Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros













Base de datos
Intervalo de año de publicación
1.
J Clin Med ; 13(11)2024 May 27.
Artículo en Inglés | MEDLINE | ID: mdl-38892842

RESUMEN

Background/Objectives: Cervical spine fractures in ankylosing spondylitis (AS) are characterized as highly unstable fractures posing an elevated risk of neurological deficit and a significantly elevated mortality rate. This study assesses the efficacy and safety of single-stage plate stabilization with ventral cement augmentation in treating subaxial cervical spine fractures in patients with AS. Methods: Over 86 months, 38 patients diagnosed with AS received ventral plate stabilization with cement augmentation after suffering unstable subaxial cervical fractures. No additional dorsal stabilization was used in any of these surgeries. Results: There were no complications as a result of cement leakage. During the follow-up period, screw loosening and implant displacement were documented in two out of 38 cases. At the time of data analysis, 17 patients who had undergone treatment had died, representing 44.7% of the total cases. Seven patients died within 1 month, two patients died within 6 months, four patients died within 1 year, and four patients died after 1 year. Conclusions: Our study shows that a single-stage anterior screw and plate fixation of the cervical spine with cement augmentation could be a feasible and effective method to treat cervical spine fractures in patients with AS.

2.
J Clin Med ; 13(11)2024 May 29.
Artículo en Inglés | MEDLINE | ID: mdl-38892910

RESUMEN

Background: Psoas muscle abscess (PMA) is an uncommon yet severe condition characterized by diagnostic and therapeutic challenges due to its varied etiology and nonspecific symptoms. This study aimed to evaluate the effectiveness and accuracy of various imaging techniques used in the image-guided percutaneous drainage (PD) of PMA. Methods: A systematic review was conducted following the PRISMA guidelines. We searched PubMed, Google Scholar, and Science Direct for studies published in English from 1998 onwards that reported on the use of PD in treating PMA, detailing outcomes and complications. Imaging modalities guiding PD were also examined. Results: We identified 1570 articles, selecting 39 for full review. Of these, 23 met the inclusion criteria; 19 were excluded due to unspecified PMA, absence of imaging guidance for PD, or inconclusive results. Eleven studies utilized computed tomography (CT) for PD, with six also using magnetic resonance imaging (MRI). Ten studies implemented ultrasound (US)-guided PD; variations in diagnostic imaging included combinations of US, CT, and MRI. A mixed approach using both CT and US was reported in two articles. Most studies using CT-guided PD showed complete success, while outcomes varied among those using US-guided PD. No studies employed MRI-guided PD. Conclusions: This review supports a multimodal approach for psoas abscess management, using MRI for diagnosis and CT for drainage guidance. We advocate for Cone Beam CT (CBCT)-MRI fusion techniques with navigation systems to enhance treatment precision and outcomes, particularly in complex cases with challenging abscess characteristics.

3.
J Clin Med ; 13(11)2024 Jun 06.
Artículo en Inglés | MEDLINE | ID: mdl-38893058

RESUMEN

Background/Objectives: Osteoporotic vertebral fractures (OVFs) significantly impair quality of life. This study evaluates the impact of STIR sequence MR imaging on clinical decision-making for treating OVFs, mainly focusing on how MRI findings influence treatment modifications compared to those based solely on CT scans. Methods: This retrospective analysis reviewed cases from the Manninger Jeno National Traumatology Institute over ten years, where patients with suspected OVFs underwent CT and STIR sequence MR imaging. The study examined changes in treatment plans initiated by MRI findings. The diagnostic effectiveness of MRI was compared against CT in terms of sensitivity, specificity, and the ability to influence clinical treatment paths. Results: MRI detected 1.65 times more fractures than CT scans. MRI influenced treatment adjustments in 67% of cases, leading to significant changes from conservative-conservative, conservative-surgery, and surgery-surgery based on fracture characterizations provided by MRI. Conclusions: This study demonstrates that integrating STIR sequence MR imaging into the diagnostic pathway for OVFs significantly enhances the accuracy of fracture detection and profoundly impacts treatment decisions. The ability of MRI to reveal specific fracture features that are not detectable by CT scans supports its importance in the clinical evaluation of OVFs, suggesting that MRI should be incorporated more into diagnostic protocols to improve patient management and outcomes. The findings advocate for further research to establish STIR MRI as a standard osteoporosis management tool and explore its long-term benefits in preventing secondary fractures.

4.
Clin Hemorheol Microcirc ; 87(1): 27-37, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38250764

RESUMEN

BACKGROUND: Arteriovenous malformations (AVMs) are vascular anomalies characterized by abnormal shunting between arteries and veins. The progression of the AVMs and their hemodynamic and rheological relations are poorly studied, and there is a lack of a feasible experimental model. OBJECTIVE: To establish a model that cause only minimal micro-rheological alterations, compared to other AV models. METHODS: Sixteen female Sprague Dawley rats were randomly divided into control and AVM groups. End-to-end anastomoses were created between the saphenous veins and arteries to mimic AVM nidus. Hematological and hemorheological parameters were analyzed before surgery and on the 1st, 3rd, 5th, 7th, 9th, and 12th postoperative weeks. RESULTS: Compared to sham-operated Control group the AVM group did not show important alterations in hematological parameters nor in erythrocyte aggregation and deformability. However, slightly increased aggregation and moderately decreased deformability values were found, without significant differences. The changes normalized by the 12th postoperative week. CONCLUSIONS: The presented rat model of a small-caliber AVM created on saphenous vessels does not cause significant micro-rheological changes. The alterations found were most likely related to the acute phase reactions and not to the presence of a small-caliber shunt. The model seems to be suitable for further studies of AVM progression.


Asunto(s)
Malformaciones Arteriovenosas , Modelos Animales de Enfermedad , Ratas Sprague-Dawley , Animales , Ratas , Femenino , Malformaciones Arteriovenosas/patología , Vena Safena/patología , Hemorreología , Derivación Arteriovenosa Quirúrgica , Deformación Eritrocítica , Agregación Eritrocitaria
5.
Cancers (Basel) ; 15(24)2023 Dec 07.
Artículo en Inglés | MEDLINE | ID: mdl-38136290

RESUMEN

Spinal metastatic tumors are common and often cause debilitating symptoms. Image-guided percutaneous thermal ablation (IPTA) has gained significant recognition in managing spinal column tumors due to its exceptional precision and effectiveness. Conventional guidance modalities, including computed tomography, fluoroscopy, and ultrasound, have been important in targeting spinal column tumors while minimizing harm to adjacent critical structures. This study presents a novel approach utilizing a fusion of cone beam computed tomography with magnetic resonance imaging to guide percutaneous thermal ablation for four patients with secondary spinal column tumors. The visual analog scale (VAS) evaluated the procedure effectiveness during an 18-month follow-up. Percutaneous vertebroplasty was performed in two cases, and a thermostat was used during all procedures. Imaging was performed using the Stealth Station navigation system Spine 8 (SSS8) and a 1.5T MRI machine. The fusion of CBCT with MRI allowed for precise tumor localization and guidance for thermal ablation. Initial results indicate successful tumor ablation and symptom reduction, emphasizing the potential of CBCT-MRI fusion in spinal column tumor management. This innovative approach is promising in optimizing therapy for secondary spinal column tumors. Further studies are necessary to validate its efficacy and applicability.

6.
Biomedicines ; 11(11)2023 Nov 04.
Artículo en Inglés | MEDLINE | ID: mdl-38001970

RESUMEN

Arteriovenous malformation (AVM) is an anomaly of blood vessel formation. Numerous models have been established to understand the nature of AVM. These models have limitations in terms of the diameter of the vessels used and the impact on the circulatory system. Our goal was to establish an AVM model that does not cause prompt and significant hemodynamic and cardiac alterations but is feasible for follow-up of the AVM's progression. Sixteen female rats were randomly divided into sham-operated and AVM groups. In the AVM group, the saphenous vein and artery were interconnected using microsurgical techniques. The animals were followed up for 12 weeks. Anastomosis patency and the structural and hemodynamic changes of the heart were monitored. The hearts and vessels were histologically analyzed. During the follow-up period, shunts remained unobstructed. Systolic, diastolic, mean arterial pressure, and heart rate values slightly and non-significantly decreased in the AVM group. Echocardiogram results indicated minor systolic function impact, with slight and insignificant changes in aortic pressure and blood velocity, and minimal left ventricular wall enlargement. The small-caliber saphenous AVM model does not cause acute hemodynamic changes. Moderate but progressive alterations and venous dilatation confirmed AVM-like features. The model seems to be suitable for studying further the progression, enlargement, or destabilization of AVM.

7.
Front Physiol ; 11: 616528, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33391035

RESUMEN

Introduction: In case of kidney failure, hemodialysis is the primary kidney replacement technique. Several vascular access methods used for the therapy, one of which is the arterio-venous fistula (AVF). In the AVF, the blood flow is altered, which can elevate the mechanical stress on the red blood cells (RBCs). This can affect the RBC hemorheological properties, and it can further cause systemic changes. To lower the turbulence and shear stress, we performed a loop-shaped arterio-arterial venous interposition graft (loop-shaped graft) to compare its effect to the conventional AVF. Materials and Methods: Thirty male Wistar were used (permission registration Nr.: 25/2016/UDCAW). The animals were randomly divided into sham-operated, AVF, and loop groups (n = 10/each). The superficial inferior epigastric vein (SIEV) was used to create the AVF and the loop-shaped graft. Blood samples were taken before/after the surgery and at the 1st, 3rd, and 5th postoperative weeks. We measured hemorhelogical, hematological, and blood gas parameters. The microcirculation of the hind limbs was also monitored using Laser Doppler fluxmetry. Results: Hematocrit, RBC count, and hemoglobin decreased by the 1st postoperative week. The erythrocyte aggregation values significantly increased in the fistula group by the 5th week (6.43 ± 2.31 vs. 13.60; p < 0.0001; vs. before operation). At the postoperative 1st week in the loop group, the values showed a significant decrease in RBC deformability. During the maturation period, dominantly at the 5th week, all values were normalized. The operated hind limb's skin microcirculation significantly increased in the sham and loop group by the 1st week (39 ± 10.57 vs. 73.93 ± 1.97 BFU, p < 0.01). This increase wasn't observed in the fistula group probably due to a steal-effect. Conclusion: Unlike in the loop group, in the presence of the fistula, several rheological parameters have changed. The loop-shaped graft had only minimal impact on micro-rheological parameters.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA