficiencia Cardíaca/rehabilitación , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/fisiopatología , Rehabilitación Cardiaca/métodos , Enfermedad Crónica , Masculino , Femenino , Anciano , Readmisión del Paciente/estadística & datos numéricos , Factores de Tiempo , Resultado del Tratamiento , Persona de Mediana Edad , Ensayos Clínicos Controlados Aleatorios como Asunto , Consumo de Oxígeno
15.
J Gen Fam Med ; 25(1): 53-61, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38240001

RESUMEN

Background: Coronavirus disease 2019 (COVID-19) sequelae, also known as long COVID, can present with various symptoms. Among these symptoms, autonomic dysregulation, particularly postural orthostatic tachycardia syndrome (POTS), should be evaluated. However, previous studies on the treatment of POTS complicated by COVID-19 are lacking. Therefore, this study aimed to investigate the treatment course of long COVID complicated by POTS. Methods: The medical records of patients who complained of fatigue and met the criteria for POTS diagnosis were reviewed. We evaluated the treatment days, methods and changes in fatigue score, changes in heart rate on the Schellong test, and social situation at the first and last visits. Results: Thirty-two patients with long COVID complicated by POTS were followed up (16 males; median age: 28 years). The follow-up period was 159 days, and the interval between COVID-19 onset and initial hospital attendance was 97 days. Some patients responded to ß-blocker therapy. Many patients had psychiatric symptoms that required psychiatric intervention and selective serotonin reuptake inhibitor prescription. Changes in heart rate, performance status, and employment/education status improved from the first to the last visit. These outcomes were believed to be because of the effects of various treatment interventions and spontaneous improvements. Conclusions: Our study suggests that the condition of 94% of patients with POTS complicated by long COVID will improve within 159 days. Therefore, POTS evaluation should be considered when patients with long COVID complain of fatigue, and attention should be paid to psychological symptoms and the social context.

16.
Cardiovasc Revasc Med ; 58: 68-76, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37500393

RESUMEN

BACKGROUND: Aortic stenosis (AS) and chronic kidney disease (CKD) can coexist. Repeat exposure to contrast media in patients undergoing transcatheter aortic valve implantation (TAVI) has latent mortality risks and increased risk for acute kidney injury. We aimed to assess our "zero-contrast TAVI" protocol for patients with advanced CKD. METHODS: Consecutive patients with severe AS who underwent TAVI at a single center registry were enrolled. Zero-contrast TAVI group included patients who underwent TAVI without contrast and who had an estimated glomerular filtration rate <30 mL/min/1.73 m2. Conventional TAVI group included patients who underwent the regular TAVI procedure. Patients using balloon-expandable valves via transfemoral approach were analyzed. Baseline clinical and procedural characteristics and clinical outcomes were compared between two groups. The primary outcome was early safety as defined by Valve Academic Research Consortium Criteria. Secondary outcomes included the presence of severe prosthesis-patient mismatch, moderate or greater perivalvular leakage, and requirement for new dialysis (within 3 months). RESULTS: A total of 520 patients were analyzed. Among these, 32 (6 %) underwent zero-contrast TAVI and 488 (94 %) conventional TAVI. In the zero-contrast TAVI group, 12 patients (37.5 %) had to use 20.7 (11.0-31.2) mL of contrast media. There were no significant differences in the primary and secondary outcomes between zero-contrast TAVI and conventional TAVI groups (78.1 % vs. 86.8 %, P = 0.184 and 9.4 % vs. 8.1 %, P = 0.738 for the primary and secondary outcomes, respectively). CONCLUSIONS: Zero-contrast TAVI is feasible, safe, and effective in patients with AS and stage 4 CKD.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Insuficiencia Renal Crónica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Estudios de Factibilidad , Medios de Contraste/efectos adversos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Insuficiencia Renal Crónica/complicaciones , Insuficiencia Renal Crónica/diagnóstico , Insuficiencia Renal Crónica/terapia , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Resultado del Tratamiento
17.
J Cardiol ; 83(3): 169-176, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37543193

RESUMEN

BACKGROUND: Transcatheter aortic valve replacement (TAVR) for severe symptomatic aortic stenosis (AS) does not benefit all patients. We performed a prospective multicenter study to investigate the cost-effectiveness of TAVR in a Japanese cohort. METHODS AND RESULTS: We prospectively enrolled 110 symptomatic patients with severe AS who underwent TAVR from five institutions. The quality of life measurement (QOL) was performed for each patient before and at 6 months after TAVR. Patients without an improvement in QOL at 6 months after TAVR were defined as non-responders. Pre-TAVR higher QOL, higher clinical frailty scale predicted the non-responders. Three models, 1) conservative treatment for all patients strategy, 2) TAVR for all patients strategy, and 3) TAVR for a selected patient strategy who is expected to be a responder, were simulated. Lifetime cost-effectiveness was estimated using incremental cost-effectiveness ratio (ICER) and cost per quality-adjusted life-year (QALY) gained. In comparison to conservative therapy for all patients, ICER was estimated to be 5,765,800 yen/QALY for TAVR for all patients and 2,342,175 yen/QALY for TAVR for selected patient strategy patients, which is less than the commonly accepted ICER threshold of 5,000,000 yen/QALY. CONCLUSIONS: TAVR for selected patient strategy model is more cost-effective than TAVR for all patient strategy without reducing QOL in the Japanese healthcare system. TAVR for selected patient strategy has potential benefit for optimizing the TAVR treatment in patients with high frailty and may direct our resources toward beneficial interventions.


Asunto(s)
Estenosis de la Válvula Aórtica , Fragilidad , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Calidad de Vida , Análisis Costo-Beneficio , Estudios Prospectivos , Fragilidad/etiología , Estenosis de la Válvula Aórtica/etiología , Índice de Severidad de la Enfermedad , Resultado del Tratamiento , Válvula Aórtica/cirugía , Factores de Riesgo
18.
Echocardiography ; 41(1): e15712, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37937359

RESUMEN

BACKGROUNDS: There are limited data on the clinical relevance of transvalvular flow rate (Qmean ) at rest (Qrest) and at peak stress (Qstress ) during dobutamine stress echocardiography (DSE) in patients with low-gradient severe aortic stenosis (LG-SAS). METHODS: We retrospectively analyzed the clinical data of patients with LG-SAS who underwent DSE. LG-SAS was defined as an aortic valve (AV) area index of < .6 cm2 /m2 and a mean AV pressure gradient (AVPG) of < 40 mm Hg. The primary endpoint included all-cause death and heart failure hospitalization. RESULTS: Of 100 patients (mean age 79.5 ± 7.3 years; men, 45.0%; resting left ventricular ejection fraction [LVEF] 52.1% ± 15.9%; resting stroke volume index 35.8 ± 7.7 mL/m2 ; Qrest 171.8 ± 34.9 mL/s), the primary endpoint occurred in 51 patients during a median follow-up of 2.84 (interquartile range 1.01-5.21) years. When the study patients were divided into three subgroups based on Qrest and Qstress , the multivariate analysis showed that Qrest < 200 mL/s and Qstress ≥200 mL/s (hazard ratio 3.844; 95% confidence interval 1.143-12.930; p = .030), as well as Qrest and Qstress < 200 mL/s (hazard ratio 9.444; 95% confidence interval 2.420-36.850; p = .001), were significantly associated with unfavorable outcomes with Qrest and Qstress ≥200 mL/s as a reference after adjusting for resting LVEF, resting mean AVPG, chronic kidney disease, New York Heart Association functional class III/IV, and AV replacement. CONCLUSIONS: Flow conditions based on the combination of Qrest and Qstress are helpful for risk stratification in LG-SAS patients.


Asunto(s)
Estenosis de la Válvula Aórtica , Función Ventricular Izquierda , Masculino , Humanos , Anciano , Anciano de 80 o más Años , Volumen Sistólico , Pronóstico , Ecocardiografía de Estrés , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estudios Retrospectivos , Válvula Aórtica/diagnóstico por imagen , Índice de Severidad de la Enfermedad
19.
Circ J ; 88(4): 531-538, 2024 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-38008428

RESUMEN

BACKGROUND: The MitraClip G4 system is a new iteration of the transcatheter edge-to-edge repair system. We assessed the impact of the G4 system on routine practice and outcomes in secondary mitral regurgitation (2°MR).Methods and Results: Consecutive patients with 2°MR treated with either the MitraClip G2 (n=89) or G4 (n=63) system between 2018 and 2021 were included. Baseline characteristics, procedures, and outcomes were compared. Inverse probability of treatment weighting and Cox regression were used to adjust for baseline differences. Baseline characteristics were similar, except for a lower surgical risk in the G4 group (Society of Thoracic Surgeons Predicted Risk of Mortality ≥8: 38.1% vs. 56.2%; P=0.03). In the G4 group, more patients had short (≤2 mm) coaptation length (83.7% vs. 54.0%; P<0.001) and fewer clips were used (17.5% vs. 36.0%; P=0.02). Acceptable MR reduction was observed in nearly all patients, with no difference between the G4 and G2 groups (100% vs. 97.8%, respectively; P=0.51). The G4 group had fewer patients with high transmitral gradients (>5mmHg; 3.3% vs. 13.6%; P=0.03). At 1 year, there was no significant difference between groups in the composite endpoint (death or heart failure rehospitalization) after baseline adjustment (10.5% vs. 20.2%; hazard ratio 0.39; 95% confidence interval 0.11-1.32; P=0.13). CONCLUSIONS: The G4 system achieved comparable device outcomes to the early-generation G2, despite treating more challenging 2°MR with fewer clips.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Resultado del Tratamiento , Modelos de Riesgos Proporcionales , Cateterismo Cardíaco
20.
Cardiovasc Interv Ther ; 39(1): 74-82, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37938532

RESUMEN

The safety and feasibility are still not well known for exercise-induced mitral regurgitation (MR). This study is aimed to assess and compare the hemodynamic and symptomatic changes in patients with significant secondary MR during exercise stress echocardiography (ESE) before and after transcatheter edge-to-edge repair (TEER). The study included a total of 15 patients with secondary MR who underwent ESE before and after TEER using the MitraClip system (Abbott, Abbott Park, IL, USA). Echocardiographic data of ESE were collected both before the procedure and during the follow-up visit at 3 months. During the one-year postoperative observation period, the rate of readmission due to heart failure was 13% (n = 2), with no recorded fatalities. Although no significant differences of ESE data were observed in exercise-induced pulmonary hypertension or cardiac output before and after the repair, the severity of MR was significantly improved after the procedure, both at rest (2 [2-3] vs. 1 [1-2], p = 0.0125) and during ESE (3 [3-3] vs. 1 [1-1], p < 0.0001). Furthermore, the New York Heart Association Functional Classification was improved (3 [3-3] vs. 1 [1-1], p < 0.0001) after treatment. For a supplemental analysis, MR during ESE was significantly improved not only in cases with atrial secondary MR but also in ventricular secondary MR. Transcatheter edge-to-edge repair for exercise-induced MR resulted in a significant improvement in postoperative MR severity and subjective symptoms. These results are novel, as they have not been extensively reported previously, particularly among Japanese patients.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Ecocardiografía de Estrés , Resultado del Tratamiento , Insuficiencia de la Válvula Mitral/diagnóstico , Insuficiencia de la Válvula Mitral/cirugía , Ecocardiografía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Cateterismo Cardíaco
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...